Gavin Gillmore

Prof. Gavin Gillmore

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2001 in Ecotoxicology and Environmental Safety
Verified
Journal Article
Closed access
Gavin GillmoreGavin Gillmore
Gavin Gillmore
PPPaul Phillips
Paul Phillips
ADAntony Denman
Antony Denman
MSMalcolm Sperrin
Malcolm Sperrin
GPGillian Pearce
Gillian Pearce

3 October 2017 in Materials
Verified
Journal Article
Open access
PDF file
OAOthman Al-Khudairi
Othman Al-Khudairi
HHHomayoun Hadavinia
Homayoun Hadavinia
CLChristian Little
Christian Little
Gavin GillmoreGavin Gillmore
Gavin Gillmore
PGPeter Greaves
Peter Greaves
KDKirsten Dyer
Kirsten Dyer
In this paper, the sensitivity of the structural integrity of wind turbine blades to debonding of the shear web from the spar cap was investigated. In this regard, modal analysis, static and fatigue testing were performed on a 45.7 m blade for three states of the blade: (i) as received blade (ii) when a crack of 200 mm was introduced between the web and the spar cap and (iii) when the crack was extended to 1000 mm. Calibration pull-tests for all three states of the blade were performed to obtain the strain-bending moment relationship of the blade according to the estimated target bending moment (BM) which the blade is expected to experience in its service life. The resultant data was used to apply appropriate load in the fatigue tests. The blade natural frequencies in flapwise and edgewise directions over a range of frequency domain were found by modal testing for all three states of the blade. The blade first natural frequency for each state was used for the flapwise fatigue tests. These were performed in accordance with technical specification IEC TS 61400-23. The fatigue results showed that, for a 200 mm crack between the web and spar cap at 9 m from the blade root, the crack did not propagate at 50% of the target BM up to 62,110 cycles. However, when the load was increased to 70% of target BM, some damages were detected on the pressure side of the blade. When the 200 mm crack was extended to 1000 mm, the crack began to propagate when the applied load exceeded 100% of target BM and the blade experienced delaminations, adhesive joint failure, compression failure and sandwich core failure.

1 January 2007 in Environment International
Verified
Journal Article
Closed access
ADA.R. Denman
A.R. Denman
RCR.G.M. Crockett
R.G.M. Crockett
CGC.J. Groves-Kirkby
C.J. Groves-Kirkby
PPP.S. Phillips
P.S. Phillips
Gavin GillmoreGavin Gillmore
Gavin Gillmore
AWA.C. Woolridge
A.C. Woolridge

1 July 2000 in Ecotoxicology and Environmental Safety
Verified
Journal Article
Closed access
Gavin GillmoreGavin Gillmore
Gavin Gillmore
MSMalcom Sperrin
Malcom Sperrin
PPPaul Phillips
Paul Phillips
ADAntony Denman
Antony Denman

1 January 2005 in Journal of Environmental Radioactivity
Verified
Journal Article
Closed access
Gavin GillmoreGavin Gillmore
Gavin Gillmore
PPPaul S. Phillips
Paul S. Phillips
ADAntony R. Denman
Antony R. Denman

15 August 2006 in Science of The Total Environment
Verified
Journal Article
Closed access
CGC.J. Groves-Kirkby
C.J. Groves-Kirkby
ADA.R. Denman
A.R. Denman
RCR.G.M. Crockett
R.G.M. Crockett
PPP.S. Phillips
P.S. Phillips
Gavin GillmoreGavin Gillmore
Gavin Gillmore