Davin Arifin

Dr. Davin Arifin

University of Nottingham, Nottingham, UK
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2022 in Sensors and Actuators A: Physical
Verified
Journal Article
Open access
DADavin Arifin
Davin Arifin
SMStewart McWilliam
Stewart McWilliam

18 February 2025 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
DADavin Arifin
Davin Arifin
SMStewart McWilliam
Stewart McWilliam

1 December 2024 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
DADavin Arifin
Davin Arifin
SMS. McWilliam
S. McWilliam
The rate sensing performance of ring-based capacitive Coriolis Vibratory Gyroscopes (CVGs) is susceptible to the effects of imperfections and electrostatic nonlinearities. This research investigates the use of the nonlinear electrostatic forces to nullify these effects and replicate linear and trimmed sensor performance at increased vibration amplitudes. The approach used involves applying a suitable voltage distribution to modify the mechanical sensing mode, and a mathematical model is used to demonstrate the implementation of this scheme. For the case of 8 evenly distributed electrodes, a balancing voltage component is introduced to counteract the net forces stemming from the imperfection-induced quadrature coupling and the nonlinear frequency imbalance. The effects of the implementation are demonstrated in terms of improvements to rate sensitivity, bias rate and quadrature error of the device mechanical output. Finite element results are also included to validate the potential of this force balancing scheme. It is shown that the proposed scheme enhances device performance by reducing the bias rate and mechanical quadrature response to negligible levels and increasing rate sensitivity at increased drive amplitudes.

3 April 2025 in Sensors
Verified
Journal Article
Open access
PDF file
DADavin Arifin
Davin Arifin
SMStewart Mcwilliam
Stewart Mcwilliam
This paper investigates the effect of electrostatic nonlinearity on the rate-sensing performance of imperfect ring-based Coriolis Vibrating Gyroscopes (CVGs) for devices having 8 and 16 evenly distributed electrodes. Mathematical models are developed for CVGs operating in (i) an open loop for a linear electrostatically trimmed device, (ii) a closed loop where a sense force balancing is applied to negate the sense quadrature response, and the effects of electrostatic nonlinearity are investigated for increasing drive amplitudes. The modeling indicates the nonlinear responses for 8- and 16-electrode arrangements are quite different, and this can be attributed to the nonlinear frequency imbalance, which depends on the drive and sense frequency softening as well as the presence of self-induced parametric excitation in the sense response. In open loop the 16-electrode arrangement exhibits much weaker levels of nonlinearity than the 8-electrode arrangement because the nonlinear frequency imbalance is less sensitive to drive amplitude. For devices operating in closed-loop with sense force balancing to ensure the drive and sense responses are in-phase/anti-phase, it is shown that ideal rate-sensing performance is achieved at large drive amplitudes for both 8- and 16-electrode arrangements. Using sense force balancing, rate sensing can be achieved using either the sense response or the required balancing voltage. For the latter, large nonlinear frequency imbalances and low damping levels enhance rate-sensing performance.

21 February 2026 in Journal of Sound and Vibration
Verified
Journal Article
Open access
DADavin Arifin
Davin Arifin
SMStewart McWilliam
Stewart McWilliam

1 December 2024 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
DADavin Arifin
Davin Arifin
SMS. McWilliam
S. McWilliam
MEMS capacitively operated ring-based Coriolis vibratory gyroscopes are used to measure angular rate. Under standard operating conditions the ring is driven into resonance and Coriolis coupling generates a response that is proportional to the applied angular rate. In practice capacitive devices are susceptible to electrostatic nonlinearities due to narrow capacitive gaps which potentially degrades the quality of the measurement. One issue is that large amplitude drive responses yield multi-harmonic response which distorts the sense output causing the rate output to vary periodically (i.e. frequency instability). In this research it is shown that this frequency instability can be negated relatively easily by incorporating additional harmonics in the drive force. To implement such an approach it is necessary to use a voltage distribution to generate the appropriate electrostatic forces to eliminate or reduce the multi-frequency mechanical response of the ring. A mathematical model is used to quantify the effects of the implementation of the voltage distribution in terms of discrete Fourier transform of the ring response and the calculated Allan deviation. It is shown that the proposed implementation approximates linear behaviour by reducing the multi-harmonic response by orders of magnitude.