Eran Leshem

Prof. Eran Leshem

orcid
Cardiac electrophysiologist, researcher and director of acad...

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in JACC: Clinical Electrophysiology
Verified
Journal Article
Closed access
Eran LeshemEran Leshem
Eran Leshem
IZIsrael Zilberman
Israel Zilberman
CTCory M. Tschabrunn
Cory M. Tschabrunn
MBMichael Barkagan
Michael Barkagan
FCFernando M. Contreras-Valdes
Fernando M. Contreras-Valdes
EAElad Anter
Elad Anter

30 May 2018 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
MBMichael Barkagan
Michael Barkagan
FCFernando M. Contreras‐Valdes
Fernando M. Contreras‐Valdes
Eran LeshemEran Leshem
Eran Leshem
ABAlfred E. Buxton
Alfred E. Buxton
HNHiroshi Nakagawa
Hiroshi Nakagawa
EAElad Anter
Elad Anter

1 August 2020 in JACC: Clinical Electrophysiology
Verified
Journal Article
Closed access
HYHagai D. Yavin
Hagai D. Yavin
Eran LeshemEran Leshem
Eran Leshem
ASAyelet Shapira-Daniels
Ayelet Shapira-Daniels
JSJakub Sroubek
Jakub Sroubek
MBMichael Barkagan
Michael Barkagan
EAElad Anter
Elad Anter

1 August 2018 in JACC: Clinical Electrophysiology
Verified
Journal Article
Closed access
EAElad Anter
Elad Anter
AKAndre G. Kleber
Andre G. Kleber
MRMarkus Rottmann
Markus Rottmann
Eran LeshemEran Leshem
Eran Leshem
MBMichael Barkagan
Michael Barkagan
ABAlfred E. Buxton
Alfred E. Buxton

1 October 2018 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
MBMichael Barkagan
Michael Barkagan
MRMarkus Rottmann
Markus Rottmann
Eran LeshemEran Leshem
Eran Leshem
CSChangyu Shen
Changyu Shen
ABAlfred E. Buxton
Alfred E. Buxton
EAElad Anter
Elad Anter
Background: Radiofrequency ablation using irrigated catheters is performed using a power-controlled mode. However, lesion size is dependent on current delivery at a particular impedance, such that a power value alone may not reflect actual energy delivery, resulting in lesion size variability at similar power settings. We hypothesized that modulating baseline impedance at fixed power settings affects ablation lesion dimensions. Methods: In 20 ex vivo swine hearts, radiofrequency ablation was performed using an irrigated catheter at a fixed power setting of 30 W per 20 seconds and a multistepped impedance load (100–210Ω). In 4 in vivo thigh muscle preparations and right atria, ablation was performed using similar power settings at 3 baseline impedances: low (90–130Ω), intermediate (131–180Ω), and high (181–224Ω). The relationship between baseline impedance, current, and lesion dimensions was examined. Results: Baseline impedance had a strong negative correlation with current squared ( I 2 ) for all experimental models: ex vivo (R=−0.94; P <0.0001), thigh muscle (R=−0.93; P <0.0001), and right atria (R=−0.94; P <0.0001). Lesion dimensions at similar power settings were highly variable and directly related to I 2 (width [R=0.853], depth [R=0.814]). In the thigh muscle, lesion depth was 8.2±0.7, 6.5±0.8, and 4.2±0.5 mm for low, intermediate, and high impedance, respectively ( P <0.0001). In right atria lines, low baseline impedance resulted in wider lines (7.2±1.4 mm) relative to intermediate (5.8±1.8 mm) and high impedance (4.7±1.7 mm; P <0.0001). Conclusions: Radiofrequency ablation in a power control mode results in variable lesion dimensions that are partially related to differences in baseline impedance and current output. Ablation at a lower baseline impedance results in increased current output and lesion dimensions.

1 August 2019 in JACC: Clinical Electrophysiology
Verified
Journal Article
Closed access
MBMichael Barkagan
Michael Barkagan
Eran LeshemEran Leshem
Eran Leshem
ASAyelet Shapira-Daniels
Ayelet Shapira-Daniels
JSJakub Sroubek
Jakub Sroubek
ABAlfred E. Buxton
Alfred E. Buxton
EAElad Anter
Elad Anter