Three-dimensional numerical simulations were carried out to investigate the flow dynamic behavior and pressure characteristics of a variable force solenoid (VFS) valve used in automatic transmissions. To visualize the dynamic movement of the spool, a moving mesh with dynamic layering meshes for varying boundary conditions was employed. Relevant experiment was performed to validate the simulations. The VFS valve was characterized by determining the variation in the equivalent orifice area with the spool displacement. The pressure sensitivity was found to be precisely controlled by the relation between the depth and the area of the notch in the range of the characteristic length of the valve. The results of model C, which takes into account both seal leakage and notches, indicate that there are linear pressure sensitivities in the range of the valve overlap and that there are smooth pressure control characteristics in the range of the two notches. The VFS valve with a spool was shown to have an unavoidable and unique hysteresis, which is caused by the nonlinear electromagnetic forces at the end of strokes of the spool and by the friction forces in the valve overlap. The effects of varying the oil temperature on the pressure sensitivity curves and the seal leakage flow rates were also examined.
A multiphysics analysis of a linear control solenoid valve coupled with a single degree of freedom (DOF) system is performed to analyze the spool behaviors of the valve. Axially symmetrical simulations are carried out to investigate simultaneously the phenomena of the electromagnetic field and the flow field. The valve spool stroke is determined by the balance between the forces, i.e., the electromagnetic force, hydraulic force, spring force, and damping force. In turn, the spool stroke influences these forces. The arbitrary Lagrangian–Eulerian (ALE) method is employed to describe the dynamic behavior of the system. The simulation results are compared with experimental data to ascertain their accuracy and reliability. In static electromagnetic simulations, a constant electromagnetic force can arise in the linear control solenoid valve because of the leakage of the magnetic flux at the core pole. In the multiphysics simulations, the controllable range of the valve is found to be i = 0.2 – 1.1 A, which is twice the size of that of the electromagnetic simulations. The hydraulic force due to the feedback pressure pushes the spool forward and enables a wider controllable range. Although the supplied pressure improves the system linearity, a critical supplied pressure is required to ensure the linearity of the linear control solenoid valve. The effects of varying the rising time and the maximum external current on the behavior of the valve and its pressure sensitivities are examined.
In this paper, a nozzle flow model was used to design an injector nozzle and obtain initial spray conditions for the dimethyl ether (DME) common rail-injection system. In order to deliver the same amount of energy as that provided by diesel at a low injection pressure of 50 MPa, the injector for DME needs nozzle holes with larger diameters and a higher SAC volume for the same injection duration. In addition, the needle lift and needle seat diameter should be increased to maintain a minimum flow area ratio. Although the vapour pressure and maximum injection pressure of DME are lower than those of diesel, the nozzle in a DME system showed higher discharge coefficients and effective nozzle exit diameters for the same injection duration owing to low kinematic viscosity. However, because the maximum injection pressure in DME is lower than that with diesel, and the length of the cavitation region is narrower.
The dynamic behavior and thermal performance of a high-power, high-energy-density lithium-ion battery for urban air mobility (UAM) applications were analyzed by using an electro-thermal model. To simulate the behavior of pouch-type nickel-cobalt-manganese (NCM) lithium–ion batteries, a battery equivalent circuit with a second order of resistance–capacitance (RC) elements was employed. The values of the RC models were determined by using curve fitting based on experimental data for the lithium-ion battery. A three–dimensional model of the lithium-ion battery was created, and a thermal analysis was performed while considering the external temperature and flight time under a 20 min load condition. At an external temperature of 20 °C, the heat generation increased proportionally to the square of the current as the C–rate increased. For 3C, the reaction heat source was 45.5 W, and the average internal temperature of the cell was 36 °C. Even at the same 3C, as the external temperature decreased to 0 °C, the increase in internal resistance led to a greater reaction heat source of 58.27 W, which was 36.9% higher than that at 20 °C. At 5C, the maximum operating time was 685.6 s. At this point, the average internal temperature of the cell was 59.8 °C, which allowed for normal operation. When the C–rate of the battery cell reached 8, which was the momentary maximum high-discharge condition, the temperature sharply rose before the state of charge () reached 0. With an average internal cell temperature of 80 °C, the maximum operating time became 111.9 s. This met the design requirements for urban air mobility (UAM) in this study.
This study examines the thermal behavior of lithium-ion battery modules intended for Urban Air Mobility (UAM), a forthcoming urban transport system designed to facilitate efficient and secure passenger and cargo transport within city centers. UAM applications necessitate batteries with high energy densities capable of sustaining elevated discharge rates during critical phases such as takeoff and landing. The battery module evaluated in this study comprises four cells arranged in series and configured as a submodule for UAM applications. A three-dimensional thermal model was utilized to analyze the impact of external temperature fluctuations and high discharge rates on the performance of the battery module. The numerical findings indicated considerable variations in temperature and internal resistance among the cells, especially under high discharge rates at low temperatures, with a maximum temperature deviation of 32.952 °C observed at an 8 C discharge rate. These thermal non-uniformities were attributed to variations in cell capacity and internal resistance, which were amplified by manufacturing inconsistencies and operational conditions. The study underscores the necessity of robust thermal management strategies to mitigate the risk of thermal runaway and ensure the operational safety and reliability of UAM systems. The results emphasize the critical role of advanced Battery Management Systems (BMS) in monitoring and controlling cell voltage and temperature to achieve consistent performance across the battery module. This research contributes valuable insights into the design of more efficient and reliable battery modules for UAM, highlighting the importance of addressing cell-to-cell performance discrepancies to enhance overall module efficacy and durability.
A rotating body consisting of a rotating shaft and bearings inevitably generates voltage and current. The potential difference between the bearing and the shaft is the main cause of electrical corrosion, which causes motor failure, shortened bearing life, and many safety issues. To prevent corrosion, passive shaft-grounding devices use conductive materials and brushes; however, these devices cannot be completely grounded, so there is a difference in local potential, and brush friction generates a shaft current. The cumulative effect causes electrical corrosion; therefore, in this study, an electrical corrosion protection device for the rotating power supply shaft was developed. It detected current and potential difference and established a feedback system on the rotating shaft. It also energized the rotating shaft using an external power supply to eliminate the potential difference on the shaft and reduce electrical corrosion. The result was prolonged motor life and improved stability, operating efficiency, and operability of related equipment. In this study, a rotating-shaft test rig was set up, and a constant current was applied to simulate the potential difference and verify the performance of the anti-corrosion device. Gradually, the design scheme was optimized; the potential difference on the rotating shaft was accurately quantified; and the goal of controlling the potential difference within 2 mV was achieved. Finally, the electrical corrosion protection device was applied to the rotating shaft of a merchant ship, and the current and potential difference on the rotating shaft were monitored for 30 days. The results showed that the device had excellent performance in reducing the potential difference on the rotating shaft and preventing electrical corrosion.