Diganta Bhusan Das

Prof. Dr. Diganta Bhusan Das

Loughborough University, Loughborough, Leicestershire, UK
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2013 in Journal of Pharmaceutical Sciences
Verified
Journal Article
Open access
PDF file
OOOlolade Olatunji
Ololade Olatunji
Diganta Bhusan DasDiganta Bhusan Das
Diganta Bhusan Das
MGMartin J. Garland
Martin J. Garland
LBLuc Belaid
Luc Belaid
Ryan DonnellyRyan Donnelly
Ryan Donnelly
Insertion behaviour of microneedle (MN) arrays depends upon the mechanical properties of the skin and, MN geometry and distribution in an array. In addressing this issue, this paper studies MN array insertion mechanism into skin and provides a simple quantitative basis to relate the insertion force with distance between two MNs. The presented framework is based on drawing an analogy between a beam on an elastic foundation and mechanism of needle insertion, where insertion force is separated into different components. A theoretical analysis indicates that insertion force decreases as interspacing increases. For a specified skin type, insertion force decreased from 0.029 to 0.028 N/MN when interspacing at MN tip was increased from 50 μm (350 μm at MN base) to 150 μm (450 μm at MN base). However, dependence of insertion force seems to decrease as the interspacing is increased beyond 150 μm. To assess the validity of the proposed model, a series of experiments was carried out to determine the force required for skin insertion of MN. Experiments performed at insertion speed of 0.5 and 1.0 mm/s yielded insertion force values of 0.030 and 0.0216 N, respectively, for 30 μm interspacing at MN base (330 μm interspacing at tip) and 0.028 and 0.0214 N, respectively, for 600 μm interspacing at MN base (900 μm interspacing at tip). Results from theoretical analysis and finite element modelling agree well with experimental results, which show MN interspacing only begins to affect insertion force at low interspacing (<150 μm interspacing at MN base). This model provides a framework for optimising MN devices, and should aid development of suitable application method and determination of force for reliable insertion into skin. © 2013 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 102:1209–1221, 2013

8 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MHMohamed Hemdan
Mohamed Hemdan
Mohamed Ahmed AliMohamed Ahmed Ali
Mohamed Ahmed Ali
Ahmed S. DoghishAhmed S. Doghish
Ahmed S. Doghish
SASherif Sabry abdel-Mageed
Sherif Sabry abdel-Mageed
IEIbrahim M. Elazab
Ibrahim M. Elazab
AAAlaa Amin
Alaa Amin
This comprehensive review delves into the forefront of biosensor technologies and their critical roles in disease biomarker detection and therapeutic drug monitoring. It provides an in-depth analysis of various biosensor types and applications, including enzymatic sensors, immunosensors, and DNA sensors, elucidating their mechanisms and specific healthcare applications. The review highlights recent innovations such as integrating nanotechnology, developing wearable devices, and trends in miniaturisation, showcasing their transformative potential in healthcare. In addition, it addresses significant sensitivity, specificity, reproducibility, and data security challenges, proposing strategic solutions to overcome these obstacles. It is envisaged that it will inform strategic decision-making, drive technological innovation, and enhance global healthcare outcomes by synthesising multidisciplinary insights.

18 February 2021 in Molecules
Verified
Journal Article
Open access
PDF file
Mostafa MabroukMostafa Mabrouk
Mostafa Mabrouk
Diganta Bhusan DasDiganta Bhusan Das
Diganta Bhusan Das
ZSZeinab A. Salem
Zeinab A. Salem
HBHanan H. Beherei
Hanan H. Beherei
Designing of nanomaterials has now become a top-priority research goal with a view to developing specific applications in the biomedical fields. In fact, the recent trends in the literature show that there is a lack of in-depth reviews that specifically highlight the current knowledge based on the design and production of nanomaterials. Considerations of size, shape, surface charge and microstructures are important factors in this regard as they affect the performance of nanoparticles (NPs). These parameters are also found to be dependent on their synthesis methods. The characterisation techniques that have been used for the investigation of these nanomaterials are relatively different in their concepts, sample preparation methods and obtained results. Consequently, this review article aims to carry out an in-depth discussion on the recent trends on nanomaterials for biomedical engineering, with a particular emphasis on the choices of the nanomaterials, preparation methods/instruments and characterisations techniques used for designing of nanomaterials. Key applications of these nanomaterials, such as tissue regeneration, medication delivery and wound healing, are also discussed briefly. Covering this knowledge gap will result in a better understanding of the role of nanomaterial design and subsequent larger-scale applications in terms of both its potential and difficulties.

1 January 2015 in European Journal of Pharmaceutics and Biopharmaceutics
Verified
Journal Article
Open access
THTao Han
Tao Han
Diganta Bhusan DasDiganta Bhusan Das
Diganta Bhusan Das
Transdermal drug delivery (TDD) is limited by the outer layer of the skin, i.e., the stratum corneum. Research on TDD has become very active in the recent years and various technologies have been developed to overcome the resistance of the stratum corneum to molecular diffusion. In particular, researchers have started to consider the possibility of combining the TDD technologies in order to have further increase in drug permeability. Both microneedles (MNs) and ultrasound are promising technologies. They achieve enhancement in drug permeation via different mechanisms and therefore give a good potential for combining with each other. This review will focus on discussing the potential of this combinational technique along with other important issues, e.g., the mechanisms of ultrasound and MNs as it is and these mechanisms which are coupled via the two systems (i.e. MNs and ultrasound). We discuss the possible ways to achieve this combination as well as how this combination would increase the permeability. Some of the undeveloped (weaker) research areas of MNs and sonophoresis are also discussed in order to understand the true potential of combining the two technologies when they are developed further in the future. We propose several hypothetical combinations based on the possible mechanisms involved in MNs and ultrasound. Furthermore, we carry out a cluster analysis by which we determine the significance of this combinational method in comparison with some other selected combinational methods for TDD (e.g., MNs and iontophoresis). Using a time series analysis tool (ARIMA model), the current trend and the future development of combined MNs and ultrasound are also analysed. Overall, the review in this paper indicates that combining MNs and ultrasound is a promising TDD method for the future.

25 February 2015 in Critical Reviews in Environmental Science and Technology
Verified
Journal Article
Open access
LALuqman Abidoye
Luqman Abidoye
KKKamal J. Khudaida
Kamal J. Khudaida
Diganta Bhusan DasDiganta Bhusan Das
Diganta Bhusan Das
In this review, various aspects of geological carbon sequestration are discussed in relation to the principles of two-phase flow in porous media. Literature reports on geological sequestration of CO2 show that the aquifer storage capacity, sealing integrity of the caprock, and the in situ processes, for example, the displacement of brine by supercritical CO2 (scCO2), convection–diffusion–dissolution processes involving scCO2 and brine, geochemical reactions, and mineral precipitation depend on the fluid–fluid–rock characteristics as well as the prevailing subsurface conditions. Considering the complexity of the interrelationships among various processes, experimental investigations and network of mathematical functions are required for the ideal choice of geological site with predictable fluid–fluid–rock behaviors that enhance effective monitoring. From a thorough appraisal of the existing publications, recommendations are made for improvement in the existing simulators to fully couple the entire processes involved in the sequestration operations and in situ mechanisms which include injection rate and pressure, brine displacement, simultaneous flow of free and buoyant phases of CO2, various trapping mechanisms, convection–diffusion–dissolution processes, scCO2–brine–rock reactions, precipitation of the rock minerals, and the consequences on the hydraulic and hydrogeological properties in the course of time as well as the quantity of injected CO2. Suggestion is made for the inclusion of leakage parameters on site-specific basis to quantify the risks posed by the prevailing fluid–fluid–rock characteristics as well as their immediate and future tendencies. Calls are also made for thorough investigations of factors that cause nonuniqueness of the two-phase flow behavior with suggestions for the use of appropriate experimental techniques. The review comprehensively synthesizes the available knowledge in the geological carbon sequestration in a logical sequence.

21 January 2014 in Journal of Diabetes Science and Technology
Verified
Journal Article
Open access
KCKarmen Cheung
Karmen Cheung
THTao Han
Tao Han
Diganta Bhusan DasDiganta Bhusan Das
Diganta Bhusan Das
Background: Many experiments conducted in the literature have investigated the effect of microneedles (MNs) on insulin permeation across skin. There are also a number of articles that deal with the effect of MN insertion force in skin. However, there is little known on quantifying the relationship between the effect of MN insertion force and the amount of insulin permeated for given MNs. This issue is addressed in this article. Methods: MNs of 1100 µm and 1400 µm are used to conduct in vitro permeability experiments on porcine skin, using insulin. Histological images of MN treated skin are obtained from a microtome and the viscoelastic properties of the skin sample are measured using a rheometer. An in-house insertion force device is utilized that can reproducibly apply a specified force on MNs for a set period of time using compressed air. Results: It is deduced that when porcine skin was pretreated with an applied force of 60.5 N and 69.1 N, the resultant amount of insulin permeated was approximately 3 µg and 25 µg over a 4-hour period for the MNs used. Conclusions: The amount of MN force applied to porcine skin was shown to be related to the amount of insulin permeated. An increase in insertion force increase the amount of insulin permeated. It was also demonstrated that using insufficient force may have reduced or prevented the amount of insulin passing through the skin, regardless of the geometry of the MNs.