Gwi-Un Oh

Mr. Gwi-Un Oh

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2025 in Energies
Verified
Journal Article
Open access
PDF file
GOGwi-Un Oh
Gwi-Un Oh
SeungTaik KimSeungTaik Kim
SeungTaik Kim
JKJong-Sun Ko
Jong-Sun Ko
This study introduces a sensorless fault diagnosis method for efficiently detecting bearing faults in induction motors. The proposed method eliminates the need for torque sensors, frequency sensors, thermal cameras, or real-time Fast Fourier Transform (FFT) tools. Induction motors are commonly utilized in a variety of industrial applications, including fans, pumps, and home appliances, due to their straightforward construction, affordability, and robust reliability. Traditional bearing fault diagnosis methods often rely on additional hardware such as vibration or thermal sensors. Additionally, approaches employing Artificial Intelligence (AI) and real-time FFT processing require advanced and expensive hardware capabilities. However, many V/f control systems are primarily intended for cost-effective and simple implementations, making resource-intensive approaches undesirable. Therefore, such methods present limitations for these use cases. To address these challenges, this paper presents a sensorless detection technique that estimates torque via a flux observer, removing the dependence on external sensors. The estimated torque is processed using an offline FFT to identify amplitude changes within bearing fault frequency bands. Here, the FFT-based frequency analysis is performed offline and is used to design a targeted band-pass filter (BPF). The torque signal, after passing through the BPF, undergoes a straightforward threshold-based logic to assess the existence of faults. Compared to AI- or data-driven approaches, the proposed method provides a lightweight, interpretable, and sensorless solution without the need for additional training or high-end processors. Despite its straightforward approach, the technique achieves effective detection of bearing faults across various components and speeds, making it ideal for embedded and economically constrained motor applications.

8 August 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
GOGwi-Un Oh
Gwi-Un Oh
창홍창완 홍
창완 홍
JKJong-Sun Ko
Jong-Sun Ko
In this study, a sensorless speed control method is proposed to enhance the speed control performance under load variations by utilizing a discrete–time flux observer in a V/f control environment. Due to their simple structure, low cost, and high reliability, induction motors are widely used in various fields, such as fans, pumps, and home appliances. Among the control methods for induction motors, V/f control operates as an open-loop system, without using speed sensors. It is mainly applied in industrial environments where fast dynamic performance is not required, due to its simple implementation and low cost. However, in cases of load variations or low-speed operation, it suffers from performance degradation and control limitations due to flux variations. To overcome these issues, this paper proposes a method that uses a discrete–time flux observer to estimate the stator flux. We calculate the rotor speed based on the estimated flux, and then improve V/f control performance by adding a compensation signal to the reference frequency, which signal is generated through a PI controller based on the difference between the estimated rotor speed and the reference speed. The proposed method is validated through MATLAB/Simulink-based simulations and experiments using a 5.5 kW induction motor M−G set, confirming that compared to conventional V/f control, the speed maintenance capability and overall robustness against load variations are enhanced. This study presents a practical solution to effectively improve the performance of existing V/f control systems without adding external sensors.

16 September 2025 in Energies
Verified
Journal Article
Open access
PDF file
GOGwi-Un Oh
Gwi-Un Oh
창홍창완 홍
창완 홍
JKJong-Sun Ko
Jong-Sun Ko
In this study, a sensorless speed control method is proposed to enhance the speed control performance under load variations by utilizing a discrete-time flux observer in a V/f control environment. Due to their simple structure, low cost, and high reliability, induction motors are widely used in various fields, such as fans, pumps, and home appliances. Among the control methods for induction motors, V/f control operates as an open-loop system, without using speed sensors. It is mainly applied in industrial environments where fast dynamic performance is not required, due to its simple implementation and low cost. However, in cases of load variations or low-speed operation, it suffers from performance degradation and control limitations due to flux variations. To overcome these issues, this paper proposes a method that uses a discrete-time flux observer to estimate the stator flux. We calculate the rotor speed based on the estimated flux, and then improve V/f control performance by adding a compensation signal to the reference frequency, which signal is generated through a PI controller based on the difference between the estimated rotor speed and the reference speed. The proposed method is validated through MATLAB/Simulink-based simulations and experiments using a 5.5 kW induction motor M−G set, confirming that compared to conventional V/f control, the speed maintenance capability and overall robustness against load variations are enhanced. This study presents a practical solution to effectively improve the performance of existing V/f control systems without adding external sensors.