Guanjun Zhang

Prof. Guanjun Zhang


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Waste Management
Verified
Journal Article
Closed access
BSBaipeng Song
Baipeng Song
MZMeng-Yao Zhang
Meng-Yao Zhang
YFYue Fan
Yue Fan
LJLing Jiang
Ling Jiang
JKJun Kang
Jun Kang
XZXiang Zhou
Xiang Zhou

12 November 2015 in Wound Repair and Regeneration
Verified
Journal Article
Closed access
PDF file
GXGui‐Min Xu
Gui‐Min Xu
XSxingmin shi
xingmin shi
JCJing‐Fen Cai
Jing‐Fen Cai
SCSi‐Le Chen
Si‐Le Chen
PLPing Li
Ping Li
Guanjun ZhangGuanjun Zhang
Guanjun Zhang

28 August 2018 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
JXJianyi Xue
Jianyi Xue
HWHan Wang
Han Wang
JCJunhong Chen
Junhong Chen
KLKefeng Li
Kefeng Li
YLYanqin Liu
Yanqin Liu
Guanjun ZhangGuanjun Zhang
Guanjun Zhang
The accumulated charges on the insulator surface become a key factor to incur surface flashover. The charge accumulation process is closely related to the surface condition. This research investigates the effects of surface roughness on surface charge accumulation behavior and surface flashover performance of alumina-filled epoxy resin spacers in SF6/N2 mixtures under DC voltage. The insulator is prepared with only half surface subjected to rough treatment. The accumulated charges are distributed in two regions. Considerable homo-charges are located near the high voltage (HV) electrode and few hetero-charges are near the grounded (GND) electrode (region I). These charges are injected by electrodes. The bipolar charges between HV and GND electrodes (region II) originate from gas ionization. Surface rough treatment can suppress surface charge accumulation and improve surface insulation strength. When increasing surface roughness, surface charge declines first slowly (stage I) and then rapidly (stage II), which coincides with the two stages of surface flashover voltage increment. Surface charge declination at stage I is mainly due to the increase in surface conductivity, while at stage II, the introduced deep traps also play a role. Surface flashover voltage increment at stage I is mainly due to the extended creepage distance, while at stage II, the declination of surface charge also plays a role. Besides, the block of electron avalanche development by the roughed surface is also responsible for the increase in surface flashover voltage at these two stages.

26 July 2019 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
PDF file
JXJianyi Xue
Jianyi Xue
JCJun-Hong Chen
Jun-Hong Chen
JDJun-Hao Dong
Jun-Hao Dong
HWHan Wang
Han Wang
Wendong LiWendong Li
Wendong Li
Guanjun ZhangGuanjun Zhang
Guanjun Zhang
Surface charge accumulation on insulators becomes an important bottleneck to restrain the development of a DC energy transmission system. This study investigates the effects of SiC/epoxy coating on surface charge behaviors and flashover performance of alumina/epoxy spacers. A nonlinear conductive coating consisting of different contents of SiC fillers and epoxy matrix was fabricated and sprayed on only half surface of the spacers. The dependence of surface charges on the contents of SiC fillers is characterized by three stages. Surface charge accumulation is aggravated at deterioration stage, then almost unaltered at balance stage and inhibited at suppression stage. These three stages are determined by the competition between the increased surface trap density from interface region and the improved surface conductivity from SiC fillers. The variation trend of flashover in air and SF 6 /N 2 mixtures is distinguished by three stages as well. Flashover voltage decreases at descent stage where deficient contents of SiC fillers are appended and then goes up at improved stage with moderate supply of SiC fillers. Finally, it ends up with drastically collapse at degenerated stage when affluent SiC fillers are brought in. The theoretical analysis is proposed based on surface trap distribution and conductivity measurement results to reveal the regulation mechanism of SiC/epoxy coating on surface charge behavior and flashover performance.

31 March 2021 in High Voltage
Verified
Journal Article
Open access
PDF file
MZMing-Xiao Zhu
Ming-Xiao Zhu
JXJianyi Xue
Jianyi Xue
YWYanhui Wei
Yanhui Wei
Guochang LiGuochang Li
Guochang Li
Guanjun ZhangGuanjun Zhang
Guanjun Zhang
Interfaces between different materials, for instance, electrode–dielectrics and vacuum/air/SF 6 ‐insulators and oilpaper, are universal in high‐voltage insulation systems. Targeted tailoring of the interfacial properties, e.g. chemical structures, micro‐/nanoscale morphology, the charge injection barrier, trap states, and surface conductivity, is thought to be an effective approach to improve insulation properties such as breakdown and flashover strength, corona/tracking resistance, and wettability. In this article, the authors review recent progress in interface tailoring methods and their application to improve various insulation properties. The potential application scenarios of interface tailoring in different facilities are first summarised, and the desired insulation properties of various applications are highlighted. Interface tailoring methods are classified as physical/chemical surface modification and surface coating (inorganic, organic and composite), and the features of different techniques are described in detail. The structure–property relationships between interfacial states and various microscopic parameters such as charge injection barrier, trap distribution and surface conductivity are discussed together with the tailoring mechanisms for different insulation properties. Finally, the future development prospects of interface tailoring methods and their applications, e.g. multifunctional coating and stimuli–response smart coating, are presented.

31 December 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
HMHaibao Mu
Haibao Mu
HZHao-Tian Zhang
Hao-Tian Zhang
XZXing-Yu Zou
Xing-Yu Zou
DZDa-Ning Zhang
Da-Ning Zhang
XLXu Lu
Xu Lu
Guanjun ZhangGuanjun Zhang
Guanjun Zhang
Cable fault location is generally much more difficult if cable defect has not reached the level of serious breakdown. Traditional methods such as time domain reflectometry (TDR) and partial discharge detection cannot solve this problem well due to their low sensitivity. This paper proposes a new non-destructive detection method based on the impedance spectroscopy (IS), which can effectively locate soft faults in the cable. In this paper, a numerical model for cable with distributed parameters is established firstly. Based on this model, cable faults are extracted from the imaginary part of impedance spectrum with Discrete Fourier Transform (DFT). The Chebyshev window is introduced to suppress interference and enhance signal-to-noise ratio, which improves the sensitivity and accuracy of fault location significantly. Experiments and simulations show that this method can well locate multi-segment defects in cables with good accuracy. The window function successfully amplifies the normalized amplitude of faults and improves the positioning accuracy. Compared with other method, this method reduces distortion points effectively. The fault location error is within 0.53%, which has great potential for field application.