Marco Galeazzi

Dr. Marco Galeazzi

Cardiologia Clinica e Riabilitativa - Ospedale San Filippo Neri, Rome, Lazio, Italy
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AMAndrea Matteucci
Andrea Matteucci
MRMaurizio Russo
Maurizio Russo
MGMarco Galeazzi
Marco Galeazzi
CPClaudio Pandozi
Claudio Pandozi
MBMichela Bonanni
Michela Bonanni
FCFurio Colivicchi
Furio Colivicchi
Background: Catheter ablation is a first-line treatment for rhythm control strategies in patients with atrial fibrillation (AF), with different energy sources available, including pulsed-field ablation (PFA), high-power short-duration radiofrequency (HPSD RF), conventional radiofrequency (RF), and cryoballoon ablation. Limited evidence exists on how different ablation techniques affect patient-reported outcomes, such as patients’ quality of life (QoL) and perceived symptoms. This study aims to assess the impact of ablation energy sources on reported QoL and symptom perception after AF ablation. Methods: The study included 148 patients who underwent catheter ablation in different centers. Patients were divided into four groups according to the energy source used. Follow-up was conducted during the 6 months post-procedure. Patients were asked to complete a 20-item questionnaire evaluating quality of life, activity resumption, recovery process, perceived symptoms, and satisfaction. Comparative analyses were performed across energy groups, anesthesia types, and anesthetic drugs. Results: PFA patients reported the highest improvement in QoL scores compared to RF, HPSD RF, and cryoablation (p < 0.001). Activity resumption and symptom relief were significantly better in the PFA group compared to others (p < 0.001). Anesthesia type and anesthetic drug influenced QoL outcomes, with patients under general anesthesia showing higher QoL scores compared to deep sedation (p < 0.001). The energy source and anesthetic drug resulted in independent predictors of QoL improvement. Conclusions: Ablation energy source could impact patients’ perceived QoL and symptom relief after AF ablation. PFA demonstrated superior performance scores in QoL and symptom perception compared to other techniques. Anesthetic drugs also play a role in patient-reported outcomes and activity resumption.

Verified
Journal Article
Open access
PDF file
AMAndrea Matteucci
Andrea Matteucci
CPCarlo Pignalberi
Carlo Pignalberi
CPClaudio Pandozi
Claudio Pandozi
BMBarbara Magris
Barbara Magris
AMAntonella Meo
Antonella Meo
FCFurio Colivicchi
Furio Colivicchi
The implantation of cardiac electronic devices (CIEDs), including pacemakers and defibrillators, has become increasingly prevalent in recent years and has been accompanied by a significant rise in cardiac device infections (CDIs), which pose a substantial clinical and economic burden. CDIs are associated with hospitalizations and prolonged antibiotic therapy and often necessitate device removal, leading to increased morbidity, mortality, and healthcare costs worldwide. Approximately 1–2% of CIED implants are associated with infections, making this a critical issue to address. In this contemporary review, we discuss the burden of CDIs with their risk factors, healthcare costs, prevention strategies, and clinical management.


Verified
Journal Article
Open access
PDF file
AMAndrea Matteucci
Andrea Matteucci
CPClaudio Pandozi
Claudio Pandozi
MRMaurizio Russo
Maurizio Russo
MGMarco Galeazzi
Marco Galeazzi
GSGiammarco Schiaffini
Giammarco Schiaffini
FCFurio Colivicchi
Furio Colivicchi
The exploration of the cardiac conduction system evolved over a century, marked by groundbreaking discoveries in atrioventricular (AV) nodal physiology. Atrioventricular nodal re-entrant tachycardia (AVNRT), the most prevalent regular tachycardia in humans, remains enigmatic despite extensive research. Detailed examinations of AV nodal anatomy and histology reveal variations in location and shape, influencing electrophysiological properties. Variability in AV nodal extensions and their embryological origins contribute to the complexity of the conduction system. Physiologically, the AV node plays a crucial role in modulating AV conduction, introducing delays for ventricular filling and filtering atrial impulses. Dual-pathway physiology involving fast and slow pathways further complicates AVNRT circuitry. Integrated approaches combining pre-procedural imaging with electroanatomical mapping enhance our understanding of AV nodal structures and high-definition mapping improves precision in identifying ablation targets. Electrophysiological–anatomical correlations may unveil the specific roles of conduction axis components, aiding in the optimization of ablation strategies. This review traces the historical journey from Tawara’s pioneering work to recent integrated approaches aimed at unraveling the intricacies of AV nodal structures while emphasizing the importance of a multidimensional approach, incorporating technological advancements, anatomical understanding, and clinical validation in human mapping studies.

30 June 2014 in Journal of Atrial Fibrillation
Verified
Journal Article
Closed access
CPClaudio Pandozi
Claudio Pandozi
FGFranco Di Gregorio
Franco Di Gregorio
CLCarlo Lavalle
Carlo Lavalle
RRRenato Pietro Ricci
Renato Pietro Ricci
SFSabina Ficili
Sabina Ficili
MSMassimo Santini
Massimo Santini
The discrimination between ventricular (VT) and supraventricular tachycardia (SVT) and the evaluation of their hemodynamic impact are essential issues in the arrhythmia management. A new pacing device features a tachycardia diagnostic system relying on simultaneous recording of the transvalvular impedance (TVI) and a special integrated electric signal derived by the whole set of endocardial electrodes (iECG). The iECG waveform is sensitive to the pattern of ventricular activation, similarly to the surface ECG. The TVI increases in systole and decreases in diastole and the amplitude of this cyclic fluctuation is an expression of the effectiveness of the pump function. In order to test the value of these signals in the analysis of a tachycardia, we have assessed the iECG and TVI modifications induced by different SVTs and tolerated and non-tolerated VTs, during electrophysiological (EP) studies. In case of SVT, the ventricular component of the iECG maintained the same morphology as in sinus rhythm. The peak-peak amplitude of the TVI fluctuation was reduced to 66 ± 11 % of the individual sinus rhythm reference, but the signal was present at every beat and showed a remarkable stability (variation coefficient 0.19 ± 0.01). In case of VT, the ventricular component of the iECG was strikingly different than in sinus rhythm. Regular TVI fluctuation was observed with tolerated VTs (peak-peak amplitude 74 ± 6 %; variation coefficient 0.21 ± 0.04). In contrast, with non-tolerated VTs the TVI amplitude was depressed below 40%, and the signal was virtually absent in the event of very fast VT or VF. Our results confirm that the iECG is a reliable tool to quickly discriminate VTs from SVTs and that TVI can provide information on the severity of the hemodynamic impairment produced by a tachycardia, with potential clinical benefit in the follow-up of pacemaker patients. Furthermore, the application of these signals to automatic algorithms of arrhythmia recognition might improve the specificity of therapy administration by an implantable defibrillator (ICD).

Verified
Journal Article
Open access
PDF file
AMAndrea Matteucci
Andrea Matteucci
EMEnrico Maggio
Enrico Maggio
DDDomenico Dardani
Domenico Dardani
MRMaurizio Russo
Maurizio Russo
MGMarco Galeazzi
Marco Galeazzi
FCFurio Colivicchi
Furio Colivicchi
Atrioventricular (AV) node ablation represents an established therapeutic option in the management of atrial fibrillation (AF) and other atrial tachyarrhythmias, particularly in patients with symptomatic tachycardia who remain unresponsive or intolerant to pharmacological therapy. The procedure is often considered in cases of refractory arrhythmias, antiarrhythmic drugs intolerance, or tachycardiomyopathy, and plays a key role in optimizing outcomes in patients undergoing cardiac resynchronization therapy, where achieving adequate biventricular pacing is otherwise compromised by rapid ventricular responses. Traditionally, AV node ablation is performed using radiofrequency energy delivered at the region of the His bundle, guided by the earliest His potential recordings. However, the anatomical complexity of the AV node and Koch’s triangle poses important challenges, including the risk of incomplete ablation, persistence of conduction, lack of reliable junctional escape rhythms, and increased risk of proarrhythmia. Recent advances in high-resolution mapping and electroanatomical guidance have enabled a more precise anatomical approach, selectively targeting the compact AV node while reducing collateral injury. These developments offer the potential for improved procedural safety, long-term efficacy, and a more standardized strategy for patient management. This review summarizes current evidence, techniques, and clinical implications of AV node ablation, highlighting its role in the evolving landscape of arrhythmia treatment.