Edoardo Sotgiu

Mr. Edoardo Sotgiu

International Iberian Nanotechnology Laboratory, Braga, Portugal
+1
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2016 in Meccanica
Verified
Journal Article
Closed access
PDF file
MSMine Sarac
Mine Sarac
MSMassimiliano Solazzi
Massimiliano Solazzi
Edoardo SotgiuEdoardo Sotgiu
Edoardo Sotgiu
MBMassimo Bergamasco
Massimo Bergamasco
Antonio FrisoliAntonio Frisoli
Antonio Frisoli

1 August 2015
Verified
Conference Paper
Closed access
MBM. Barsotti
M. Barsotti
DLD. Leonardis
D. Leonardis
Claudio LoconsoleClaudio Loconsole
Claudio Loconsole
MSM. Solazzi
M. Solazzi
Edoardo SotgiuEdoardo Sotgiu
Edoardo Sotgiu
AFA. Frisoli
A. Frisoli
In this paper we propose a full upper limb exoskeleton for motor rehabilitation of reaching, grasping and releasing in post-stroke patients. The presented system takes into account the hand pre-shaping for object affordability and it is driven by patient's intentional control through a self-paced asynchronous Motor Imagery based Brain Computer Interface (MI-BCI). The developed antropomorphic eight DoFs exoskeleton (two DoFs for the hand, two for the wrist and four for the arm) allows full support of the manipulation activity at the level of single upper limb joint. In this study, we show the feasibility of the proposed system through experimental rehabilitation sessions conducted with three chronic post-stroke patients. Results show the potential of the proposed system for being introduced in a rehabilitation protocol.

3 July 2020 in Journal of Microelectromechanical Systems
Verified
Journal Article
Open access
Edoardo SotgiuEdoardo Sotgiu
Edoardo Sotgiu
DADiogo Aguiam
Diogo Aguiam
Carlos CalazaCarlos Calaza
Carlos Calaza
JRJose Rodrigues
Jose Rodrigues
JFJose Fernandes
Jose Fernandes
JGJoao Gaspar
Joao Gaspar
This work presents a flexible polyimide-based capacitive tactile sensing array with sub-millimeter spatial resolution. The sensor is conceived to be embedded in a multimodal artificial finger to detect and classify the texture morphology of an object's surface. The proposed tactile sensor comprises a 16x 16 array of capacitive sensing units. Each unit is composed of a parallel square electrode pairs (340 μm x 340 μm) separated by a compressible air cavity and embedded into a flexible polyimide substrate. Standard MEMS microfabrication techniques were used to develop the sensor. The polyimide device was covered with a thin compressible PDMS layer to tune the normal pressure sensitivity and dynamic range (225-430 μm thin PDMS layer resulting in 0.23-0.14 fF/kPa). The detection of the surface morphologies of a regular grating stamp for different orientation and a small metallic nut placed on the sensor is demonstrated, showing a 420 μm spatial resolution. The proposed sensor represents a novel capacitive tactile sensing device with a sub-mm resolution of human fingertip sensitivity. [2020-0188]

1 August 2018 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
MPMiguel Ángel Padilla-Castañeda
Miguel Ángel Padilla-Castañeda
Edoardo SotgiuEdoardo Sotgiu
Edoardo Sotgiu
MBMichele Barsotti
Michele Barsotti
Antonio FrisoliAntonio Frisoli
Antonio Frisoli
POPiero Orsini
Piero Orsini
MBMassimo Bergamasco
Massimo Bergamasco
The use of robotic rehabilitation in orthopaedics has been briefly explored. Despite its possible advantages, the use of computer-assisted physiotherapy of patients with musculoskeletal injuries has received little attention. In this paper, we detailed the development and evaluation of a robotic-assisted rehabilitation system as a new methodology of assisted physiotherapy in orthopaedics. The proposal consists of an enhanced end-effector haptic interface mounted in a passive mechanism for allowing patients to perform upper-limb exercising and integrates virtual reality games conceived explicitly for assisting the treatment of the forearm after injuries at the wrist or elbow joints. The present methodology represents a new approach to assisted physiotherapy for strength and motion recovery of wrist pronation/supination and elbow flexion-extension movements. We design specific game scenarios enriched by proprioceptive and haptic force feedback in three training modes: passive, active, and assisted exercising. The system allows the therapist to tailor the difficulty level on the observed motion capacity of the patients and the kinesiology measurements provided by the system itself. We evaluated the system through the analysis of the muscular activity of two healthy subjects, showing that the system can assign significant working loads during typical physiotherapy treatment profiles. Subsequently, a group of ten patients undergoing manual orthopaedic rehabilitation of the forearm tested the system, under similar conditions at variable intensities. Patients tolerated changes in difficulty through the tests, and they expressed a favourable opinion of the system through the administered questionnaires, which indicates that the system was well accepted and that the proposed methodology was feasible for the case study for subsequently controlled trials. Finally, a predictive model of the performance score in the form of a linear combination of kinesiology observations was implemented in function of difficult training parameters, as a way of systematically individualising the training during the therapy, for subsequent studies.

1 March 2004 in Sensor Review
Verified
Journal Article
Closed access
PDF file
AFA. Frisoli
A. Frisoli
Edoardo SotgiuEdoardo Sotgiu
Edoardo Sotgiu
Carlo Alberto AvizzanoCarlo Alberto Avizzano
Carlo Alberto Avizzano
DCD. Checcacci
D. Checcacci
MBM. Bergamasco
M. Bergamasco
This paper analyzes the design of a force‐based impedance control for a haptic interface system characterized by a parallel kinematics. By exploiting the features of parallel mechanisms, which perform better than the serial ones in terms of dynamic performance, stiffness and position accuracy, and by implementing a closed‐loop force control, the transparency of a haptic master system and the fidelity of resultant force feedback can be consistently improved. Issues for design and control as well as aspects of performance evaluation of haptic interfaces are treated within the paper and some results of the experimental characterization of a haptic interface are presented.

1 June 2015
Verified
Conference Paper
Closed access
Domenico BuongiornoDomenico Buongiorno
Domenico Buongiorno
MBMichele Barsotti
Michele Barsotti
Edoardo SotgiuEdoardo Sotgiu
Edoardo Sotgiu
Claudio LoconsoleClaudio Loconsole
Claudio Loconsole
MSMassimiliano Solazzi
Massimiliano Solazzi
AFAntonio Frisoli
Antonio Frisoli
This paper presents a myoelectric control of an arm exoskeleton designed for rehabilitation. A four-muscles-based NeuroMusculoSkeletal (NMS) model was implemented and optimized using genetic algorithms to adapt the model to different subjects. The NMS model is able to predict the shoulder and elbow torques which are used by the control algorithm to ensure a minimal force of interaction. The accuracy of the method is assessed through validation experiments conducted with two healthy subjects performing free movements along the pseudo-sagittal plane. The experiments show promising results for our approach showing its potential for being introduced in a rehabilitation protocol.