Corrosion of steel bars is a major issue for the management of existing reinforced concrete structures, since affecting many ageing structures and infrastructures and introducing risk for safety and reliability, as well as high maintenance costs. Intervention strategies should be planned and carried out according to the effective state of deterioration and to the expected evolution of performances over time. The critical parameters needed to evaluate these performances are the intensity and pattern of the corrosion attack, referring to both extension and depth of the attack. However, this information is rarely available and hard to predict when dealing with real structures. This paper presents a field investigation on existing corroded structures characterized by different environmental conditions. Corroded bars were removed from structural elements, the corrosion patterns were studied, and then the bars were tested to determine their mechanical properties. The objective of this study is to increase the knowledge of the effects of corrosion in natural environments and to propose a method to relate easy-measurable environmental conditions with the characteristics of the expected corrosion attack, which need to be further validated.
The seismic retrofit of the existing building heritage represents an urgent issue to be faced and innovative solutions which allow to overcome renovation barriers are needed. In this scenario, pin-supported (PS) walls represent an eligible solution, enabling linearization of the deformation of the frame along its height and inhibiting soft storey collapse mechanisms. The PS wall can be connected to the existing building from outside, thereby avoiding disruption to occupants or their relocation, which are acknowledged as the main barriers to the renovation nowadays. Suitability of PS wall solutions in the seismic retrofit of the existing building stock has been investigated herein, particularly in the case of existing reinforced concrete (RC) buildings, preliminarily focusing on 2D RC frames. The paper shows the weaknesses and strengths of the PS wall solution in relation to the specific features of the considered buildings. An analytical closed-form formulation is proposed and applied as a preliminary tool to evaluate the load distribution in the existing frame and in the PS wall after the retrofit considering the first mode of vibration of the retrofitted system. The results show that, in some conditions, the application of PS walls may be detrimental to the structural response. Along with the evaluation of the effectiveness of the retrofit solution, the proposed formulation allows a preliminary design of the retrofit system. Finally, a series of finite element model analyses have been carried out for validation purposes showing a good agreement between the proposed analytical formulation and the numerical results.
The effects of deterioration strongly impact the expected future service life and the structural performances of existing reinforced concrete structures. Currently, straightforward methodologies are required to include such effects in the assessment and renovation of the RC buildings’ heritage. A simplified protocol enabling the detection, evaluation, and modelling of corrosion effects is presented in this paper. The protocol provides the guidance for the design and management of the on-site diagnostic campaign, aimed at identifying a possible corrosion risk scenario. Then, equivalent damage parameters describing corrosion effects in the structural models can be calibrated. Structural performances over time can be assessed to predict the structural residual life, maintenance management criteria and timing, and major indications on the feasibility of the retrofit intervention, or the unavoidable need of demolition. The application of the proposed protocol to some case studies emphasises the effectiveness of the procedure for detecting possible activated corrosion processes and for supporting engineers in their decision-making process and choice of renovation strategy.
8 February 2023 in Bulletin of Earthquake Engineering
Pin-supported (PS) walls represent a possible solution for the seismic retrofit of existing reinforced concrete (RC) buildings, enabling linearization of the frame deformation along its height and consequently inhibiting soft storey collapse mechanisms. The effectiveness of this rehabilitation technology is strongly related to the characteristics of the existing frames, especially to the vertical distribution of the frame storey lateral stiffness. Since a larger 1st storey lateral stiffness may lead to a detrimental structural response of the retrofitted system, an alternative solution obtained from removing the connecting link between the 1st floor of the existing building and the pin-supported wall is investigated in this paper. An analytical method is proposed to derive the distribution of the internal actions in a dual 2D RC frame-PS wall system without the link at the 1st floor level, considering both a linear and nonlinear behaviour of the frame. It emerges that some parameters describing the structure type can provide straightforward information on the suitability of this solution in the seismic retrofit of existing RC buildings. As a result, a simplified procedure has been derived to preliminarily define the retrofit system configuration and evaluate the maximum demand in the PS wall. Such a procedure is finally applied with reference to a frame representing a RC building and finite element model analyses are carried out for validation purposes.
1 June 2019 in IOP Conference Series: Earth and Environmental Science
When is demolition mandatory? To date there is a lack of specific tools and protocols enabling a rigorous scientific assessment of the deterioration level of existing structures, guiding the choice between the real possibility of renovation or the unavoidable need of demolition. In the present paper, an attempt is made to develop a protocol suitable to assess the actual capacity of existing structures and predict their future behaviour based on inspection and diagnosis of the building. The potential benefit of such a tool is to help detecting the best intervention strategy making the renovation process more sustainable and efficient. Toward this perspective, a critical analysis and comparison of literature models on the residual capacity of structural elements has already been carried out by the authors. The assessment of the preservation state is herein further extended to the overall structural level, by proposing a new approach relating the performance of deteriorated elements over time to the behaviour of the whole structural system.