Eckehart Schöll

Dr. Eckehart Schöll

orcid
Department of Emergency Medicine, Bethesda Spital, Basel, CH

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 1998 in Spine
Verified
Journal Article
Closed access
PHPaul Heini
Paul Heini
Eckehart SchöllEckehart Schöll
Eckehart Schöll
DWDaniel Wyler
Daniel Wyler
SEStefan Eggli
Stefan Eggli
Case report of a fatal complication of pedicle screw instrumentation and review of the literature. To describe the clinical and postmortem findings in a 35-year-old man who sustained a T11 burst fracture that was managed by transpedicular posterior instrumentation and who died 12 days after surgery of cardiac tamponade caused by a prick injury of the right coronary artery. Posterior pedicle screw instrumentation is considered a safe and effective method for stabilizing a spinal motion segment. Nevertheless, there are several rare but significant complications that may occur. This is the first report of a heart tamponade after transpedicular screw insertion. A 35-year-old man was treated for a T11 burst fracture with posterior transpedicular stabilization. The surgery was uncomplicated. Twelve days after the intervention, the patient died of cardiogenic shock. Postmortem examination showed a heart tamponade of 350 mL blood originating in a prick injury of the right coronary artery. Histologic findings showed evidence that the injury was caused during surgery by a Kirschner wire. There are numerous possible intraoperative complications in posterior pedicle screw fixation, such as nerve root and spinal cord injuries. This case of a fatal heart tamponade after transpedicular screw insertion is rare. It shows that the surgeon must be aware of potential risks associated with such a procedure and have a comprehensive three-dimensional understanding of the anatomic structures involved.

1 August 2000 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
Eckehart SchöllEckehart Schöll
Eckehart Schöll
SEStefan Eggli
Stefan Eggli
RGReinhold Ganz
Reinhold Ganz

20 November 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Eckehart SchöllEckehart Schöll
Eckehart Schöll
MGMark Ulrich Gerbershagen
Mark Ulrich Gerbershagen
WVWerner Vach
Werner Vach
MRMaria Rösli
Maria Rösli
RLRainer Litz
Rainer Litz
Background/Objectives: This pragmatic randomized controlled trial evaluated the efficacy of ultrasound-guided supraclavicular nerve (SCLN) block compared to standard pain management in patients with acute displaced clavicle fractures (CFs) in an emergency department (ED) setting. Secondary outcomes included time to first request for analgesics, opioid consumption, and patient satisfaction. Methods: Forty-one patients with acute displaced CFs were randomized to receive either an SCLN block (n = 19) or routine pain management (n = 22). Pain intensity was recorded at admission and at 1, 2, 4, 6, 12, and 24 h. Patient satisfaction was assessed after 24 h. Analgesic use, adverse reactions, and adverse events were documented for 24 h. Results: Pain intensity, measured by the numeric rating scale (NRS), was significantly lower in the SCLN group at all time points within the first 12 h (p < 0.001). After one hour, 68% of patients in the SCLN group reported an NRS of 0–2, compared to 19% in the control group. The time to first request for analgesics was markedly longer in the SCLN group (9.1 h vs. 0.7 h). In two patients, SCLN visualization was insufficient, and a cervical plexus block was performed instead. Four patients in the SCLN block group reported adverse reactions. Patient satisfaction after 24 h was significantly higher in the SCLN group (p < 0.001), with 85% indicating they would choose the block again. Conclusions: Ultrasound-guided selective SCLN block appears to be an effective and well-tolerated method for acute analgesia in patients with displaced CFs, with the most pronounced benefit observed during the first 12 h. Patient acceptance of the procedure was high.

18 October 2024 in Ultraschall in der Medizin - European Journal of Ultrasound
Verified
Journal Article
Open access
PDF file
Eckehart SchöllEckehart Schöll
Eckehart Schöll
MJMarcel Jakob
Marcel Jakob
WVWerner Vach
Werner Vach
Ultrasonography is increasingly being discussed as an alternative to X-rays in emergency department settings. Systematic comparisons of the 2 modalities are often based on the use of computed tomography as a reference. When diagnosing patients with elbow trauma, the physicians at our emergency department experienced that ultrasonography can be more informative than cone beam computed tomography for identifying radial head fractures. Our goal is to share this experience with the scientific community. All patients diagnosed with a radial head fracture in our emergency department between January 2021 and November 2022 were identified. The images of 18 cases in which both point-of-care ultrasonography and cone beam computed tomography had been used were reviewed by us. Eight examples were selected illustrating the variation in coincidence or discrepancy between ultrasonography and computed tomography. The 8 examples illustrate that ultrasonography can be more informative than cone beam computed tomography or vice versa. The joint application of ultrasonography and computed tomography is advisable if a correct diagnosis of the extent and components of radial head fractures is of uttermost importance.

1 December 2021 in Notfall + Rettungsmedizin
Verified
Journal Article
Closed access
PDF file
Eckehart SchöllEckehart Schöll
Eckehart Schöll
MRM. Rösli
M. Rösli

16 August 2021 in Sports Orthopaedics and Traumatology
Verified
Journal Article
Closed access
Eckehart SchöllEckehart Schöll
Eckehart Schöll
MKMarkus Knupp
Markus Knupp