Hironobu Koseki

Prof. Hironobu Koseki

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2014 in BMC Microbiology
Verified
Journal Article
Open access
PDF file
IYItaru Yoda
Itaru Yoda
HKHironobu Koseki
Hironobu Koseki
MTMasato Tomita
Masato Tomita
TSTakayuki Shida
Takayuki Shida
HHHidehiko Horiuchi
Hidehiko Horiuchi
MOMakoto Osaki
Makoto Osaki
Implant-related infections are caused by adhesion of bacteria to the surface of biomaterials. In this in vitro research, we evaluated the ability of Staphylococcus epidermidis (ATCC35984) to adhere to the surface of solid biomaterials at different levels of roughness below 30 nm Ra and investigated the minimum level of roughness required to promote bacterial adhesion on five kinds of biomaterials: oxidized zirconium-niobium alloy (Oxinium), cobalt-chromium-molybdenum alloy (Co-Cr-Mo), titanium alloy (Ti-6Al-4 V), commercially pure titanium (Cp-Ti) and stainless steel (SUS316L), samples of which were categorized into a fine group and a coarse group according to surface roughness. The test specimens were physically analyzed and the viable bacterial density of the adhered bacteria was quantitatively determined (n = 20). The amount of bacteria that adhered to the biomaterials in the coarse group was higher than those in the fine group. Oxinium, Ti-6Al-4 V and SUS316L in particular demonstrated statistically significant differences between the two groups (P < 0.05). Of the materials, the Co-Cr-Mo specimens exhibited significantly lower amounts of adhered bacteria than the Ti-6Al-4 V, Cp-Ti and SUS316L specimens in the fine group. Similarly, the Co-Cr-Mo specimens in the coarse group exhibited significantly lower values than the other four materials. These results suggest that minimum level of roughness affecting initial bacterial adherence activity differs according to the type of biomaterial used, and that even a surface roughness of below 30 nm Ra in Oxinium, Ti-6Al-4 V and SUS316L can promote bacterial adhesion. Relative hydrophobic Co-Cr-Mo surfaces were less susceptible to bacterial adherence.

9 October 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HKHironobu Koseki
Hironobu Koseki
AYAkihiko Yonekura
Akihiko Yonekura
TSTakayuki Shida
Takayuki Shida
IYItaru Yoda
Itaru Yoda
HHHidehiko Horiuchi
Hidehiko Horiuchi
MTMasato Tomita
Masato Tomita
Biofilms forming on the surface of biomaterials can cause intractable implant-related infections. Bacterial adherence and early biofilm formation are influenced by the type of biomaterial used and the physical characteristics of implant surface. In this in vitro research, we evaluated the ability of Staphylococcus epidermidis, the main pathogen in implant-related infections, to form biofilms on the surface of the solid orthopaedic biomaterials, oxidized zirconium-niobium alloy, cobalt-chromium-molybdenum alloy (Co-Cr-Mo), titanium alloy (Ti-6Al-4V), commercially pure titanium (cp-Ti) and stainless steel. A bacterial suspension of Staphylococcus epidermidis strain RP62A (ATCC35984) was added to the surface of specimens and incubated. The stained biofilms were imaged with a digital optical microscope and the biofilm coverage rate (BCR) was calculated. The total amount of biofilm was determined with the crystal violet assay and the number of viable cells in the biofilm was counted using the plate count method. The BCR of all the biomaterials rose in proportion to culture duration. After culturing for 2–4 hours, the BCR was similar for all materials. However, after culturing for 6 hours, the BCR for Co-Cr-Mo alloy was significantly lower than for Ti-6Al-4V, cp-Ti and stainless steel (P0.05). These results suggest that surface properties, such as hydrophobicity or the low surface free energy of Co-Cr-Mo, may have some influence in inhibiting or delaying the two-dimensional expansion of biofilm on surfaces with a similar degree of smoothness.

6 July 2017 in BMC Surgery
Verified
Journal Article
Open access
PDF file
CNChieko Noguchi
Chieko Noguchi
HKHironobu Koseki
Hironobu Koseki
HHHidehiko Horiuchi
Hidehiko Horiuchi
AYAkihiko Yonekura
Akihiko Yonekura
MTMasato Tomita
Masato Tomita
MOMakoto Osaki
Makoto Osaki
Surgical-site infections due to intraoperative contamination are chiefly ascribable to airborne particles carrying microorganisms. The purpose of this study is to identify the actions that increase the number of airborne particles in the operating room. Two surgeons and two surgical nurses performed three patterns of physical movements to mimic intraoperative actions, such as preparing the instrument table, gowning and donning/doffing gloves, and preparing for total knee arthroplasty. The generation and behavior of airborne particles were filmed using a fine particle visualization system, and the number of airborne particles in 2.83 m3 of air was counted using a laser particle counter. Each action was repeated five times, and the particle measurements were evaluated through one-way analysis of variance multiple comparison tests followed by Tukey–Kramer and Bonferroni–Dunn multiple comparison tests for post hoc analysis. Statistical significance was defined as a P value ≤ .01. A large number of airborne particles were observed while unfolding the surgical gown, removing gloves, and putting the arms through the sleeves of the gown. Although numerous airborne particles were observed while applying the stockinet and putting on large drapes for preparation of total knee arthroplasty, fewer particles (0.3–2.0 μm in size) were detected at the level of the operating table under laminar airflow compared to actions performed in a non-ventilated preoperative room (P < .01). The results of this study suggest that surgical staff should avoid unnecessary actions that produce a large number of airborne particles near a sterile area and that laminar airflow has the potential to reduce the incidence of bacterial contamination.

4 September 2019 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
THTakashi Higuchi
Takashi Higuchi
HKHironobu Koseki
Hironobu Koseki
AYAkihiko Yonekura
Akihiko Yonekura
KCKo Chiba
Ko Chiba
YNYusuke Nakazoe
Yusuke Nakazoe
MOMakoto Osaki
Makoto Osaki
The purpose of this study was to compare radiological features between high tibial osteotomy (HTO) and tibial condylar valgus osteotomy (TCVO), in order to define the radiological indication criteria for TCVO. Thirty-two cases involving 35 knees that had undergone HTO and the same number that had undergone TCVO for knee osteoarthritis were retrospectively evaluated. Characteristics of both groups did not differ significantly. Lower limb alignment, bone morphology, joint congruity, and joint instability were measured in standing full-length leg and knee radiographs obtained before and after surgery. Radiological features in the TCVO group included greater frequencies of advanced knee OA grade, varus lower limb malalignment, depression of the medial tibial plateau, and varus-valgus joint instability compared to the HTO group before surgery. However, tibial morphology, alignment of the lower limb, and joint instability improved to comparable levels after surgery in both groups. TCVO appears preferable in cases with advanced knee OA, destroyed or inclined medial tibial plateau, widened and subluxated lateral joint, and high varus-valgus joint instability.

1 October 2013 in International Journal of Nanomedicine
Verified
Journal Article
Open access
HKHironobu Koseki
Hironobu Koseki
TSTakayuki Shida
Takayuki Shida
IYItaru Yoda
Itaru Yoda
HHHidehiko Horiuchi
Hidehiko Horiuchi
HSHideyuki Sakoda
Hideyuki Sakoda
MOMakoto Osaki
Makoto Osaki
Peer reviewed article authored by (Shida T, Koseki H, Yoda I, Horiuchi H, Sakoda H, Osaki M). Read article or submit your manuscript for publishing.

10 July 2021 in Archives of Osteoporosis
Verified
Journal Article
Open access
PDF file
HKHironobu Koseki
Hironobu Koseki
SSShinya Sunagawa
Shinya Sunagawa
CNChieko Noguchi
Chieko Noguchi
AYAkihiko Yonekura
Akihiko Yonekura
UMUmi Matsumura
Umi Matsumura
MOMakoto Osaki
Makoto Osaki
Summary: The annual incidence of new hip fractures increased from 2005 to 2014 in Nagasaki and females were much more affected. High-risk factors were identified as age ≥ 80 years, winter, indoors, living room, Monday, and early morning. Seven days after admission, most patients remained hospitalized and had been treated surgically. Introduction: Hip fractures are major osteoporotic fractures that reduce quality of life. In Japan, the incidence of hip fractures increased steadily from 1986 to 2014 and the number of hip fractures could be 7.3–21.3 million by 2050. This study aimed to determine the incidence of hip fractures from 2005 to 2014 in Nagasaki Prefecture and to analyze the characteristics of and risk factors for hip fracture. Methods: Hip fractures that occurred in Nagasaki Prefecture between 2005 and 2014 were analyzed using emergency transportation records. Fracture type, age, sex, location in which fracture occurred, and risk factors for hip fracture were clarified. Results: The total number of new hip fractures among individuals ≥ 35 years old was 17,395 (mean age, 82.6 years old) and the annual incidence per 100,000 population increased from 147.9 in 2005 to 235.0 in 2014. Females (79.6%) were much more commonly affected than males (20.4%) and cervical fractures were more common than trochanteric fractures in all age groups. Hip fracture tended to be associated with age ≥ 80 years, winter rather than summer, indoors rather than outdoors, and living room rather than the bathroom or toilet. Other high-risk factors were Monday as day of the week, and early morning as the time of day. Seven days after admission, 97.3% of patients were hospitalized and 78.1% of hip fractures had been treated surgically. Conclusion: Information on actual situations and valid preventive measures relevant to hip fracture are urgently needed.