This review looks at the implementation of magnetic-based approaches in surgical instruments for abdominal surgeries. As abdominal surgical techniques advance toward minimizing surgical trauma, surgical instruments are enhanced to support such an objective through the exploration of magnetic-based systems. With this design approach, surgical devices are given the capabilities to be fully inserted intraabdominally to achieve access to all abdominal quadrants, without the conventional rigid link connection with the external unit. The variety of intraabdominal surgical devices are anchored, guided, and actuated by external units, with power and torque transmitted across the abdominal wall through magnetic linkage. This addresses many constraints encountered by conventional laparoscopic tools, such as loss of triangulation, fulcrum effect, and loss/lack of dexterity for surgical tasks. Design requirements of clinical considerations to aid the successful development of magnetic surgical instruments, are also discussed.
19 April 2022 in IEEE Reviews in Biomedical Engineering
Tissue examination by hand remains an essential technique in clinical practice. The effective application depends on skills in sensorimotor coordination, mainly involving haptic, visual, and auditory feedback. The skills clinicians have to learn can be as subtle as regulating finger pressure with breathing, choosing palpation action, monitoring involuntary facial and vocal expressions in response to palpation, and using pain expressions both as a source of information and as a constraint on physical examination. Patient simulators can provide a safe learning platform to novice physicians before trying real patients. This paper reviews state-of-the-art medical simulators for the training for the first time with a consideration of providing multimodal feedback to learn as many manual examination techniques as possible. The study summarizes current advances in tissue examination training devices simulating different medical conditions and providing different types of feedback modalities. Opportunities with the development of pain expression, tissue modeling, actuation, and sensing are also analyzed to support the future design of effective tissue examination simulators.
30 January 2013 in Medical & Biological Engineering & Computing
This paper proposes an electromagnetic-based local magnetic actuation (LMA) as a novel actuation system for cases where it is required to actuate a mechanical system across a physical barrier. The main motivation for LMA is in the area of minimally invasive robotic surgery, where it is desired to actuate the surgical manipulators across the abdominal wall. In the local electromagnetic actuation approach, it is proposed that the magnetic field is produced by a pair of electromagnetic stators, acting across a physical barrier (the abdominal wall), and interacts with the magnetic field of the permanent magnet rotor on the other side of the barrier. The mathematical model of the electromechanical system is developed by exploiting the principles of synchronous motors. A control strategy was then developed to regulate the rotor speed in the presence of model uncertainties, load disturbances, and axes misalignment. Furthermore, the performance of the controllers is evaluated in two cases, with a Hall effect sensor embedded internally in the abdominal cavity close to the permanent magnet rotor and placed externally to the abdominal cavity close to the stators. The main contribution is the application of electromagnetic strategies in the unique setting of rotor actuation across a physical wall, focusing mainly on the dynamics modeling of the resulting structure and evaluation of its performance for surgical application. The proposed model and actuation strategies allow robust control of the desired speed and torque of the internal rotor, and this is demonstrated through experiments.
Robotic patients show great potential for helping to improve medical palpation training, as they can provide feedback that cannot be obtained in a real patient. They provide information about internal organ deformation that can significantly enhance palpation training by giving medical trainees visual insight based on the pressure they apply for palpation. This can be achieved by using computational models of abdomen mechanics. However, such models are computationally expensive, and thus unable to provide real-time predictions. In this work, we proposed an innovative surrogate model of abdomen mechanics by using machine learning (ML) and finite element (FE) modelling to virtually render internal tissue deformation in real time. We first developed a new high-fidelity FE model of the abdomen mechanics from computerized tomography (CT) images. We performed palpation simulations to produce a large database of stress distribution on the liver edge, an area of interest in most examinations. We then used artificial neural networks (ANNs) to develop the surrogate model and demonstrated its application in an experimental palpation platform. Our FE simulations took 1.5 h to predict stress distribution for each palpation while this only took a fraction of a second for the surrogate model. Our results show that our artificial neural network (ANN) surrogate has an accuracy of 92.6%. We also showed that the surrogate model is able to use the experimental input of palpation location and force to provide real-time projections onto the robotics platform. This enhanced robotics platform has the potential to be used as a training simulator for trainees to hone their palpation skills.
1 January 2021 in IEEE Robotics and Automation Letters
Physicians use pain expressions shown in a patient's face to regulate their palpation methods during physical examination. Training to interpret patients’ facial expressions with different genders and ethnicities still remains a challenge, taking novices a long time to learn through experience. This letter presents MorphFace: a controllable 3D physical-virtual hybrid face to represent pain expressions of patients from different ethnicity-gender backgrounds. It is also an intermediate step to expose trainee physicians to the gender and ethnic diversity of patients. We extracted four principal components from the Chicago Face Database to design a four degrees of freedom (DoF) physical face controlled via tendons to span $\sim\!85\%$ of facial variations among gender and ethnicity. Details such as skin colour, skin texture, and facial expressions are synthesized by a virtual model and projected onto the 3D physical face via a front-mounted LED projector to obtain a hybrid controllable patient face simulator. A user study revealed that certain differences in ethnicity between the observer and the MorphFace lead to different perceived pain intensity for the same pain level rendered by the MorphFace. This highlights the value of having MorphFace as a controllable hybrid simulator to quantify perceptual differences during physician training.