The transition toward high shares of non-programmable renewable energy sources in the power grid requires an increase in the grid flexibility to guarantee grid reliability and stability. This work, developed within the EU project Grasshopper, identifies hydrogen Fuel Cell (FC) power plants, based on low temperature PEM cells, as a source of flexibility for the power grid. A dynamic numerical model of the flexible FC system is developed and tested against experimental data from a 100-kW pilot plant, built within the Grasshopper project. The model is then applied to assess the flexible performance of a 1 MW system in order to optimize the scale-up of the pilot plant to the MW-size. Simulations of load-following operation show the flexibility of the plant, which can ramp up and down with a ramp rate depending only on an externally imposed limit. Warm-up simulations allow proposing solutions to limit the warm-up time. Of main importance are the minimization of the water inventory in the system and the construction of a compact system, which minimizes the distance between the components.
11 November 2024 in IET Renewable Power Generation
The EU project PROMETEO has the scope of testing a 25 kW solid oxide electrolysis system integrated with a concentrated solar power plant via thermal energy storage in a relevant environment. Given the plant layout and the hydrogen demand characteristics, this work aims to identify how to operate the system effectively when renewable electricity is unavailable and how to modulate the load during hydrogen generation, thus defining the system's operation modes and control strategy. A 5 kW e stack has been tested at the FBK facility. The hot standby tests show that feeding a reducing gas at the negative electrode and air at the positive electrode, without polarizing the stack, effectively keeps the stack hot at 750°C and prevents degradation. Conversely, the electric protection approach leads to significant stack degradation (15% voltage drop in 200 h for one cluster). Regarding modulation of hydrogen generation, with low steam flowrates, the stack current and the flow rate of produced hydrogen mainly depend on the steam flow rate, while it is not affected by the stack temperature; conversely, with high steam flowrates, the current depends only on the stack temperature (from 25 A at 670°C to 65 A at 760°C). Based on the results, two hot standby modes and two load control strategies to be implemented and tested in the PROMETEO prototype are proposed.