12 April 2024 in Energies
Verified
Journal Article
Open access
PDF file
Dong-Eon KimDong-Eon Kim
Dong-Eon Kim
Gyeong-Yeol LeeGyeong-Yeol Lee
Gyeong-Yeol Lee
GKGYUNG-SUK KIL
GYUNG-SUK KIL
SKSungwook Kim
Sungwook Kim
Voltage and current measurements in high-voltage substations are fundamental for stable operation. Conventional instrument transformers (ITs) face challenges in gas-insulated switchgears (GISs), such as size, weight, accuracy limitations, and behavioral instability at abnormal voltages and currents. Non-conventional instrument transformers (NCITs) have emerged to address these issues, complying with International Electrotechnical Commission (IEC) standards and providing millivolt-level signals, enabling downsizing of GIS bays. The transition to digital substations, as mandated by IEC 61850-9-2, requires a shift from the conventional 110 V/5 A outputs to levels ranging from millivolts to volts. Electronic instrument transformers (EITs), compliant with the IEC 60044-7 and 8 standards, offer alternatives to conventional ITs with smaller sizes and wider frequency ranges. However, issues remain with EITs, including limited adoption, the necessity of separate power sources, and susceptibility to electromagnetic interference. Recent standards, transitioning to IEC 61869, focus on low-power instrument transformers (LPITs). Low-power voltage transformers (LPVTs) and low-power current transformers (LPCTs), designed with passive components, present potential solutions by directly connecting to merging units (MUs) for digital signal transmission. This review outlines the current status of various IT standards, covering conventional ITs, EITs based on IEC 60044-7 and 8, and LPITs based on IEC 61869-10 and 11. Advancements in sensor technology relevant to these standards are also explored. The paper provides insights into the evolving landscape of instrument transformers, addressing challenges and offering potential pathways for future developments in digital substations.

9 May 2025 in Electronics
Verified
Journal Article
Open access
PDF file
Gyeong-Yeol LeeGyeong-Yeol Lee
Gyeong-Yeol Lee
GKGYUNG-SUK KIL
GYUNG-SUK KIL
Fault diagnosis based on the partial discharge (PD) recognition has been widely applied on a gas-insulated line breaker (GILB) and gas-insulated switchgear (GIS) as a reliable online condition monitoring method. This paper dealt with insulation defect diagnosis based on a Random Forest (RF) algorithm with an optimized feature selection method. Four different types of insulation defect models, such as the free-moving particle (FMP) defect, the protrusion-on-conductor (POC) defect, the protrusion-on-enclosure (POE) defect, and the delamination defect, were prepared to simulate representative PD single pulses and PRPD patterns generated from the GILB. The PD signals generated from defect models were detected using the PRPD sensor which can detect phase-synchronized PD signals with the applied high-voltage (HV) signals without the need for additional equipment. Various statistical PD features were extracted from PD single pulses and PRPD patterns according to four kinds of PD defect models, and optimized features were selected with respect to variance importance analysis. Two kinds of PD datasets were established using all statistical features and top-ranked features. From the experimental results, the RF algorithm achieved accuracy rates exceeding 92%, and the PD datasets using only half of the statistical PD features could reduce the computational times while maintaining the accuracy rates.

15 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Gyeong-Yeol LeeGyeong-Yeol Lee
Gyeong-Yeol Lee
NKNam-Hoon Kim
Nam-Hoon Kim
Dong-Eon KimDong-Eon Kim
Dong-Eon Kim
GKGYUNG-SUK KIL
GYUNG-SUK KIL
SKSungwook Kim
Sungwook Kim
This paper proposes a novel phase-resolved partial discharge (PRPD) sensor embedded in a MV-class bushing for high-accuracy insulation analysis. The design, fabrication, and evaluation of a PRPD sensor embedded in a MV-class bushing aimed to achieve the detection of partial discharge (PD) pulses that are phase-synchronized with the applied primary HV signal. A prototype PRPD sensor was composed of a flexible printed circuit board (PCB) with dual-sensing electrodes, utilizing a capacitive voltage divider (CVD) for voltage measurement, the D-dot principle for PD detection, and a signal transducer with passive elements. A PD simulator was prepared to emulate typical PD defects, i.e., a metal protrusion. The voltage measurement precision of the prototype PRPD sensor was satisfied with the accuracy class of 0.2 specified in IEC 61869-11, as the maximum corrected voltage error ratios and corrected phase errors in 80%, 100%, and 120% of the rated voltage (13.2 kilovolts (kV)) were less than 0.2% and 10 min, respectively. In addition, the prototype PRPD sensor had good linearity and high sensitivity for PD detection compared with a conventional electrical detection method. According to performance evaluation tests, the prototype PRPD sensor embedded in the MV-class bushing can measure PRPD patterns phase-synchronized with the primary voltage without any additional synchronization equipment or system. Therefore, the prototype PRPD sensor holds potential as a substitute for conventional commercial PD sensors. Consequently, this advancement could lead to the enhancement of power system monitoring and maintenance, contributing to the digitalization and minimization of power apparatus.

1 December 2025 in Journal of Electrical Engineering
Verified
Journal Article
Open access
PDF file
Gyeong-Yeol LeeGyeong-Yeol Lee
Gyeong-Yeol Lee
GKGYUNG-SUK KIL
GYUNG-SUK KIL
SKSungwook Kim
Sungwook Kim
Cast-resin transformers have been widely installed in a power system due to excellent arc-extinguishing characteristics, easy installation, and low expense of maintenance. From the perspective of condition monitoring, identification and classification techniques of internal defects based on partial discharge (PD) measurements are getting more important. This paper studies PD defect classification using two kinds of machine learning (ML) algorithms, random forest (RF) and artificial neural network (ANN) models. Four typical PD defect models were designed: metal protrusion, a particle on insulator, delamination, and a void. PD single pulses and phase-resolved partial discharge (PRPD) patterns at each partial discharge inception voltage (PDIV) were measured by the printed circuit board (PCB) based Rogowski-type PD sensor. Various kinds of PD features were extracted from each PD single pulse and PRPD pattern. From the experimental results, the two different ML algorithms, used in this paper, could classify the PD defects with over 90%, and the PD classification rate using RF model was slightly higher than that of the ANN model.

31 March 2021 in Journal of the Korean society for railway
Verified
Journal Article
Closed access
Gyeong-Yeol LeeGyeong-Yeol Lee
Gyeong-Yeol Lee
GKGyung-Suk Kil
Gyung-Suk Kil
SKSung-Wook Kim
Sung-Wook Kim
본 논문에서는 진공차단기(VCB)의 핵심 부품이자, 개폐 시 발생된 아크를 소호하는 진공 인터럽터 (VI)에 내부 결함이 생길 경우에 발생되는 부분방전(PD)의 특성에 대해 다루었다. PD를 발생시키기 위한 결함 모의에는 상용 VI와 그 접점으로 만든 전극계를 사용하였다. 내부 결함의 종류는 VI의 일반적 고장원인인 진공누설 결함, 불완전한 개방결함으로 선정하였다. 방전개시전압(DIV), 겉보기전하량, 펄스 수, 극성비, PRPD의 측면에서 결함 별 PD 특성을 정상조건과 비교했다. 각 결함에서의 DIV는 정상 상태에서 보다 2kV 씩 감소되었으며 복합 결함의 DIV는 19kV이었다. 그리고 최대 인가전압에서 진공누설 결함에서의 겉보기 전하량은 불완전한 개방 결함에서 보다 8.3% 높았다. 또한, DIV에서 검출된 각 결함 별 부극성 펄스의 비율은 정상상태에서 보다 3~5% 높게 검출되었으며 복합결함에서의 부극성비율은 54%였다. 그러므로 본 논문의 결과는 진공 인터럽터의 온라인 절연 진단에 활용할 수 있을 것으로 사료된다.

13 November 2022
Verified
Conference Paper
Closed access
SKSung-Wook Kim
Sung-Wook Kim
NKNam-Hoon Kim
Nam-Hoon Kim
Gyeong-Yeol LeeGyeong-Yeol Lee
Gyeong-Yeol Lee
GKGyung-Suk Kil
Gyung-Suk Kil
Power transformers are widely applied to power systems and are one of the important power equipment to supply electricity necessary to users. One of them, the installation of molded power transformers has been increased in the distribution system due to low maintenance cost and it is not significantly affected by environmental factors such as chemicals, dust, and moisture. However, when it has some defects during the manufacturing process or insulation deterioration during operation, a partial discharge (PD) occurs, and it leads to insulation breakdown. In this paper, different types of Rogowski coil sensors (RCSs) were designed to compare the sensitivity for PD measurement to replace expensive commercial sensors such as an acoustic emission (AE) sensor and an ultra-high frequency (UHF) sensor. The planar and thin structures on a printed circuit board (PCB) were applied to the RCSs. A PD electrode system was fabricated to simulate a PD signal produced in a molded power transformer. From the experimental results, it was confirmed the RCS type with good linearity and high sensitivity, and it is expected that the proposed low-cost RCS is used for PD measurement.