David Patoulias

Dr. David Patoulias

Department of Chemical Engineering, University of Patras, Patras, Greece

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
ESEvangelia Siouti
Evangelia Siouti
KSKsakousti Skyllakou
Ksakousti Skyllakou
Ioannis KioutsioukisIoannis Kioutsioukis
Ioannis Kioutsioukis
David PatouliasDavid Patoulias
David Patoulias
GFGeorge Fouskas
George Fouskas
SPSpyros Pandis
Spyros Pandis
Air pollution forecasting systems are useful tools for the reduction in human health risks and the eventual improvement of atmospheric quality on regional or urban scales. The SmartAQ (Smart Air Quality) forecasting system combines state-of-the-art meteorological and chemical transport models to provide detailed air pollutant concentration predictions at a resolution of 1 × 1 km2 for the urban area of interest for the next few days. The Weather Research and Forecasting (WRF) mesoscale numerical weather prediction model is used to produce meteorological fields and the PMCAMx (Particulate Matter Comprehensive Air quality Model with extensions) chemical transport model for the simulation of air pollution. SmartAQ operates automatically in real time and provides, in its current configuration, a three-day forecast of the concentration of tens of gas-phase air pollutants (NOx, SO2, CO, O3, volatile organic compounds, etc.), the complete aerosol size/composition distribution, and the source contributions for all primary and secondary pollutants. The system simulates the regional air quality in Europe at medium spatial resolution and can focus, using high resolution, on any urban area of the continent. The city of Patras in Greece is used for the first SmartAQ application, taking advantage of the available Patras’ dense low-cost sensor network for PM2.5 (particles smaller than 2.5 μm) concentration measurements. Advantages of SmartAQ include (a) a high horizontal spatial resolution of 1 × 1 km2 for the simulated urban area; (b) advanced treatment of the organic aerosol volatility and chemistry; (c) use of an updated emission inventory that includes not only the traditional sources (industry, transport, agriculture, etc.), but also biomass burning from domestic heating and cooking; (d) forecasting of not only the pollutant concentrations, but also of the sources contributions for each one of them using the Particulate matter Source Apportionment Technology (PSAT) algorithm.

8 December 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
David PatouliasDavid Patoulias
David Patoulias
EKEvangelos Kallitsis
Evangelos Kallitsis
LPLaura Posner
Laura Posner
SPSpyros Pandis
Spyros Pandis
The changes in the concentration and composition of biomass-burning organic aerosol (OA) downwind of a major wildfire are simulated using the one-dimensional Lagrangian chemical transport model PMCAMx-Trj. A base case scenario is developed based on realistic fire-plume conditions and a series of sensitivity tests are performed to quantify the effects of different conditions and processes. Temperature, oxidant concentration and dilution rate all affect the evolution of biomass burning OA after its emission. The most important process though is the multi-stage oxidation of both the originally emitted organic vapors (volatile and intermediate volatility organic compounds) and those resulting from the evaporation of the OA as it is getting diluted. The emission rates of the intermediate volatility organic compounds (IVOCs) and their chemical fate have a large impact on the formed secondary OA within the plume. The assumption that these IVOCs undergo only functionalization leads to an overestimation of the produced SOA suggesting that fragmentation is also occurring. Assuming a fragmentation probability of 0.2 resulted in predictions that are more consistent with available observations. Dilution leads to OA evaporation and therefore reduction of the OA levels downwind of the fire. However, the evaporated material can return to the particulate phase later on after it gets oxidized and recondenses. The sensitivity of the OA levels and total mass balance on the dilution rate depends on the modeling assumptions. The high variability of OA mass enhancement observed in past field studies downwind of fires may be partially due to the variability of the dilution rates of the plumes.

21 December 2023 in Atmosphere
Verified
Journal Article
Open access
PDF file
ESEvangelia Siouti
Evangelia Siouti
KSKsakousti Skyllakou
Ksakousti Skyllakou
Ioannis KioutsioukisIoannis Kioutsioukis
Ioannis Kioutsioukis
David PatouliasDavid Patoulias
David Patoulias
IAIoannis D. Apostolopoulos
Ioannis D. Apostolopoulos
SPSpyros Pandis
Spyros Pandis
The SmartAQ (Smart Air Quality) forecasting system produces high-resolution (1 × 1 km2) air quality predictions in an urban area for the next three days using advanced chemical transport modeling. In this study, we evaluated the SmartAQ performance for the urban area of Patras, Greece, for four months (July 2021, September 2021, December 2021, and March 2022), covering all seasons. In this work, we assess the system’s ability to forecast PM2.5 levels and the major gas-phase pollutants during periods with different meteorological conditions and local emissions, but also in areas of the city with different characteristics (urban, suburban, and background sites). We take advantage of this SmartAQ application to also quantify the main sources of the pollutants at each site. During the summertime, PM2.5 model performance was excellent (Fbias < 15%, Ferror < 30%) for all sites both in the city center and suburbs. For the city center, the model reproduced well (MB = −0.9 μg m−3, ME = 2.5 μg m−3) the overall measured PM2.5 behavior and the high nighttime peaks due to cooking activity, as well as the transported PM pollution in the suburbs. During the fall, the SmartAQ PM2.5 performance was good (Fbias < 42%, Ferror < 45%) for the city center and the suburban core, while it was average (Fbias < 50%, Ferror < 54%, MB, ME < 3.3 μg m−3) for the suburbs because the model overpredicted the long-range transport of pollution. For wintertime, the system reproduced well (MB = −2 μg m−3, ME = 6.5 μg m−3) the PM2.5 concentration in the high-biomass-burning emission area with an excellent model performance (Fbias = −4%, Ferror = 33%) and reproduced well (MB < 1.1 μg m−3, ME < 3 μg m−3) the background PM2.5 levels. SmartAQ reproduced well the PM2.5 concentrations in the urban and suburban core during the spring (Fbias < 40%, Ferror < 50%, MB < 8.5 μg m−3, ME < 10 μg m−3), while it tended to slightly overestimate the regional pollution. The main local source of fine PM during summer and autumn was cooking, but most of the PM was transported to the city. Residential biomass burning was the dominant particle source of pollution during winter and early spring. For gas-phase pollutants, the system reproduced well the daily nitrogen oxides (NOx) concentrations during the summertime. Predicted NOx concentrations during the winter were consistent with measurements at night but underestimated the observations during the rest of the day. SmartAQ achieved the US EPA modeling goals for hourly O3 concentrations indicating good model performance.