David Atienza

Prof. David Atienza

EPFL, Embedded Systems Laboratory (ESL), School of Engineering, Institute of EE
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2011 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
HMHossein Mamaghanian
Hossein Mamaghanian
NKNadia Khaled
Nadia Khaled
David AtienzaDavid Atienza
David Atienza
PVPierre Vandergheynst
Pierre Vandergheynst
Wireless body sensor networks (WBSN) hold the promise to be a key enabling information and communications technology for next-generation patient-centric telecardiology or mobile cardiology solutions. Through enabling continuous remote cardiac monitoring, they have the potential to achieve improved personalization and quality of care, increased ability of prevention and early diagnosis, and enhanced patient autonomy, mobility, and safety. However, state-of-the-art WBSN-enabled ECG monitors still fall short of the required functionality, miniaturization, and energy efficiency. Among others, energy efficiency can be improved through embedded ECG compression, in order to reduce airtime over energy-hungry wireless links. In this paper, we quantify the potential of the emerging compressed sensing (CS) signal acquisition/compression paradigm for low-complexity energy-efficient ECG compression on the state-of-the-art Shimmer WBSN mote. Interestingly, our results show that CS represents a competitive alternative to state-of-the-art digital wavelet transform (DWT)-based ECG compression solutions in the context of WBSN-based ECG monitoring systems. More specifically, while expectedly exhibiting inferior compression performance than its DWT-based counterpart for a given reconstructed signal quality, its substantially lower complexity and CPU execution time enables it to ultimately outperform DWT-based ECG compression in terms of overall energy efficiency. CS-based ECG compression is accordingly shown to achieve a 37.1% extension in node lifetime relative to its DWT-based counterpart for “good” reconstruction quality.

23 June 2021 in Scientific Data
Verified
Journal Article
Open access
PDF file
LOLara Orlandic
Lara Orlandic
TTTomás Teijeiro
Tomás Teijeiro
David AtienzaDavid Atienza
David Atienza
Cough audio signal classification has been successfully used to diagnose a variety of respiratory conditions, and there has been significant interest in leveraging Machine Learning (ML) to provide widespread COVID-19 screening. The COUGHVID dataset provides over 25,000 crowdsourced cough recordings representing a wide range of participant ages, genders, geographic locations, and COVID-19 statuses. First, we contribute our open-sourced cough detection algorithm to the research community to assist in data robustness assessment. Second, four experienced physicians labeled more than 2,800 recordings to diagnose medical abnormalities present in the coughs, thereby contributing one of the largest expert-labeled cough datasets in existence that can be used for a plethora of cough audio classification tasks. Finally, we ensured that coughs labeled as symptomatic and COVID-19 originate from countries with high infection rates. As a result, the COUGHVID dataset contributes a wealth of cough recordings for training ML models to address the world’s most urgent health crises.

1 November 2010
Verified
Conference Paper
Closed access
ASArvind Sridhar
Arvind Sridhar
AVAlessandro Vincenzi
Alessandro Vincenzi
MRMartino Ruggiero
Martino Ruggiero
TBThomas Brunschwiler
Thomas Brunschwiler
David AtienzaDavid Atienza
David Atienza
Three dimensional stacked integrated circuits (3D ICs) are extremely attractive for overcoming the barriers in interconnect scaling, offering an opportunity to continue the CMOS performance trends for the next decade. However, from a thermal perspective, vertical integration of high-performance ICs in the form of 3D stacks is highly demanding since the effective areal heat dissipation increases with number of dies (with hotspot heat fluxes up to 250 W/cm2) generating high chip temperatures. In this context, inter-tier integrated microchannel cooling is a promising and scalable solution for high heat flux removal. A robust design of a 3D IC and its subsequent thermal management depend heavily upon accurate modeling of the effects of liquid cooling on the thermal behavior of the IC during the early stages of design. In this paper we present 3D-ICE, a compact transient thermal model (CTTM) for the thermal simulation of 3D ICs with multiple inter-tier microchannel liquid cooling. The proposed model is compatible with existing thermal CAD tools for ICs, and offers significant speed-up (up to 975x) over a typical commercial computational fluid dynamics simulation tool while preserving accuracy (i.e., maximum temperature error of 3.4%). In addition, a thermal simulator has been built based on 3D-ICE, which is capable of running in parallel on multicore architectures, offering further savings in simulation time and demonstrating efficient parallelization of the proposed approach.

7 May 2018 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
GSGrégoire Surrel
Grégoire Surrel
AAAmir Aminifar
Amir Aminifar
FRFrancisco Rincon
Francisco Rincon
SMSrinivasan Murali
Srinivasan Murali
David AtienzaDavid Atienza
David Atienza
Obstructive Sleep Apnea (OSA) is one of the main under-diagnosed sleep disorder. It is an aggravating factor for several serious cardiovascular diseases, including stroke. There is, however, a lack of medical devices for long-term ambulatory monitoring of OSA since current systems are rather bulky, expensive, intrusive, and cannot be used for long-term monitoring in ambulatory settings. In this paper, we propose a wearable, accurate, and energy efficient system for monitoring obstructive sleep apnea on a long-term basis. As an embedded system for Internet of Things, it reduces the gap between home health-care and professional supervision. Our approach is based on monitoring the patient using a single-channel electrocardiogram signal. We develop an efficient time-domain analysis to meet the stringent resources constraints of embedded systems to compute the sleep apnea score. Our system, for a publicly available database (PhysioNet Apnea-ECG), has a classification accuracy of up to 88.2% for our new online and patient-specific analysis, which takes the distinct profile of each patient into account. While accurate, our approach is also energy efficient and can achieve a battery lifetime of 46 days for continuous screening of OSA.

9 July 2021 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
SBSaleh Baghersalimi
Saleh Baghersalimi
TTTomás Teijeiro
Tomás Teijeiro
David AtienzaDavid Atienza
David Atienza
AAAmir Aminifar
Amir Aminifar
Epilepsy is one of the most prevalent paroxystic neurological disorders. It is characterized by the occurrence of spontaneous seizures. About 1 out of 3 patients have drug-resistant epilepsy, thus their seizures cannot be controlled by medication. Automatic detection of epileptic seizures can substantially improve the patient’s quality of life. To achieve a high-quality model, we have to collect data from various patients in a central server. However, sending the patient’s raw data to this central server puts patient privacy at risk and consumes a significant amount of energy. To address these challenges, in this work, we have designed and evaluated a standard federated learning framework in the context of epileptic seizure detection using a deep learning-based approach, which operates across a cluster of machines. We evaluated the accuracy and performance of our proposed approach on the NVIDIA Jetson Nano Developer Kit based on the EPILEPSIAE database, which is one of the largest public epilepsy datasets for seizure detection. Our proposed framework achieved a sensitivity of 81.25%, a specificity of 82.00%, and a geometric mean of 81.62%. It can be implemented on embedded platforms that complete the entire training process in 1.86 hours using 344.34 mAh energy on a single battery charge. We also studied a personalized variant of the federated learning, where each machine is responsible for training a deep neural network (DNN) to learn the discriminative electrocardiography (ECG) features of the epileptic seizures of the specific person monitored based on its local data. In this context, the DNN benefitted from a well-trained model without sharing the patient’s raw data with a server or a central cloud repository. We observe in our results that personalized federated learning provides an increase in all the performance metric, with a sensitivity of 90.24%, a specificity of 91.58%, and a geometric mean of 90.90%.

1 April 2009
Verified
Conference Paper
Closed access
ACAyse K. Coskun
Ayse K. Coskun
JAJose Ayala
Jose Ayala
David AtienzaDavid Atienza
David Atienza
TRTajana Simunic Rosing
Tajana Simunic Rosing
YLYusuf Leblebici
Yusuf Leblebici
Technology scaling has caused the feature sizes to shrink continuously, whereas interconnects, unlike transistors, have not followed the same trend. Designing 3D stack architectures is a recently proposed approach to overcome the power consumption and delay problems associated with the interconnects by reducing the length of the wires going across the chip. However, 3D integration introduces serious thermal challenges due to the high power density resulting from placing computational units on top of each other. In this work, we first investigate how the existing thermal management, power management and job scheduling policies affect the thermal behavior in 3D chips. We then propose a dynamic thermally-aware job scheduling technique for 3D systems to reduce the thermal problems at very low performance cost. Our approach can also be integrated with power management policies to reduce energy consumption while avoiding the thermal hot spots and large temperature variations.