Guy Ayissi Eyebe

Mr. Guy Ayissi Eyebe

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 April 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
AAAbdelhak Hamid Allah
Abdelhak Hamid Allah
GEGuy Ayissi Eyebe
Guy Ayissi Eyebe
FDFrederic Domingue
Frederic Domingue
This paper proposes a fully 3D-printed electromagnetic (EM) microfluidic sensor using rectangular substrate integrated waveguide (SIW) for liquid complex permittivity characterization. The proposed microfluidic sensor is fabricated with a novel additive manufacturing process in which dielectric and conductive inks are simultaneously 3D-printed, allowing high print quality, rapid prototyping, and arbitrary geometry. The fabrication process removes the need for post-printing sintering and cleaning steps that require harmful chemicals. The sensor structure is composed of upper and lower metal plates and a series of cylindrical metal side vias. Since the electric field is high at the center of the SIW cavity in $\textit {TE}_{101}$ mode, a cylindrical dielectric sample container in the form of a microwell is built into the center of the SIW cavity to maximize the perturbation of the liquid under test (LUT). The application of LUT samples to the microwell results in a change in the resonance frequency and peak attenuation from which the LUT sample is characterized. Ethanol-water mixtures are used as LUTs for validation. The proposed sensor has been verified numerically and experimentally, reducing the resonant frequency from 3.750 GHz to 3.862 GHz by increasing the ethanol volume fraction from 0% to 100%. The sensor showed good sensitivity of 0.345% and a stable frequency change was observed over five measurement repetitions. To the best of our knowledge, this article presents the first fully 3D-printed SIW microfluidic sensor and demonstrates its ability to detect and characterize the liquid complex permittivity.

1 July 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
GEGuy Ayissi Eyebe
Guy Ayissi Eyebe
BBBenoît Bideau
Benoît Bideau
ELEric Loranger
Eric Loranger
FDFrédéric Domingue
Frédéric Domingue

1 March 2019 in IEEE Microwave and Wireless Components Letters
Verified
Journal Article
Closed access
GEGuy Ayissi Eyebe
Guy Ayissi Eyebe
NSNossikpendou Sama
Nossikpendou Sama
NBNaimi Boubekeur
Naimi Boubekeur
FDFrederic Domingue
Frederic Domingue

11 September 2018 in IEEE Sensors Letters
Verified
Journal Article
Closed access
GEGuy Ayissi Eyebe
Guy Ayissi Eyebe
BBBenoit Bideau
Benoit Bideau
ELEric Loranger
Eric Loranger
NBNaimi Boubekeur
Naimi Boubekeur
FDFrederic Domingue
Frederic Domingue
Humidity-sensitive dielectric sheets combine easy integration of humidity sensing ability and high sensitivity performance through microwave technologies. However, only a few materials have been investigated so far. This article introduces TEMPO oxidized nanocellulose (TOCN) composite sheets with polyvinyl alcohol (PVOH) as a sensitive material with low ecological footprint for microwave humidity sensing. Preparation and physical characterization of these novel sensitive materials are realized. The humidity sensing performances are studied with a CPW-based serial resonator where the sensitive sheets are deposited. Experimental results validate the sensitivity of TOCN/PVOH sheets both in reflection and transmission. Dynamic range, sensitivity, and the robustness of microwave parameters over the humidity measurement range are analyzed. The best results are reached with the sample with only 4 wt% of PVOH: 1.85 MHz/%RH in the 55–100%RH for the frequency response and 0.46°/%RH in 70–100%RH range for the phase response.

9 April 2025 in Sensors
Verified
Journal Article
Open access
PDF file
AAAbdelhak Hamid Allah
Abdelhak Hamid Allah
GEGuy Ayissi Eyebe
Guy Ayissi Eyebe
FDFrédéric Domingue
Frédéric Domingue
This paper presents a fully 3D-printed microfluidic microwave sensor based on substrate-integrated waveguide (SIW) technology for detecting glucose levels in liquid, aimed at monitoring diabetic patients. The sensor’s design features a circular SIW cavity with an integrated sample holder placed in the cavity’s center, maximizing the electric field disturbance from the liquid under test (LUT). Operating in the TM010 mode at a resonance frequency around 5.740 GHz, the sensor detects glucose concentrations by measuring resonance frequency shifts in the S11 reflection response across glucose levels. A conductive sheath partially covers the sample holder to enhance sensitivity and improve the limit of detection (LOD) by increasing field penetration into the LUT. Fabricated using an additive manufacturing electronics (AMEs) method, the sensor is produced in a single pass without post-processing. The experimental validation confirms its high sensitivity of 1.218 MHz/(mg/dL) and a low limit of detection of 0.774 mg/dL in the glucose concentration range (10–200 mg/dL), reflecting typical Type 2 diabetes levels. The key advantages of the sensor include its compactness, enhanced sensitivity and limit of detection, innovative manufacturing, and cost-effectiveness, supporting its potential as a non-invasive glucose monitoring tool. This study establishes a proof of concept for the in vitro measurement of glucose, demonstrating the sensor’s ability to provide accurate and reliable results in a controlled environment.

1 May 2019 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
GEGuy Ayissi Eyebe
Guy Ayissi Eyebe
ARAina H. Rasolomboahanginjatovo
Aina H. Rasolomboahanginjatovo
BBBenoit Bideau
Benoit Bideau
FDFrédéric Domingue
Frédéric Domingue