Eva Burdová

Mrs. Eva Burdová

Technical University of Košice, Faculty of Civil Engineering
+1
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2017 in Building and Environment
Verified
Journal Article
Closed access
Silvia VilcekovaSilvia Vilcekova
Silvia Vilcekova
LMLudmila Meciarova
Ludmila Meciarova
Eva BurdováEva Burdová
Eva Burdová
JKJana Katunska
Jana Katunska
DKDanica Kosicanova
Danica Kosicanova
SDSaeed Doroudiani
Saeed Doroudiani

Silvia VilcekovaSilvia Vilcekova
Silvia Vilcekova
ZAZoran Apostoloski
Zoran Apostoloski
LMLudmila Meciarova
Ludmila Meciarova
Eva BurdováEva Burdová
Eva Burdová
JKJozef Kiseľák
Jozef Kiseľák
People who live in buildings are exposed to harmful effects of indoor air pollution for many years. Therefore, our research is aimed to investigate the indoor air quality in family houses. The measurements of indoor air temperature, relative humidity, total volatile organic compounds (TVOC), particulate matters (PM) and sound pressure level were carried out in 25 houses in several cities of the Republic of Macedonia. Mean values of indoor air temperature and relative humidity ranged from 18.9 °C to 25.6 °C and from 34.1% to 68.0%, respectively. With regard to TVOC, it can be stated that excessive occurrence was recorded. Mean values ranged from 50 μg/m3 to 2610 μg/m3. Recommended value (200 μg/m3) for human exposure to TVOC was exceeded in 32% of houses. Mean concentrations of PM2.5 (particular matter with diameter less than 2.5 μm) and PM10 (diameter less than 10 μm) are determined to be from 16.80 μg/m3 to 30.70 μg/m3 and from 38.30 μg/m3 to 74.60 μg/m3 individually. Mean values of sound pressure level ranged from 29.8 dB(A) to 50.6 dB(A). Dependence between characteristics of buildings (Year of construction, Year of renovation, Smoke and Heating system) and data from measurements (Temperature, Relative humidity, TVOC, PM2.5 and PM10) were analyzed using R software. Van der Waerden test shows dependence of Smoke on TVOC and PM2.5. Permutational multivariate analysis of variance shows the effect of interaction of Renovation and Smoke.

LMLudmila Meciarova
Ludmila Meciarova
Silvia VilcekovaSilvia Vilcekova
Silvia Vilcekova
Eva BurdováEva Burdová
Eva Burdová
JKJozef Kiselák
Jozef Kiselák
Thirty five Slovak households were selected for an investigation of indoor environmental quality. Measuring of indoor air physical and chemical factors and a questionnaire survey was performed during May 2017. The range of permissible operative temperature was not met in 11% of objects. Relative humidity met the legislative requirements in all monitored homes. Concentrations of total volatile organic compounds (TVOCs) were significantly higher in the apartments than in the family houses. The average TVOC levels in the apartments and family houses were 519.7 µg/m3 and 330.2 µg/m3, respectively. Statistical analysis confirmed the effect of indoor air temperature, relative humidity and particulate matter (PM0.5 and PM1) on the levels of TVOCs. Higher TVOC levels were observed also in homes where it is not a common practice to open windows during cleaning activities. Other factors that had a statistically significant effect on concentrations of volatile organic compounds were heating type, attached garage, location of the apartment within residential building (the floor), as well as number of occupants. Higher TVOC concentrations were observed in indoor than outdoor environment, while further analysis showed the significant impact of indoor emission sources on the level of these compounds in buildings. The questionnaire study showed a discrepancy between objective measurement and subjective assessment in the household environment, and pointed to insufficient public awareness about volatile organic compounds (VOCs).

2 August 2018 in International Journal of Environmental Health Research
Verified
Journal Article
Closed access
PKPeter Kapalo
Peter Kapalo
LMLudmila Meciarova
Ludmila Meciarova
Silvia VilcekovaSilvia Vilcekova
Silvia Vilcekova
Eva BurdováEva Burdová
Eva Burdová
FDFlorin Domnita
Florin Domnita
KPKinga-Eva Péterfi
Kinga-Eva Péterfi
This paper aims to carry out measurements of indoor air temperature, relative humidity and carbon dioxide (CO2) concentrations as well as to determine CO2 production by students and teacher during various physical activities. Two classrooms of Technical University of Kosice were selected for the research. Results of objective measurements confirmed strong correlation between CO2 concentration occupancy for all measurements. Recommended value for indoor CO2 level according to Pettenkofer (1,000 ppm) was exceeding in 60.9%. Results of this study showed the insufficient ventilation intensity in classrooms as well as obvious rise of CO2 concentration during the exams. The highest increase of CO2 was recorded during harder physical activity (run on the spot, squats, right and left side lunges, and rotating of the hips). Regarding CO2 production by respondents it can be see that it is visibly increased with increasing physical activity.

1 January 2017 in Procedia Engineering
Verified
Journal Article
Open access
Silvia VilcekovaSilvia Vilcekova
Silvia Vilcekova
PKPeter Kapalo
Peter Kapalo
ĽMĽudmila Mečiarová
Ľudmila Mečiarová
Eva BurdováEva Burdová
Eva Burdová
VIVeronika Imreczeová
Veronika Imreczeová

15 December 2017 in International Journal of Environmental Health Research
Verified
Journal Article
Closed access
LMLudmila Meciarova
Ludmila Meciarova
Silvia VilcekovaSilvia Vilcekova
Silvia Vilcekova
Eva BurdováEva Burdová
Eva Burdová
PKPeter Kapalo
Peter Kapalo
NMNikola Mihaľová
Nikola Mihaľová
Investigation of IEQ and subjective evaluation of IEQ by pupils is the main objective of this research work. For the monitoring two classrooms in primary school and two classrooms in art school were chosen. Very high CO2 levels were determined in both investigated schools. In three of four classrooms the statistically significant differences (p < 0.01) were reported between TVOC levels in autumn and spring. The recommended value for TVOC levels was exceeded in the range from 52 % to 53 % in autumn and from 52 % to 70 % in spring. Significant (p < 0.05) seasonal changes were found also for PM concentrations in each classroom. Significance difference in perception of IEQ factors between genders were observed for IAQ. This study showed a good consistency between data obtained from the measurement and data from the questionnaire study and thus, pointed to the good ability of pupils to evaluate the IEQ in their classrooms.