Peter Kepplinger

Dr. Peter Kepplinger

Energy Research Centre, Vorarlberg University of Applied Sciences, Dornbirn, Vorarlberg, Austria
orcid
illwerke vkw Endowed Professorship for Energy Efficiency, He...

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2015 in Energy and Buildings
Verified
Journal Article
Closed access
Peter KepplingerPeter Kepplinger
Peter Kepplinger
GHGerhard Huber
Gerhard Huber
JPJörg Petrasch
Jörg Petrasch

1 September 2016 in Energy and Buildings
Verified
Journal Article
Closed access
Peter KepplingerPeter Kepplinger
Peter Kepplinger
GHGerhard Huber
Gerhard Huber
JPJörg Petrasch
Jörg Petrasch

18 December 2017 in Energies
Verified
Journal Article
Open access
PDF file
Bernhard FäßlerBernhard Fäßler
Bernhard Fäßler
MSMichael Schuler
Michael Schuler
MPMarkus Preißinger
Markus Preißinger
Peter KepplingerPeter Kepplinger
Peter Kepplinger
Due to the promoted integration of renewable sources, a further growth of strongly transient, distributed generation is expected. Thus, the existing electrical grid may reach its physical limits. To counteract this, and to fully exploit the viable potential of renewables, grid-balancing measures are crucial. In this work, battery storage systems are embedded in a grid simulation to evaluate their potential for grid balancing. The overall setup is based on a real, low-voltage distribution grid topology, real smart meter household load profiles, and real photovoltaics load data. An autonomous optimization routine, driven by a one-way communicated incentive, determines the prospective battery operation mode. Different battery positions and incentives are compared to evaluate their impact. The configurations incorporate a baseline simulation without storage, a single, central battery storage or multiple, distributed battery storages which together have the same power and capacity. The incentives address either market conditions, grid balancing, optimal photovoltaic utilization, load shifting, or self-consumption. Simulations show that grid-balancing incentives result in lowest peak-to-average power ratios, while maintaining negligible voltage changes in comparison to a reference case. Incentives reflecting market conditions for electricity generation, such as real-time pricing, negatively influence the power quality, especially with respect to the peak-to-average power ratio. A central, feed-in-tied storage performs better in terms of minimizing the voltage drop/rise and shows lower distribution losses, while distributed storages attached at nodes with electricity generation by photovoltaics achieve lower peak-to-average power ratios.

1 March 2019 in Thermal Science and Engineering Progress
Verified
Journal Article
Closed access
Peter KepplingerPeter Kepplinger
Peter Kepplinger
GHGerhard Huber
Gerhard Huber
MPMarkus Preißinger
Markus Preißinger
JPJörg Petrasch
Jörg Petrasch

1 February 2019 in Journal of Energy Storage
Verified
Journal Article
Closed access
Bernhard FäßlerBernhard Fäßler
Bernhard Fäßler
Peter KepplingerPeter Kepplinger
Peter Kepplinger
JPJ. Petrasch
J. Petrasch

29 June 2021 in Energies
Verified
Journal Article
Open access
PDF file
IMIreshika Muhandiram
Ireshika Muhandiram
RLRuben Lliuyacc-Blas
Ruben Lliuyacc-Blas
Peter KepplingerPeter Kepplinger
Peter Kepplinger
If left uncontrolled, electric vehicle charging poses severe challenges to distribution grid operation. Resulting issues are expected to be mitigated by charging control. In particular, voltage-based charging control, by relying only on the local measurements of voltage at the point of connection, provides an autonomous communication-free solution. The controller, attached to the charging equipment, compares the measured voltage to a reference voltage and adapts the charging power using a droop control characteristic. We present a systematic study of the voltage-based droop control method for electric vehicles to establish the usability of the method for all the currently available residential electric vehicle charging possibilities considering a wide range of electric vehicle penetrations. Voltage limits are evaluated according to the international standard EN50160, using long-term load flow simulations based on a real distribution grid topology and real load profiles. The results achieved show that the voltage-based droop controller is able to mitigate the under voltage problems completely in distribution grids in cases either deploying low charging power levels or exhibiting low penetration rates. For high charging rates and high penetrations, the control mechanism improves the overall voltage profile, but it does not remedy the under voltage problems completely. The evaluation also shows the controller’s ability to reduce the peak power at the transformer and indicates the impact it has on users due to the reduction in the average charging rates. The outcomes of the paper provide the distribution grid operators an insight on the voltage-based droop control mechanism for the future grid planning and investments.