9 October 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
FMFernando Moreno-Barbosa
Fernando Moreno-Barbosa
BABenito de Celis Alonso
Benito de Celis Alonso
EBEduardo Moreno Barbosa
Eduardo Moreno Barbosa
JHJavier Miguel Hernández-López
Javier Miguel Hernández-López
TGTheodore Geoghegan
Theodore Geoghegan
JRJosé Ramos-Méndez
José Ramos-Méndez
The aim of this work was to use TOPAS Monte Carlo simulations to model the effect of magnetic fields on dose distributions in brachytherapy lung treatments, under ideal and clinical conditions. Idealistic studies were modeled consisting of either a monoenergetic electron source of 432 keV, or a polyenergetic electron source using the spectrum of secondary electrons produced by 192Ir gamma-ray irradiation. The electron source was positioned in the center of a homogeneous, lung tissue phantom (ρ = 0.26 g/cm3). Conversely, the clinical study was simulated using the VariSource VS2000 192Ir source in a patient with a lung tumor. Three contoured volumes were considered: the tumor, the planning tumor volume (PTV), and the lung. In all studies, dose distributions were calculated in the presence or absence of a constant magnetic field of 3T. Also, TG-43 parameters were calculated for the VariSource and compared with published data from EGS-brachy (EGSnrc) and PENELOPE. The magnetic field affected the dose distributions in the idealistic studies. For the monoenergetic and poly-energetic studies, the radial distance of the 10% iso-dose line was reduced in the presence of the magnetic field by 64.9% and 24.6%, respectively. For the clinical study, the magnetic field caused differences of 10% on average in the patient dose distributions. Nevertheless, differences in dose-volume histograms were below 2%. Finally, for TG-43 parameters, the dose-rate constant from TOPAS differed by 0.09% ± 0.33% and 0.18% ± 0.33% with respect to EGS-brachy and PENELOPE, respectively. The geometry and anisotropy functions differed within 1.2% ± 1.1%, and within 0.0% ± 0.3%, respectively. The Lorentz forces inside a 3T magnetic resonance machine during 192Ir brachytherapy treatment of the lung are not large enough to affect the tumor dose distributions significantly, as expected. Nevertheless, large local differences were found in the lung tissue. Applications of this effect are therefore limited by the fact that meaningful differences appeared only in regions containing air, which is not abundant inside the human.

27 October 2026 in Progress in Additive Manufacturing
Verified
Journal Article
Open access
PDF file
RFRebeca Franco-Reyes
Rebeca Franco-Reyes
EBEduardo Moreno Barbosa
Eduardo Moreno Barbosa
ACAlonso Antonio Collantes-Gutiérrez
Alonso Antonio Collantes-Gutiérrez
BABenito de Celis Alonso
Benito de Celis Alonso
FMFernando Moreno-Barbosa
Fernando Moreno-Barbosa
RARICARDO Agustin-Serrano
RICARDO Agustin-Serrano
Anthropomorphic mannequins are widely used in biomedical research, medical imaging studies, and clinical training. However, commercial models are often expensive and have limitations in terms of anatomical customization. This study evaluates the feasibility and reproducibility of manufacturing a heterogeneous anthropomorphic mannequin using various polymeric materials via additive manufacturing with fused deposition modeling (FDM) technology. The size and shape are based on specific biometric measurements to emulate clinical situations. The mannequin is designed in three layers, and different 3D printing materials were selected for each tissue: silicone ink (skin), thermoplastic polyurethane (TPU, muscle), and acrylonitrile butadiene styrene (ABS, cortical and trabecular tissue). The novel aspect of this mannequin is the design of the trabecular structure, obtained from a mathematical model. Furthermore, a novel manufacturing methodology for the heterogeneous anthropomorphic structure of skeletal mannequins is presented. Morphological characterization from computed tomography (CT) images was used to evaluate the FDM manufacturing process and the resulting internal structures. Quantitative and qualitative analyses, including fractal dimension analysis and Hounsfield Unit (HU) measurements, were performed to assess the consistency of geometric complexity and the radiological response of the selected materials. The statistical analysis using a linear mixed-effects model (LMM) evaluated differences in fractal dimension among independently manufactured phantoms while accounting for the correlation among tomographic slices obtained from the same phantom. HU measurements provided a quantitative comparison between the selected materials and the corresponding human tissues. These results demonstrate the potential of FDM technology as an accessible alternative for manufacturing anatomical mannequins used in research and medical simulation applications.

15 January 2026 in AI
Verified
Journal Article
Open access
PDF file
FRFrancisco Joel Rojas-Pérez
Francisco Joel Rojas-Pérez
JSJosé Rubén Conde Sánchez
José Rubén Conde Sánchez
APAlejandra Morlett Paredes
Alejandra Morlett Paredes
FMFernando Moreno-Barbosa
Fernando Moreno-Barbosa
Julio Cesar Ramos-FernándezJulio Cesar Ramos-Fernández
Julio Cesar Ramos-Fernández
EPEucario Gonzalo Pérez-Pérez
Eucario Gonzalo Pérez-Pérez
The classification of breast cancer using machine learning techniques has become a critical tool in modern medical diagnostics. This study analyzes the performance of hybrid models that combine traditional machine learning algorithms (TMLAs) with a convolutional neural network (CNN)-based VGG16 model for feature extraction to improve accuracy for classifying eight breast cancer subtypes (BCS). The methodology consists of three steps. First, image preprocessing is performed on the BreakHis dataset at 400× magnification, which contains 1820 histopathological images classified into eight BCS. Second, the CNN VGG16 is modified to function as a feature extractor that converts images into representative vectors. These vectors constitute the training set for TMLAs, such as Random Forest (RF), Support Vector Machine (SVM), K-Nearest Neighbors (KNN), and Naive Bayes (NB), leveraging VGG16’s ability to capture relevant features. Third, k-fold cross-validation is applied to evaluate the model’s performance by averaging the metrics obtained across all folds. The results reveal that hybrid models leveraging a CNN-based VGG16 model for feature extraction, followed by TMLAs, achieve accuracy outstanding experimental accuracy. The KNN-based hybrid model stood out with a precision of 0.97, accuracy of 0.96, sensitivity of 0.96, specificity of 0.99, F1-score of 0.96, and ROC-AUC of 0.97. These findings suggest that, with an appropriate methodology, hybrid models based on TMLA have strong potential in classification tasks, offering a balance between performance and predictive capability.