Dinesh Singh Bhandari

Dr. Dinesh Singh Bhandari

School of engineering, University of Glasgow, Glasgow, Glasgow City, UK
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2022 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
DBDinesh Singh Bhandari
Dinesh Singh Bhandari
DTDharmendra Tripathi
Dharmendra Tripathi
OBO. Anwar Bég
O. Anwar Bég
Theoretical studies of micro-electro-mechanical systems provide important insight into the mechanisms and optimization of such devices for a range of applications, including biomedical and chemical engineering. Inspired by emerging applications of microfluidics, unsteady viscous flow in a microchannel with periodic membrane pumping modulated by electro-magnetohydrodynamics is analyzed in a mathematical framework. The membrane kinematics induces the pressure inside the microchannel, where an electric field enhances the capability of the pumping flow rate. This model is formulated based on the Navier–Stokes equations, the Poisson equation, and the Maxwell electromagnetic equations and is further simplified using the lubrication approximations and Debye–Hückel linearization. The transformed dimensionless conservation equations under appropriate boundary conditions are analytically solved and the graphical results are illustrated through MATLAB (2019b) software. From the computational results, it is found that the Hartmann number enhances the fluid pressure uniformly throughout the microchannel, while the electric field parameter enforces the direction of the pressure-driven flow. The time-averaged flow rate exhibits a linear decay with axial pressure gradient, and it is strongly elevated with electric field parameter whereas it is weakly increased with electric double layer thickness parameter. It is further observed that the fluid is driven unidirectionally by the membrane contractions via a particle tracking simulation method. This study is relevant to provide the parametric estimation in designing the magnetic field-based microfluidics devices for microlevel transport phenomena.

3 October 2022 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
VNV. K. Narla
V. K. Narla
DTDharmendra Tripathi
Dharmendra Tripathi
DBDinesh Singh Bhandari
Dinesh Singh Bhandari
OBO. Anwar Beg
O. Anwar Beg

1 June 2022 in Physics of Fluids
Verified
Journal Article
Open access
DTDharmendra Tripathi
Dharmendra Tripathi
DBDinesh Singh Bhandari
Dinesh Singh Bhandari
OBO. Anwar Bég
O. Anwar Bég
SARS-CoV-2 is a novel viral species that has been identified as a highly infectious disease. Scientists have endeavored to collect essential information to better characterize the behavior of this virus, including droplet transmission and airborne effects. However, it is not clear, thus far, whether temperature can substantially alter the pandemic trajectory. This present study, therefore, aims to investigate how temperature may affect virus transmission in peristaltic blood vessels and, furthermore, how virus density and particle diameter will affect the transmission of the virus from an infected person to a non-infected person. The modeling deployed assumes that coronavirus particles with a diameter of 120 μm and a density of 1 g/cm3 move in the direction of blood flow. The quantity of SARS-CoV-2 virions (entire virus particles) inside a microdroplet is calculated by considering the Kepler conjecture method, and the transmission percentage of the viral load is also computed. It is observed that the microdroplet carries a smaller amount of coronavirus particles, so an airborne (DP<2 μm) infection is less harmful. Furthermore, computational simulations using the proposed model reveal some interesting insight into how rapidly the SARS-CoV-2 virus propagates in the circulatory system, and estimate the infection in blood and tissues. From these results, it is found that the small virion (dp<100 nm) rapidly settles inside the bloodstream and infects tissues; however, the duration of infection is short due to the low viscosity of the blood. Furthermore, the closed packed structure of the virions is loosened in the blood vessel due to the temperature of the blood.

25 December 2022 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
DBDinesh Singh Bhandari
Dinesh Singh Bhandari
DTDharmendra Tripathi
Dharmendra Tripathi

1 December 2023 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
DRDaya Ram
Daya Ram
DBDinesh Singh Bhandari
Dinesh Singh Bhandari
DTDharmendra Tripathi
Dharmendra Tripathi
KSKushal Sharma
Kushal Sharma
Kidney stones and Escherichia coli bacterial particles are mineral aggregates found inside the kidney and bladder that cause urinary tract infections and complications during urination. Therefore, it is essential to understand that how such stones create the obstruction in the urine flow and what are the possible solutions to remove them from the urinary system? In view of the complications in the urinary system due to bacteria and CaOx, the major objectives of this study are to investigate (a) how electro-osmosis modulates the urine flow and helps in the removal of CaOx particles and bacteria via urine flow and (b) how diameter and density of the particles will affect the motion of the particles via urine flow? An electrolyte solution with Newtonian model for the urine and a moving wavy channel with time and axial displacement for urinary track are considered. Basset–Boussinesq–Oseen equation is employed to analyze the motion of CaOx and bacteria. Poisson–Boltzmann equation is considered to examine the distribution of the electric potential in urine. Analytical solutions are derived under the suitable assumptions and suitable boundary conditions for the present biophysical model. The results showed that (a) backward motion of bacterial particles was observed via urine flow and (b) the large size of CaOx particle covers fewer trajectories with slower velocity through urine flow, which may be the reasons of obstructions/infections in the urine flow. It is further concluded that the axial electric field increases the trajectory and velocity of the CaOx particle and bacterial particles, which will help in proper functioning of the urine flow and in the removal of such particles.

22 February 2024 in Chinese Journal of Physics
Verified
Journal Article
Closed access
DBDinesh Singh Bhandari
Dinesh Singh Bhandari
ABAnjali Bhardwaj
Anjali Bhardwaj
DTDharmendra Tripathi
Dharmendra Tripathi