Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Street, 060021 Bucharest-6, Romania
Dr. Damaris Gheorghe
Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Street, 060021 Bucharest-6, Romania
Vitamins are one of the most essential organic compounds that are necessary for the human body, in order to develop and grow in a healthy way. The aim of this mini-review is to bring together a series of electrochemical sensors (voltametric and amperometric) developed for the determination of vitamins from the families of B, D and K in biological, pharmaceutical or food-related samples. For this mini-review, 16 articles published between 2016 and 2021 were taken into consideration.
Bladder cancer is one of the most common urologic malignancies, which is more frequent in men than in women. The early diagnosis for this type of cancer still remains a challenge, therefore, the development of a fast screening test for whole blood and tumor tissue samples may save lives. Four biomarkers, p53, E-cadherin, bladder tumor antigen (BTA), and hyaluronic acid were considered for the screening tests using stochastic needle sensors. Three stochastic needle sensors, based on graphite powder and modified with three types of chitosan, were designed and characterized for the screening test. The proposed sensors showed low limits of quantification, and high sensitivity and selectivity levels. The recoveries of p53, E-cadherin, BTA, and hyaluronic acid in whole blood samples and tissue samples were higher than 95.00% with a relative standard deviation lower than 1.00%.
14 July 2022 in Analytical and Bioanalytical Chemistry
Stochastic biosensors based on N- and S-doped graphene modified with hemin or α-hemolysin contributed to establishing the metabolomics of gastric cancer by performing the enantioanalysis of aspartic acid in different biological samples.
Two stochastic sensors were characterized and validated for the molecular identification and quantification of MLH1, MSH2, MSH6, PMS2 and KRAS in biological samples using two types of doped-graphene modified with maltodextrin. When a potential of 125 mV vs. Ag/AgCl was applied, the two stochastic sensors recorded extremely low limits of determination (fg mL−1 magnitude order) and wide linear concentration ranges, which enabled the molecular identification and quantification of MLH1, MSH2, MSH6, PMS2 and KRAS in healthy individuals and patients with gastric or colon cancer. The recoveries of MLH1, MSH2, MSH6, PMS2 and KRAS in whole blood, saliva, urine and tumoral tissue samples exceeded 98.00% with a relative standard deviation of less than 1.00%.
Vitamins are essential for sustaining daily activities and perform crucial roles in metabolism, such as preventing vascular events and delaying the development of diabetic nephropathy. The ultrasensitive assessment of thiamine in foods is required for food quality evaluation. A mini-platform utilizing two 3D sensors based on nanographene and gold nanoparticles paste modified with protoporphyrin IX and protoporphyrin IX cobalt chloride is proposed for the detection of thiamine in blueberry syrup, multivitamin tablets, water, and a biological sample (urine). Differential pulse voltammetry was utilized for the characterization and validation of the suggested sensors. The sensor modified with protoporphyrin IX has a detection limit of 3.0 × 10−13 mol L−1 and a quantification limit of 1.0 × 10−12 mol L−1, whereas the sensor modified with protoporphyrin IX cobalt chloride has detection and quantification limits of 3.0 × 10−12 and 1.0 × 10−11 mol L−1, respectively. High recoveries (values greater than 95.00%) and low RSD (%) values (less than 5.00%) are recorded for both 3D sensors when used for the determination of thiamine in blueberry syrup, multivitamin tablets, water, and urine, demonstrating the 3D sensors’ and suggested method’s high reliability.