Fernando Soares Schlindwein

Dr. Fernando Soares Schlindwein

University of Leicester, Leicester, UK
orcid

Research Focus & Metrics

Academic Career Length

39Years (1988-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2002 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
ABAnita Boardman
Anita Boardman
Fernando Soares SchlindweinFernando Soares Schlindwein
Fernando Soares Schlindwein
ARAna Paula Rocha
Ana Paula Rocha
ALArgentina Leite
Argentina Leite
Heart rate variability (HRV) has been used as a non-invasive marker of the activity of the autonomic nervous system and its spectrum analysis gives a measure of the sympatho-vagal balance. If short segments are used in an attempt to improve temporal resolution, autoregressive spectral estimation, where the mode] order must be estimated, is preferred. In this paper we compare four criteria for the estimation of the 'optimum' model order for an autoregressive (AR) process applied to short segments of tachograms used for HRV analysis. The criteria used were Akaike's final prediction error, Akaike's information criterion, Parzen's criterion of autoregressive transfer function and Rissanen's minimum description length method, and they were first applied to tachograms to verify (i) the range and distribution of model orders obtained and (ii) if the different techniques suggest the same model order for the same frames. The four techniques were then tested using a true AR process of known order p = 6; this verified the ability of the criteria to estimate the correct order of a true AR process and the effect, on the spectrum, of choosing a wrong model order was also investigated. It was found that all the four criteria underestimate the true AR order; specifying a fixed model order was then looked at and it is recommended that an AR order not less than p = 16, should be used for spectral analysis of short segments of tachograms.

1 May 1997 in Heart
Verified
Journal Article
Open access
PDF file
PSP. J. Stafford
P. J. Stafford
SKS. Kolvekar
S. Kolvekar
JCJ. Cooper
J. Cooper
JFJ. Fothergill
J. Fothergill
Fernando Soares SchlindweinFernando Soares Schlindwein
Fernando Soares Schlindwein
CGC. J. Garratt
C. J. Garratt
OBJECTIVE: To define the clinical value of the signal averaged P wave (SAPW) and to compare it with the standard electrocardiogram (ECG), echocardiogram, and clinical assessment for the prediction of atrial fibrillation after coronary bypass grafting (CABG). DESIGN: Prospective validation cohort study. SETTING: Regional cardiothoracic centre. PATIENTS: 201 unselected patients undergoing first elective CABG were recruited over six months. Patients requiring concomitant valve surgery were excluded. MAIN OUTCOME MEASURES: Age, sex, cardiothoracic ratio, and cardioactive drugs were noted. P wave specific SAPW recordings, ECG, and M mode echocardiograms from which left atrial diameter was measured were performed within 24 hours of surgery. Filtered P wave duration (SAPWD), spatial velocity, and energy were calculated from the SAPW. From the ECG, lead II P wave duration, P terminal force in lead V1, total P wave duration, and isoelectric interval were measured. Patients had Holter monitoring for 48 hours postoperatively and daily ECGs until discharge. RESULTS: Two patients died (1%) and 10 were unsuitable for analysis (5%). Of the remaining 189, 51 (27%) had atrial fibrillation (AF) lasting > 1 hour at a mean of 2 (0.5 to 7) days after CABG. Of the variables examined, only SAPWD (AF group 148 (SD 12), v 142 (14) ms, P = 0.008) and male sex (AF group 96%, v 78%, P < 0.01) were significantly different. A prospectively defined SAPWD of > 141 ms predicted atrial fibrillation with positive and negative predictive accuracies of 34% and 83%. Logistic regression analysis identified both male sex and SAPWD as significant independent predictors of postoperative atrial fibrillation. CONCLUSIONS: Signal averaged P wave duration was a better predictor of atrial fibrillation after coronary bypass grafting than standard electrocardiographic or echocardiographic criteria. The predictive value of this test is such that it is likely to be useful in the design of prospective trials of prophylactic antiarrhythmic treatment but is of limited use using current techniques in the clinical management of individual patients.

25 August 2022 in EP Europace
Verified
Journal Article
Closed access
PDF file
JBJoseph Barker
Joseph Barker
XLXin Li
Xin Li
SKSarah Khavandi
Sarah Khavandi
DKDavid Koeckerling
David Koeckerling
AMAkash Mavilakandy
Akash Mavilakandy
GNG. André Andre Ng
G. André Andre Ng
Most patients who receive implantable cardioverter defibrillators (ICDs) for primary prevention do not receive therapy during the lifespan of the ICD, whilst up to 50% of sudden cardiac death (SCD) occur in individuals who are considered low risk by conventional criteria. Machine learning offers a novel approach to risk stratification for ICD assignment. Systematic search was performed in MEDLINE, Embase, Emcare, CINAHL, Cochrane Library, OpenGrey, MedrXiv, arXiv, Scopus, and Web of Science. Studies modelling SCD risk prediction within days to years using machine learning were eligible for inclusion. Transparency and quality of reporting (TRIPOD) and risk of bias (PROBAST) were assessed. A total of 4356 studies were screened with 11 meeting the inclusion criteria with heterogeneous populations, methods, and outcome measures preventing meta-analysis. The study size ranged from 122 to 124 097 participants. Input data sources included demographic, clinical, electrocardiogram, electrophysiological, imaging, and genetic data ranging from 4 to 72 variables per model. The most common outcome metric reported was the area under the receiver operator characteristic (n = 7) ranging between 0.71 and 0.96. In six studies comparing machine learning models and regression, machine learning improved performance in five. No studies adhered to a reporting standard. Five of the papers were at high risk of bias. Machine learning for SCD prediction has been under-applied and incorrectly implemented but is ripe for future investigation. It may have some incremental utility in predicting SCD over traditional models. The development of reporting standards for machine learning is required to improve the quality of evidence reporting in the field.

2 November 2011 in Clinical Autonomic Research
Verified
Journal Article
Closed access
PDF file
WAWajid Aziz
Wajid Aziz
Fernando Soares SchlindweinFernando Soares Schlindwein
Fernando Soares Schlindwein
MWMichael Wailoo
Michael Wailoo
TBTaher Biala
Taher Biala
FRFederico Cardona Rocha
Federico Cardona Rocha

1 April 2009 in Mechanical Systems and Signal Processing
Verified
Journal Article
Closed access
YFYanhui Feng
Yanhui Feng
Fernando Soares SchlindweinFernando Soares Schlindwein
Fernando Soares Schlindwein

1 January 1990 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
Fernando Soares SchlindweinFernando Soares Schlindwein
Fernando Soares Schlindwein
DEDavid H. Evans
David H. Evans