Gianluca Botticelli

Dr. Gianluca Botticelli

Università degli Studi dell'Aquila

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2022 in Coatings
Verified
Journal Article
Open access
PDF file
Giovanni FalisiGiovanni Falisi
Giovanni Falisi
Giordano FoffoGiordano Foffo
Giordano Foffo
MSMarco Severino
Marco Severino
CPCarlo Di Paolo
Carlo Di Paolo
SBSerena Bianchi
Serena Bianchi
GBGianluca Botticelli
Gianluca Botticelli
The preparation of the implant site in guided surgery procedure takes place without irrigation, which could lead to increased friction of the drills with the formation and release of debris or metal particles. The presence of metal particles in the peri-implant tissue could represent a trigger for macrophage activity, bone resorption processes, and consequent implant loss. According to the guided surgical protocol, the study aimed to evaluate the presence of metal particles deposited during implant site preparation. Twenty-five adult porcine ribs from the same adult individual were chosen due to their trabecular bone structure, similar to facial bones. The samples were all 8 cm (length) × 3 cm (depth) × 2 cm (width) and were further subdivided to obtain 50 elements of 4 cm × 3 cm × 2 cm. Plexiglass was used to create structures such as surgical guides so that their function could be mimicked, and the guided implant site preparation sequence could be performed with them. The drill kit used in this study is a guided surgery drill kit characterized by high wear resistance, high yield strength, and good corrosion resistance. This same kit was used 50 times in this way to prepare 50 different implant sites and evaluated at different edges and number of preparation (T0-neutral edge, T1-1 full preparation, T2-10, T3-20, T4-30, T5-40, and T6-50) by SEM-EDX to assess the presence of any metal deposition. The presence of metal residues in the implant site increased according to the cycles of use of the drills. We have observed that in the first three groups, there is no presence of metals. This is evident in groups T3 and T4. Finally, the presence of metal residues becomes significant in the study’s last two groups of samples. The study highlighted how the lack of irrigation in the work site leads the deposition of metal particles and in addition to a reduction in the efficiency of the drills, resulting in less precise cutting, altering the shape of the prepared site, and, lastly, reducing the primary stability of the implants.

6 February 2021 in Healthcare
Verified
Journal Article
Open access
PDF file
Giovanni FalisiGiovanni Falisi
Giovanni Falisi
CPCarlo Di Paolo
Carlo Di Paolo
CRClaudio Rastelli
Claudio Rastelli
CFCarlo Franceschini
Carlo Franceschini
SRsofia rastelli
sofia rastelli
GBGianluca Botticelli
Gianluca Botticelli
This study aimed to evaluate the effectiveness of using ultrashort implants in the rehabilitation of jaws of fragile patients. The aim of the study was to retrospectively evaluate the survival rate of full-arch prosthetic rehabilitation on ultrashort implants, length 4 mm, 4 mm in diameter in the premolar and canine area and 4.5 mm in diameter in the molar area, with the insertion torque of 60 Nw and immediate loading. Nineteen patients were evaluated for 3 years clinically and radiographically. The significant majority of the patients at the 3 year follow-up (T4) presented a stable and functional implant-supported prothesis, and the survival rate of the implants was 85%, with a loss of 16 implants on 114 implants. The combination of the innovative implant surfaces and the correct project of the prostheses, with the related implant connection, determined a different timing in the therapy, allowing to obtain an immediate loading, which is currently demanded by patients. This and recent reports on short and ultrashort implant usage in atrophic jaws offer a good solution in critical cases. In conclusion, within the limits of the study, the full-arch rehabilitation with immediate loading on ultrashort implants showed good results with few postoperative complications and related low biological cost.