Francesco Di Rienzo

Dr. Francesco Di Rienzo

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2022 in IEEE Access
Verified
Journal Article
Open access
GGGionatan Gallo
Gionatan Gallo
Francesco Di RienzoFrancesco Di Rienzo
Francesco Di Rienzo
FGFederico Garzelli
Federico Garzelli
Pietro DucangePietro Ducange
Pietro Ducange
Carlo VallatiCarlo Vallati
Carlo Vallati
Real-time object detection is currently used to automate various tasks in industrial environments. One of the most important tasks is to improve the safety of workers by monitoring the correct use of Personal Protective Equipment (PPE) in dangerous areas. In this context, usually, a monitoring system analyzes the stream of videos from surveillance cameras to assess PPE usage in real time. When a worker not wearing the appropriate PPE is detected, an acoustic or visual alarm is triggered automatically to raise attention and awareness. The solutions proposed so far are mostly cloud-based systems: images from the site are continuously offloaded to the cloud for analysis. This centralized architecture requires significant network bandwidth to transmit the video feeds through an internet connection that must be reliable, as a network outage would disrupt the service. In this work, we propose a system for real-time PPE detection based on video streaming analysis and Deep Neural Network (DNN). We adopt the edge computing model in which the application for image analysis and classification is deployed on an embedded system installed in proximity of the camera and directly connected to it. The system does not require continuous image transmission towards a cloud system, thus ensuring bandwidth efficiency, reliability, and workers’ privacy. A prototype of the proposed system is developed exploiting a low-cost commercial embedded system, i.e. a Raspberry PI, equipped with an Intel Neural Compute Stick 2. We tested the system with five different pre-trained convolutional neural networks (CNNs), fine-tuned to detect different PPEs, namely helmets, vests, and gloves. In our experimental evaluation, we first compared the five CNNs in terms of classification performance and inference latency. Then, we deployed each CNN on the real system and evaluated the system’s throughput regarding the number of video frames analyzed each second.

1 July 2019 in Microchemical Journal
Verified
Journal Article
Closed access
NPN. Poma
N. Poma
FVF. Vivaldi
F. Vivaldi
ABandrea bonini
andrea bonini
NCN. Carbonaro
N. Carbonaro
Francesco Di RienzoFrancesco Di Rienzo
Francesco Di Rienzo
Fabio Di FrancescoFabio Di Francesco
Fabio Di Francesco

24 June 2020 in IEEE Journal of Radio Frequency Identification
Verified
Journal Article
Closed access
Francesco Di RienzoFrancesco Di Rienzo
Francesco Di Rienzo
AVAntonio Virdis
Antonio Virdis
Carlo VallatiCarlo Vallati
Carlo Vallati
NCNicola Carbonaro
Nicola Carbonaro
Alessandro TognettiAlessandro Tognetti
Alessandro Tognetti
Biomedical systems that aim at monitoring parameters over a long period of time will require non-invasive wearable devices. A wide range of applications, including continuous workers monitoring or daily monitoring of patients, is expected to exploit wearable devices, each one characterized by different requirements. Such devices will adopt a design that minimizes discomfort and does not limit users’ mobility to allow round-the-clock wearability. In order to ensure a significant reduction in the size of wearable devices, the next generation of this technology will need no batteries or at least very small ones. In this paper we analyze the use of Near Field Communication (NFC) for ultra-low-power communication in wearable devices for biomedical applications. Our goal is to verify whether NFC technology can support the heterogeneous requirements of different biomedical use-cases. For this purpose, we will first provide a review of the current state of the art in NFC-Enabled solutions. Then, we will evaluate NFC capabilities through a set of experiments, using off-the-shelf devices. We will pose particular focus on the energy harvesting capabilities to evaluate the feasibility of designing battery-less devices. Our results show that NFC adoption in different biomedical applications is possible, as they can ensure proper reading frequency and distance. Finally, we further demonstrate this through a proof-of-concept implementation: an NFC-based sensorized glove for work safety that is able to monitor the external temperature in a continuous manner.

1 August 2021
Verified
Conference Paper
Closed access
GGGionatan Gallo
Gionatan Gallo
Francesco Di RienzoFrancesco Di Rienzo
Francesco Di Rienzo
PDPietro Ducange
Pietro Ducange
VFVincenzo Ferrari
Vincenzo Ferrari
ATAlessandro Tognetti
Alessandro Tognetti
CVCarlo Vallati
Carlo Vallati
The adoption of real-time object detection systems via video streaming analysis is currently exploited in several contexts, from security monitoring to safety prevention. In industrial environments, proper usage of Personal Protective Equipment (PPE) is paramount to ensure workers’ safety. However, the use of some types of PPE, such as helmets, is often neglected by workers, especially in indoor areas. Thus, in order to reduce the risks of accidents, real-time video streaming-based monitoring systems may be used to monitor areas in which workers operate and alert them not to wear PPEs via acoustic alarms or visual signals. In case of a remote analysis, there are potential issues related to the high rate of data streams to be transported and analyzed and workers’ privacy. In this work, we propose an embedded smart system for real-time PPE detection based on video streaming analysis and deep learning models. We discuss the deployment of different versions of the YOLOv4 network fine-tuned using a public PPE dataset. In the end, we assess the performance of the proposed system in terms of accuracy and latency and of the overall PPE detection procedure.

24 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
NCNicola Carbonaro
Nicola Carbonaro
LALucia Arcarisi
Lucia Arcarisi
Carlotta MarinaiCarlotta Marinai
Carlotta Marinai
Marco LaurinoMarco Laurino
Marco Laurino
Francesco Di RienzoFrancesco Di Rienzo
Francesco Di Rienzo
Alessandro TognettiAlessandro Tognetti
Alessandro Tognetti
We describe the development and preliminary evaluation of an innovative low-cost wearable device for gait analysis. We have developed a sensorized sock equipped with 32 piezoresistive textile-based sensors integrated in the heel and metatarsal areas for the detection of signals associated with the contact pressures generated during walking phases. To build the sock, we applied a sensing patch on a commercially available sock. The sensing patch is a stretchable circuit based on the resistive matrix method, in which conductive stripes, based on conductive inks, are coupled with piezoresistive fabrics to form sensing elements. In our sensorized sock, we introduced many relevant improvements to overcome the limitations of the classical resistive matrix method. We preliminary evaluated the sensorized sock on five healthy subjects by performing a total of 80 walking tasks at different speeds for a known distance. Comparison of step count and step-to-step frequency versus reference measurements showed a high correlation between the estimated measure and the real one.

17 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MZMichele Zanoletti
Michele Zanoletti
PBPasquale Bufano
Pasquale Bufano
FBFrancesco Bossi
Francesco Bossi
Francesco Di RienzoFrancesco Di Rienzo
Francesco Di Rienzo
CMCarlotta Marinai
Carlotta Marinai
Alessandro TognettiAlessandro Tognetti
Alessandro Tognetti
Assessing mobility in daily life can provide significant insights into several clinical conditions, such as Chronic Obstructive Pulmonary Disease (COPD). In this paper, we present a comprehensive analysis of wearable devices’ performance in gait speed estimation and explore optimal device combinations for everyday use. Using data collected from smartphones, smartwatches, and smart shoes, we evaluated the individual capabilities of each device and explored their synergistic effects when combined, thereby accommodating the preferences and possibilities of individuals for wearing different types of devices. Our study involved 20 healthy subjects performing a modified Six-Minute Walking Test (6MWT) under various conditions. The results revealed only little performance differences among devices, with the combination of smartwatches and smart shoes exhibiting superior estimation accuracy. Particularly, smartwatches captured additional health-related information and demonstrated enhanced accuracy when paired with other devices. Surprisingly, wearing all devices concurrently did not yield optimal results, suggesting a potential redundancy in feature extraction. Feature importance analysis highlighted key variables contributing to gait speed estimation, providing valuable insights for model refinement.