Evelina Jaselske

Dr. Evelina Jaselske

Kaunas University of Technology,Kaunas, Lithuania

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2022 in Gels
Verified
Journal Article
Open access
PDF file
LKLinas Kudrevicius
Linas Kudrevicius
EJEvelina Jaselske
Evelina Jaselske
DADiana Adliene
Diana Adliene
VRViktoras Rudzianskas
Viktoras Rudzianskas
ARAndrius Radziunas
Andrius Radziunas
ATArimantas Tamasauskas
Arimantas Tamasauskas
Highly precise dose delivery to the target (tumor or cancerous tissue) is a key point when brain diseases are treated applying recent stereotactic techniques: intensity-modulated, image-guided radiotherapy, volumetric modulated arc therapy, Gamma knife radiosurgery. The doses in one single shot may vary between tens and hundreds of Gy and cause significant cell/tissue/organ damages. This indicates the need for implementation of quality assurance (QA) measures which are realized performing treatment dose verification with more than one calibrated quality assurance method or tool, especially when functional radiosurgery with a high dose (up to 40 Gy in our case) shall be delivered to the target using small 4 mm collimator. Application of two dosimetry methods: radiochromic film dosimetry using RTQA2 and EBT3 films and dose gel dosimetry using modified nPAG polymer gels for quality assurance purposes in stereotactic radiosurgery treatments using Leksell Gamma Knife© Icon™ facility is discussed in this paper. It is shown that due to their polymerization ability upon irradiation nPAG gels might be potentially used as a quality assurance tool in Gamma knife radiosurgery: they indicate well pronounced linear dose response in hypo-fractionated (up to 10 Gy) dose range and are sensitive enough to irradiation dose changes with a high (at least 0.2 mm) spatial resolution. Dose assessment sensitivity of gels depends on parameters of a dose evaluation method (optical or magnetic resonance imaging), however, is similar to this estimated using film dosimetry, which is set as a standard dosimetry method for dose verification in radiotherapy.

19 June 2023 in Medicina
Verified
Journal Article
Open access
PDF file
SSSeverina Sediene
Severina Sediene
IKIlona Kulakiene
Ilona Kulakiene
BUBenas Gabrielis Urbonavičius
Benas Gabrielis Urbonavičius
EKErika Korobeinikova
Erika Korobeinikova
VRViktoras Rudzianskas
Viktoras Rudzianskas
EJElona Juozaitytė
Elona Juozaitytė
Background and Objectives: To our knowledge, this is the first study that investigated the prognostic value of radiomics features extracted from not only staging 18F-fluorodeoxyglucose positron emission tomography (FDG PET/CT) images, but also post-induction chemotherapy (ICT) PET/CT images. This study aimed to construct a training model based on radiomics features obtained from PET/CT in a cohort of patients with locally advanced head and neck squamous cell carcinoma treated with ICT, to predict locoregional recurrence, development of distant metastases, and the overall survival, and to extract the most significant radiomics features, which were included in the final model. Materials and Methods: This retrospective study analyzed data of 55 patients. All patients underwent PET/CT at the initial staging and after ICT. Along the classical set of 13 parameters, the original 52 parameters were extracted from each PET/CT study and an additional 52 parameters were generated as a difference between radiomics parameters before and after the ICT. Five machine learning algorithms were tested. Results: The Random Forest algorithm demonstrated the best performance (R2 0.963–0.998) in the majority of datasets. The strongest correlation in the classical dataset was between the time to disease progression and time to death (r = 0.89). Another strong correlation (r ≥ 0.8) was between higher-order texture indices GLRLM_GLNU, GLRLM_SZLGE, and GLRLM_ZLNU and standard PET parameters MTV, TLG, and SUVmax. Patients with a higher numerical expression of GLCM_ContrastVariance, extracted from the delta dataset, had a longer survival and longer time until progression (p = 0.001). Good correlations were observed between Discretized_SUVstd or Discretized_SUVSkewness and time until progression (p = 0.007). Conclusions: Radiomics features extracted from the delta dataset produced the most robust data. Most of the parameters had a positive impact on the prediction of the overall survival and the time until progression. The strongest single parameter was GLCM_ContrastVariance. Discretized_SUVstd or Discretized_SUVSkewness demonstrated a strong correlation with the time until progression.

26 July 2025 in Archives of Medical Science
Verified
Journal Article
Closed access
DLDanguole Laukaitiene
Danguole Laukaitiene
RVRoberta Vadeikiene
Roberta Vadeikiene
RURasa Ugenskiene
Rasa Ugenskiene
EJEvelina Jaselske
Evelina Jaselske
AVAntanas Vaitkus
Antanas Vaitkus
AIArturas Inciura
Arturas Inciura
Introduction: Radiotherapy is a vital therapeutic option in the treatment of breast cancer nowadays. However, a major obstacle to the full effectiveness of radiation therapy is still the radioresistance of cancer cells. Various studies have proven sulforaphane's (SFN) beneficial effects against cancer and its possible utilization as a radiosensitizer in radiotherapy. This study aimed to investigate whether SFN has a radiosensitizing effect on breast cancer cells.Material and methods: The anticancer efficiency of SFN and radiosensitizing effect in MCF-7 and MDA-MB-231 cell lines were assessed by the MTT assay. Using a flow cytometric assay, the apoptosis level and changes in the cell cycle were measured. RT-qPCR and Western blot analysis were used to determine BCL-2 and BCL-XL genes expresion and proteins level.Results: According to our results, SFN reduced the viability of cells, and combining SFN with radiation therapy (IR) caused much greater anticancer effects on cells. SFN+IR was shown to enhance the number of cells in the G2/M phase and the percentage of cells going through apoptosis. SFN reduced the expression of apoptosis-relative genes BCL-2 and BCL-XL. Consistent with this data, Western blot analysis revealed that BCL-2 and BCL-XL protein levels were decreased in tested cells. As a result of the combination treatment, the downregulation of the BCL-2 protein was observed only in MDA-MB-231 cells.Conclusions: These results indicate that SFN acts as a radiosensitizer by enhancing apoptotic cell death and reducing anti-apoptotic genes in breast cancer cells.

5 August 2026 in Medicina
Verified
Journal Article
Open access
PDF file
VRViktoras Rudzianskas
Viktoras Rudzianskas
EJEvelina Jaselske
Evelina Jaselske
JLJurgita Laurikaitienė
Jurgita Laurikaitienė
VŠVita Šimonytė-Verbickienė
Vita Šimonytė-Verbickienė
DADiana Adliene
Diana Adliene
Background and Objectives: Early-stage glottic cancer requires highly precise radiotherapy due to laryngeal motion and the proximity of critical structures. Magnetic resonance-guided radiotherapy (MRgRT) enables real-time visualization and motion management, potentially improving dose conformity while reducing treatment margins. This pilot comparative planning study compared the dosimetric characteristics of MR-guided intensity-modulated radiotherapy (IMRT) delivered on the Unity MR-linac with volumetric modulated arc therapy (VMAT) plans generated for the TrueBeam STx and Halcyon systems. Materials and Methods: Ten patients with T1–T2N0 glottic squamous cell carcinoma were included. For each patient, treatment plans prescribing 42.5 Gy in five fractions were generated using all three systems. Planning target volume (PTV) coverage, conformity index (CI), homogeneity index (HI), organ-at-risk (OAR) doses, monitor units, and beam-on times were compared using Friedman and post hoc Wilcoxon signed-rank tests. Results: Unity achieved superior dose conformity (CI 0.97 ± 0.01 vs. 0.78 ± 0.15 for TrueBeam STx and 0.58 ± 0.19 for Halcyon; p < 0.001) and the highest mean dose, while PTV coverage (D95% and D98%) was comparable to TrueBeam STx and higher than Halcyon. Reduced treatment margins resulted in significantly smaller PTV volumes (11.09 ± 3.87 cm3 vs. 17.43 ± 4.75 cm3; p = 0.0001). Halcyon demonstrated the most homogeneous dose distribution (HI 7.88 ± 3.14), whereas TrueBeam STx showed intermediate homogeneity (HI 12.81 ± 3.90). Most OAR dose metrics were comparable among techniques, although selected laryngeal structures and the esophagus differed significantly. Beam-on time was longest for Unity. Conclusions: MR-guided IMRT provided superior dose conformity while maintaining target coverage comparable to TrueBeam STx with clinically acceptable OAR sparing. Prospective clinical studies are required to determine whether these dosimetric advantages translate into improved patient outcomes.