Eligiusz Pawłowski

Dr. Eligiusz Pawłowski

Department of Automation and Metrology, Lublin University of Technology, Lublin, Lubelskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Przemysław OtomańskiPrzemysław Otomański
Przemysław Otomański
Eligiusz PawłowskiEligiusz Pawłowski
Eligiusz Pawłowski
Anna SzlachtaAnna Szlachta
Anna Szlachta
This paper discusses the issue of the self-heating effect of resistance sensors during temperature measurement. The self-heating effect causes temperature measurement errors. The aim of this work was to develop a method for in situ assessment of the thermal resistance between a self-heating thermometer and its surrounding environment, the temperature of which is measured. The proposed method is used to assess the uncertainty resulting from the heat transfer from the thermometer to the surrounding environment, which allows increased measurement accuracy. The proposed method consists of experimental determination of the sensor’s temperature characteristics in relation to the heating power for different values of the measuring current. Sample measurements were carried out on a representative group of resistance temperature sensors. The relationship of the internal thermal resistance to the type of sensor design and the relationship of the external resistance to the ambient conditions were demonstrated. The developed method allows the appropriate measuring current of the resistance temperature sensor to be selected according to its design, the mounting method, and the environmental conditions, which ensures that measurement errors are maintained at an appropriately low level.

3 March 2017 in Measurement Science and Technology
Verified
Journal Article
Closed access
Eligiusz PawłowskiEligiusz Pawłowski
Eligiusz Pawłowski
A novel thermal flow sensor with a frequency output is presented. The sensor provides a pulse-train output whose frequency is related to the fluid flow rate around a self-heating thermistor. The integrating properties of the temperature sensor have been used, which allowed for realization of the pulse frequency modulator with a thermal feedback loop, stabilizing the temperature of the sensor placed in the flowing medium. The system assures a balance of the amount of heat supplied in the impulses to the sensor and the heat given up by the sensor in a continuous way to the flowing medium. Therefore the frequency of output pulse-train is proportional to the medium flow velocity around the sensor. The special feature of the presented solution is the total integration of the thermal sensor with the measurement signal conditioning system. i.e. the sensor and conditioning system are not separate elements of the measurement circuit, but constitute a whole in the form of a thermal heat-balance mode flow-to-frequency converter. The frequency signal from the converter may be directly connected to the microprocessor digital input, which with use of the standard built-in counters may convert the frequency into a numerical value of high precision. The sensor has been experimentally characterized as a function of the average flow velocity of air at room temperature.

17 September 2021 in Measurement Science Review
Verified
Journal Article
Open access
PDF file
Przemysław OtomańskiPrzemysław Otomański
Przemysław Otomański
Eligiusz PawłowskiEligiusz Pawłowski
Eligiusz Pawłowski
Anna SzlachtaAnna Szlachta
Anna Szlachta
The paper presents a possible application of integrated LabVIEW environment to the final evaluation of measurement results in direct measurement. The possibilities of presenting and visualizing the uncertainty of measurement results in a convenient and user-friendly form are also discussed. The topics discussed in the paper were presented using a developed application in LabVIEW. The paper discusses the topic of measurement of direct voltages in the presence of strong electromagnetic interferences. These problems are frequently omitted or hardly emphasized. It presents a suitable measuring system, a virtual measuring instrument created in the LabVIEW environment, and the results of tests carried out for an example NI PCI-6221 data acquisition board. The described approach can be applied also in other measurement situations.

1 August 2015
Verified
Conference Paper
Closed access
Eligiusz PawłowskiEligiusz Pawłowski
Eligiusz Pawłowski
The sensor with frequency output converts the measured quantity to the pulse signal, the instantaneous frequency of which is proportional to the instantaneous values of the input signal. Measurement of the pulse signal frequency is always a measurement of a mean value and direct measuring of its instantaneous value is not possible. The paper contains the analysis of the principles of operation of the frequency output sensor and an appropriate generalized flow chart. A processing algorithm allowing to reconstruct the input signal on the basis of digitally measured time intervals between the subsequent impulses of the output signal is presented. The suggested approach is presented using the example of an incremental rotary encoder and a Voltage-to-Frequency Converter.

18 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
Eligiusz PawłowskiEligiusz Pawłowski
Eligiusz Pawłowski
Anna SzlachtaAnna Szlachta
Anna Szlachta
Przemysław OtomańskiPrzemysław Otomański
Przemysław Otomański
For newly developed measuring systems, it is easy to estimate type-B uncertainties based on technical data from the measuring modules applied. However, it is difficult to estimate A-type uncertainties due to the unknown type and level of interferences infiltrating the measuring system. This is a particularly important problem for measurements carried out in the presence of typical of power grid disturbances. The aim of the research was to develop a method and a measurement stand for experimental assessment of uncertainties in a measuring system that makes use of data acquisition modules containing analog-to-digital converters (ADCs). The paper describes, in detail, the design of a completed test stand. It presents an original application in the LabVIEW environment, which enables testing the dependence of the uncertainties with the quantity of the measurements averaged in a series, for different kinds and levels of interferences infiltrating the measuring path. The results of tests for several popular measuring modules are presented. An analysis of the determined uncertainties was carried out in relation to the parameters of the tested measurement modules and for various levels of interferences. It is proved that an increase in the number of averaged measurements to approx. 100–200 always results in a decrease in uncertainty for each tested module and under all conditions. However, a further increase in the quantity of measurements, even up to 1000 averaged measurements, proved reasonable only for high-accuracy modules, in particular with a high level of interferences. An excessive increase in the quantity of averaged measurements proved a low effect for modules characterised by a low resolution and with a low level of interferences. The measurement results also proved that when estimated, uncertainties in the interference probability distribution are significant, especially if they deviate from normal distribution.

5 July 2018 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
Eligiusz PawłowskiEligiusz Pawłowski
Eligiusz Pawłowski
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.