Delia Campanella

Prof. Delia Campanella

Candiolo Cancer Institute, Candiolo, Italy
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2012 in Cancer
Verified
Journal Article
Open access
PDF file
FLFrancesco Leone
Francesco Leone
MGMarco Gatti
Marco Gatti
PMPaolo Massucco
Paolo Massucco
FCFederica Colombi
Federica Colombi
ESElisa Sperti
Elisa Sperti
MAMassimo Aglietta
Massimo Aglietta
BACKGROUND: Chemoradiotherapy (CRT) may render curative resection feasible in patients with locally advanced pancreatic carcinoma (LAPC). The authors previously demonstrated the achievement of significant disease control and a median survival of 14 months by CRT in patients with LAPC. In this study, they evaluated the use of induction chemotherapy followed by a CRT neoadjuvant protocol.METHODS: Patients first received induction gemcitabine and oxaliplatin (GEMOX) (gemcitabine 1000 mg/m2, oxaliplatin 100 mg/m2). Patients without disease progression then received gemcitabine twice weekly (50 mg/m2 daily) concurrent with radiotherapy (50.4 grays) and were re‐evaluated for resectability.RESULTS: Thirty‐nine patients (15 with borderline resectable disease and 24 with unresectable disease) entered the study. The treatment was well tolerated. Disease control was obtained in 29 of 39 patients. Two patients progressed after GEMOX, and 7 progressed after CRT. After a median follow‐up of 13 months, the median progression‐free survival (PFS) was 10.2 months. The median PFS of patients with borderline resectable and unresectable disease was 16.6 and 9.1 months, respectively (P = .056). For the whole group, the median overall survival (OS) was 16.7 months (27.8 months for patients with borderline resectable disease, 13.3 for patients with unresectable disease; P = .045). Eleven patients (9 with borderline resectable disease and 2 with unresectable disease at diagnosis) underwent successful resection. Patients who underwent resection had a significantly longer median PFS compared with nonresected patients (19.7 months vs 7.6 months, respectively). The median OS among resected and nonresected patients was 31.5 months and 12.3 months, respectively (P < .001).CONCLUSIONS: The current results indicated that induction GEMOX followed by CRT is feasible in patients with LAPC. Both those with borderline resectable disease and those with unresectable disease received clinical benefit, a chance to obtain resectability, and improved survival. The authors concluded that this protocol warrants further evaluation. Cancer 2013. © 2012 American Cancer Society.

1 April 2006 in Clinical Radiology
Verified
Journal Article
Closed access
DRDaniele Regge
Daniele Regge
Delia CampanellaDelia Campanella
Delia Campanella
GAG.C. Anselmetti
G.C. Anselmetti
SCS. Cirillo
S. Cirillo
TGT.M. Gallo
T.M. Gallo
MAMassimo Aglietta
Massimo Aglietta

1 January 2013 in Radiology
Verified
Journal Article
Closed access
DRDaniele Regge
Daniele Regge
PMPatrizia Della Monica
Patrizia Della Monica
GGGiovanni Galatola
Giovanni Galatola
CLCristiana Laudi
Cristiana Laudi
ZAZambon Antonella
Zambon Antonella
GGGiovanni Gandini
Giovanni Gandini
To assess the effect of computer-aided detection (CAD) as a second reader on the sensitivity and specificity of computed tomographic (CT) colonography in detecting 6-9-mm colorectal cancer (CRC) lesions. Individuals with clinical indications for colonoscopy--either for symptoms or as part of participating in a surveillance program or CRC screening--were prospectively enrolled at one of 10 academic centers between July 2007 and May 2009. Institutional review board approval was obtained at each clinical site, and all participants provided written informed consent. All participants underwent CT colonography and colonoscopy on the same day. Experienced readers interpreted the CT colonography images unassisted and then reviewed all colorectal lesion-like structures pinpointed by the CAD algorithm. Segmental unblinding of CT colonoscopy findings at colonoscopy was utilized. The sensitivity and specificity of unassisted and CAD-assisted reading in identifying individuals with 6-9-mm lesions were calculated and compared by means of pairwise analysis. A total of 618 participants (mean age, 57.9 years; 54.5% male) were included in the final analysis. Of these participants, 464 (75.1%) had no lesions 6 mm or larger, and 52 (8.4%) had 6-9-mm lesions. The sensitivity of CT colonography with unassisted reading and that with CAD-assisted reading in identifying individuals with 6-9-mm lesions was 65.4% (95% confidence interval [CI]: 50.9%, 78.0%) and 76.9% (95% CI: 63.2%, 87.5%; P = .016), respectively. No significant change in specificity was observed: The specificity of CT colonography with unassisted and that with CAD-assisted reading was 91.8% (95% CI: 88.9%, 94.1%) and 90.9% (95% CI: 88.0%, 93.4%; P = .063), respectively. Evaluation of CAD candidates required an additional 1.6 minutes (25th-75th percentile: 1.0 minute to 3.4 minutes). The addition of CAD to reading performed by experienced readers resulted in a significant benefit in the detection of 6-9-mm polyps at CT colonography in this cohort. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120376/-/DC1.

1 September 2005 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
AFAntonio M. Fea
Antonio M. Fea
FAFederica Annetta
Federica Annetta
SCStefano Cirillo
Stefano Cirillo
Delia CampanellaDelia Campanella
Delia Campanella
MGMassimo De Giuseppe
Massimo De Giuseppe
FGFederico M. Grignolo
Federico M. Grignolo
To evaluate the correlation between white-to-white (WTW) distance as assessed by Orbscan II (Bausch & Lomb) and high-resolution magnetic resonance imaging (MRI) sulcus-sulcus (S-S) measures and to analyze the correlation between age and anterior chamber parameters. Istituto per la Ricerca e la Cura del Cancro, Candiolo, Torino, Italy. Eighty-eight patients had MRI with a 1.5 Tesla imager (GE Medical Systems) using a 3-inch circular coil. T1 weighted fast spin-echo scans were performed on the axial plane. Orbscan II was also used to measure WTW distance, K, anterior chamber depth (ACD), and lens curvature. One eye was randomly selected for analysis. Measures were compared using Spearman correlation, paired Student t test, and analysis of variance (ANOVA; post hoc: Scheffé). Intersession variability was performed in 10 patients. Ten MRI images were randomly selected and measured by 2 operators in a masked fashion (intrasession variability). Intersession and intrasession correlation was good for MRI (r = 0.89 and r = 0.92, respectively), and intersession was good for Orbscan (r = 0.91). When comparing Orbscan II and MRI results, the ACD was well correlated and not significantly different, whereas the S-S and the WTW measures were not correlated and significantly different. Lens thickness and lens diameter were directly correlated with age; S-S, WTW, lens curvature, and ACD were inversely correlated with age. Current methods of measuring the WTW were poorly correlated with anatomical measures. The S-S diameter and other anterior chamber structures significantly change with age, which could give rise to potential problems with posterior chamber phakic intraocular lens sizing position.

1 June 2017 in European Journal of Cancer
Verified
Journal Article
Closed access
LDLorenzo D'Ambrosio
Lorenzo D'Ambrosio
EPErica Palesandro
Erica Palesandro
PBPaola Boccone
Paola Boccone
FTFrancesco Tolomeo
Francesco Tolomeo
SMSara Miano
Sara Miano
GGGiovanni Grignani
Giovanni Grignani

15 June 2018 in European Radiology
Verified
Journal Article
Closed access
PDF file
LVLorenzo Vassallo
Lorenzo Vassallo
ATAlberto Traverso
Alberto Traverso
MAMichelangelo Agnello
Michelangelo Agnello
CBChristian Bracco
Christian Bracco
Delia CampanellaDelia Campanella
Delia Campanella
DRDaniele Regge
Daniele Regge