Since the cell was discovered by humans, it has been an important research subject for researchers. The mechanical response of cells to external stimuli and the biomechanical response inside cells are of great significance for maintaining the life activities of cells. These biomechanical behaviors have wide applications in the fields of disease research and micromanipulation. In order to study the mechanical behavior of single cells, various cell mechanics models have been proposed. In addition, the measurement technologies of single cells have been greatly developed. These models, combined with experimental techniques, can effectively explain the biomechanical behavior and reaction mechanism of cells. In this review, we first introduce the basic concept and biomechanical background of cells, then summarize the research progress of internal force models and experimental techniques in the field of cell mechanics and discuss the latest mechanical models and experimental methods. We summarize the application directions of cell mechanics and put forward the future perspectives of a cell mechanics model.
An electrothermal microgripper is an important actuator in microelectromechanical and micro-operating systems, and its temperature field analysis is the core problem in research and design. Because of the small size of an electrothermal microgripper, its microscale heat transfer characteristics are different from those of the macrostate. At present, only a few studies on the heat transfer scale effect in electrothermal microgrippers have been conducted, and the heat transfer analysis method under the macrostate is often used directly. The temperature field analysed and simulated is different from the actual situation. In the present study, the heat transfer mechanism of an electrothermal microgripper in the microscale was analysed. The temperature field of a series of microscale heating devices was measured using microthermal imaging equipment, and the heat transfer parameters of the microscale were fitted. Results show that the natural convective heat transfer coefficient of air on the microscale can reach 60–300 times that on the macroscale, which is an important heat transfer mode affecting the temperature field distribution of the electrothermal microgripper. Combined with the finite element simulation software, the temperature field of the electrothermal microgripper could be accurately simulated using the experimental microscale heat transfer parameters measured. This study provides an important theoretical basis and data support for the optimal design of the temperature controller of the electrothermal microgripper.
Biological microdissection has a wide range of applications in the field of molecular pathology. The current laser-assisted dissection technology is expensive. As an economical microdissection method, piezoelectric ultrasonic microdissection has broad application prospects. However, the performance of the current piezoelectric ultrasonic microdissection technology is unsatisfactory. This paper aims to solve the problems of the low dissecting precision and excessive wear of the dissecting needle caused by the harmful lateral vibration of the present piezoelectric ultrasonic microdissection device. A piezoelectric ultrasonic microdissection device based on a novel flexure mechanism is proposed. By analyzing the flexure hinge flexibility, the type of flexure beam and the optimal design parameters are determined. Through harmonic response simulation analysis, the newly designed microdissection device with a vibration-suppressing mechanism achieves the best vibration effect when the driving frequency is 28 kHz. Under this driving frequency, the lateral vibration suppression effect is improved by 68% compared to the traditional effect without vibration suppression. Then, based on 3D printing technology, a prototype of a novel microdissection device is produced, and its performance is tested. Experiments on dissecting needle vibration tests show that the flexure mechanism does indeed suppress the lateral vibration of the needle tip. We conducted various tissue dissection experiments on paraffin tissue sections. First, we determine the optimal dissecting parameters (driving voltage, frequency, feed speed, cutting angle) of the new equipment through various parameter dissecting experiments. Then, we adopt these optimal dissecting parameters to perform three kinds of dissecting experiments on mouse tissue paraffin section (liver, lung, bone), dissecting experiments on tissue sections of different thicknesses (3 μm, 4 μm, 5 μm), sampling and extraction experiments on complete tissue. The new device has a better dissecting performance for paraffin tissue sections below a 5 μm thickness and can complete various dissecting tasks. Finally, we compare the wear of the dissecting needles of the new and old devices after the same dissecting tasks. The results prove that the suppression of harmful lateral vibration not only significantly improves the dissecting effect but also increases the service life and durability of the dissecting needle, which is beneficial for reducing the equipment costs.