Firas Khalid Alqarawi

Dr. Firas Khalid Alqarawi

Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 March 2022 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Mohammed GadMohammed Gad
Mohammed Gad
SASaleh Z. Alshehri
Saleh Z. Alshehri
SAShahad A. Alhamid
Shahad A. Alhamid
AAAlanoud Albarrak
Alanoud Albarrak
SQSoban Qadir
Soban Qadir
Firas Khalid AlqarawiFiras Khalid Alqarawi
Firas Khalid Alqarawi
This study aimed to evaluate the water sorption, solubility, and translucency of 3D-printed denture base resins (NextDent, FormLabs, and Asiga), compare them to heat-polymerized acrylic denture base resins, and assess their performance under the effects of thermal cycling. A total of 80 acrylic disc specimens were used in the current study, categorized into four groups (n = 10); in one group, the samples were fabricated conventionally with a heat-polymerizing process (control), while the other three groups were fabricated digitally from different 3D-printed reins (NextDent, FormLabs, and Asiga). Specimens were fabricated according to the manufacturers’ recommendations and immersed in distilled water for 48 h at 37 °C. Data on water sorption, solubility, and translucency measurements (T1) were obtained. All the specimens were subjected to 5000 thermal cycles, and then the measures were repeated using the same method (T2). Data analysis was attained via ANOVA and the post hoc Tukey test (α = 0.05). The type of resin significantly affected the values of water sorption, solubility, and translucency (p < 0.001). The water sorption of 3D-printed resins was increased significantly in comparison to control with or without a thermal cycling effect. In terms of solubility, a significant increase in 3D-printed resins before thermocycling was observed; however, after thermocycling, Asiga had a significantly low value compared to the other groups (p < 0.001). Thermal cycling increased the water sorption and solubility of all tested materials. In comparison to control, the translucency of the 3D-printed resins was significantly decreased (p < 0.001). The translucency was significantly decreased per material in terms of the thermal cycling effect (before and after). NextDent showed significantly low translucency values (p < 0.001) compared to the other groups. All 3D-printed resin groups had higher water sorption and solubility and lower translucency values in comparison to the heat-polymerized resin group. Regardless of resin types, thermal cycling adversely affected all tested properties.

28 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
EAEman M. AlHamdan
Eman M. AlHamdan
ABAmr Fahad Bashiri
Amr Fahad Bashiri
FAFaisal Alnashmi
Faisal Alnashmi
SASamar Al-Saleh
Samar Al-Saleh
KAKhalid Al-Shahrani
Khalid Al-Shahrani
TATariq Abduljabbar
Tariq Abduljabbar
The aim of the study was to assess the color matching ability and color stability of a single-shade resin-based composite (Omnichroma—OM) in comparison to a conventional dental composite. One hundred and sixty lower molar acrylic teeth in four different shades (B1, B2, A3, and C3) were prepared with class I cavities. Eighty teeth were divided into two groups based on the two resin composite materials (OM and Filtek Z-350 (FT)) for cavity restoration. Three groups were included in the color matching assessment, namely Gp 1-FT, Gp 2-OM-light cured (C), and Gp 3-OM-uncured (UC) groups. The color assessment was performed prior to cavity restoration and after cavity filling and before and after light curing to detect color matching. The 80 remaining teeth were restored with OM (n = 40) and FT (n = 40); half (n = 40) were submerged in coffee and the other half (n = 40) were submerged in cola for 2 weeks. The color stability was assessed by calculating material color (spectrophotometry) changes (∆E) before and after staining in immersion medium. The means and standard deviations of the ∆E values relating to color matching and color stability (stain resistance) among the study groups were analyzed using ANOVA and Tukey’s post hoc test. FT showed significantly better color matching (lower ΔE) in comparison to OM-UC specimens for shades B1, B2, and A3 (p < 0.01). Regarding the color stability in cola, the FT samples showed significantly lower ΔE values (indicating better color stability) compared to OM samples for all four shades (p < 0.01). The ΔE values of OM and FT samples in coffee were comparable (p > 0.01), showing comparable color stability. The color matching ability of the single-shade resin composite (OM) was influenced by the tooth color. The conventional resin composite showed better color matching than the single-shade composite (OM). The color stability of the single-shade resin composite (OM) was dependent on the staining medium. The OM composite showed more compromised color stability than the conventional resin composite in cola and comparable color stability to conventional resin composite in coffee.

1 September 2021 in Photodiagnosis and Photodynamic Therapy
Verified
Journal Article
Closed access
AAAasem M Alhenaki
Aasem M Alhenaki
Firas Khalid AlqarawiFiras Khalid Alqarawi
Firas Khalid Alqarawi
Azeem Ul Yaqin SyedAzeem Ul Yaqin Syed
Azeem Ul Yaqin Syed
FAFaris A Alshahrani
Faris A Alshahrani
FAFaris A. Alshahrani
Faris A. Alshahrani
TATariq Abduljabbar
Tariq Abduljabbar

12 May 2021 in Polymers
Verified
Journal Article
Open access
PDF file
Firas Khalid AlqarawiFiras Khalid Alqarawi
Firas Khalid Alqarawi
MAmazen alkahtany
mazen alkahtany
KAKhalid Almadi
Khalid Almadi
AGAfnan Ben Gassem
Afnan Ben Gassem
FAFaris A. Alshahrani
Faris A. Alshahrani
TATariq Abduljabbar
Tariq Abduljabbar
The present study aimed to synthesize and equate the mechanical properties and dentin interaction of two adhesives; experimental adhesive (EA) and 5 wt.% reduced graphene oxide rGO) containing adhesive. Scanning electron microscopy (SEM)-Energy-dispersive X-ray spectroscopy (EDX), Micro-Raman spectroscopy, push-out bond strength test, and Fourier Transform Infrared (FTIR) spectroscopy were employed to study nano-bond strength, degree of conversion (DC), and adhesive-dentin interaction. The EA was prepared, and rGO particles were added to produce two adhesive groups, EA-rGO-0% (control) and rGO-5%. The canals of sixty roots were shaped and prepared, and fiber posts were cemented. The specimens were further alienated into groups based on the root canal disinfection technique, including 2.5% sodium hypochlorite (NaOCl), Photodynamic therapy (PDT), and ER-CR-YSGG laser (ECYL). The rGO nanoparticles were flake-shaped, and EDX confirmed the presence of carbon (C). Micro-Raman spectroscopy revealed distinct peaks for graphene. Push-out bond strength test demonstrated highest values for the EA-rGO-0% group after NaOCl and PDT conditioning whereas, rGO-5% showed higher values after ECYL conditioning. EA-rGO-0% presented greater DC than rGO-5% adhesive. The rGO-5% adhesive demonstrated comparable push-out bond strength and rheological properties to the controls. The rGO-5% demonstrated acceptable DC (although lower than control group), appropriate dentin interaction, and resin tag establishment.

Verified
Journal Article
Open access
PDF file
Firas Khalid AlqarawiFiras Khalid Alqarawi
Firas Khalid Alqarawi
Three-dimensional printing is commonly used to fabricate provisional dental restorations. Studies have reported that changes in printing orientation affect the physical and mechanical properties of 3D-printed polymeric provisional restorations; however the findings have been inconsistent. Therefore, this systematic review and meta-analysis aims to analyze the articles evaluating the influence of printing orientation on the physical and mechanical properties of 3D-printed polymeric provisional dental restorations. Recommendations provided by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed to structure and compose the review. The PICO (Participant, Intervention, Comparison, Outcome) question ordered was: ‘Do 3D-printed provisional dental restorations (P) printed at various orientations (except 0°) (I) exhibit similar physical and mechanical properties (O) when compared to those printed at a 0° orientation (C)?’. An electronic search was conducted on 28 and 29 April 2025, by two independent researchers across four databases (MEDLINE/PubMed, Scopus, Cochrane Library, and Web of Science) to systematically collect relevant articles published up to March 2025. After removing duplicate articles and applying predefined inclusion and exclusion criteria, twenty-one articles were incorporated into this review. Self-designed Performa’s were used to tabulate all relevant information. For the quality analysis, the modified CONSORT scale was utilized. The quantitative analysis was performed on only fifteen out of twenty-one articles. It can be concluded that the printing orientation affects some of the tested properties, which include fracture strength (significantly higher for specimens printed at 0° when compared to 90°), wear resistance (significantly higher for specimens printed at 90° when compared to 0°), microhardness (significantly higher for specimens printed at 90°and 45° when compared to 0°), color stability (high at 0°), and surface roughness (significantly higher for specimens printed at 45° and 90° when compared to 0°). There were varied outcomes in terms of flexural strength and elastic modulus.

8 June 2022 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
FAFaris A. Alshahrani
Faris A. Alshahrani
SHShorouq Khalid Hamid
Shorouq Khalid Hamid
LALujain Ali Alghamdi
Lujain Ali Alghamdi
Firas Khalid AlqarawiFiras Khalid Alqarawi
Firas Khalid Alqarawi
Yousif A. Al-DulaijanYousif A. Al-Dulaijan
Yousif A. Al-Dulaijan
Mohammed GadMohammed Gad
Mohammed Gad
ZrO2 nanoparticles (ZNPs) have excellent physical properties. This study investigated the fracture load of implant-supported, fixed cantilevered prosthesis materials, reinforced with ZNPs and various polymerization techniques, compared with conventional and CAD/CAM materials. Sixty specimens were made from two CAD/CAM; milled (MIL) (Ceramill TEMP); and 3D-printed (NextDent Denture 3D+). Conventional heat-polymerized acrylic resin was used to fabricate the other specimens, which were grouped according to their polymerization technique: conventionally (HP) and autoclave-polymerized (AP); conventionally cured and reinforced with 5 wt% ZNPs (HPZNP); and autoclave reinforced with 5 wt% ZNPs (APZNP). The specimens were thermocycled (5000 cycles/30 s dwell time). Each specimen was subjected to static vertical loading (1 mm/min) using a universal Instron testing machine until fracture. Scanning electron microscopy was used for fracture surface analyses. The ANOVA showed significant fracture load differences between all the tested groups (p = 0.001). The Tukey post hoc tests indicated a significant difference in fracture load between all tested groups (p ˂ 0.001) except HP vs. HPZNP and AP vs. MIL. APZNP had the lowest mean fracture load value (380.7 ± 52.8 N), while MIL had the highest (926.6 ± 82.8 N). The CAD/CAM materials exhibited the highest fracture load values, indicating that they could be used in long-term interim prostheses. Autoclave polymerization improved fracture load performance, whereas ZrO2 nanoparticles decreased the fracture load performance of cantilevered prostheses.