It is becoming increasingly crucial to develop methods and strategies to assess building performance under the changing climate and to yield a more sustainable and resilient design. However, the outputs of climate models have a coarse spatial and temporal resolution and cannot be used directly in building energy simulation tools. This paper reviews methods to develop fine spatial and temporal weather files that incorporate climate emissions scenarios by means of downscaling. An overview of the climate change impact on building energy performance is given, and potential adaptation and mitigation factors in response to the changing climate in the building sector are presented. Also, methods to reflect, propagate, and partition main sources of uncertainties in both weather files and buildings are summarized, and a sample approach to propagate the uncertainties is demonstrated.
Opportunistic premise plumbing pathogens such as Pseudomonas aeruginosa and Naegleria fowleri are a growing concern in building water systems because of their potential risks to human health. The aim of this study was to determine the critical concentrations of P. aeruginosa and N. fowleri in water that are associated with meaningful public health risks. To determine these concentrations, a reverse quantitative microbial risk assessment (QMRA) was conducted. Environmental concentrations of P. aeruginosa and N. fowleri corresponding to the risk target of one micro-disability-adjusted life year (DALY) per person per year and 10−4 annual risks of illness were calculated for several applicable exposure scenarios. To calculate the concentration of P. aeruginosa, cleaning contact lenses with potentially contaminated tap water in the absence of an appropriate cleaning solution was considered. For N. fowleri, two exposure scenarios, recreational exposure (swimming) and nasal cleansing (via the use of a neti pot™ or similar device) were considered. The highest critical concentration for P. aeruginosa was found to be 33 CFU/L with a 95% confidence interval of (2.0, 118) for the drop exposure scenario using the 10−4 annual risk target. For N. fowleri, based on the DALY approach, critical concentrations were 0.000030 N. fowleri/L for swimming and 0.00000060 N. fowleri/L for neti pot™ use scenario. Considering heat inactivation, the critical concentration limits for P. aeruginosa using the DALY approach and the 10−4 annual risk target approach were found to be 0.55 CFU/L and 55 CFU/L, respectively. For N. fowleri, the 10−4 annual risk target approach resulted in 0.022 N. fowleri/L and the DALY approach resulted in 0.00000064 N. fowleri/L for the neti pot™ scenario. For P. aeruginosa, N50 (the median infective dose) and alpha (α) contributed the most and contact rates the least to the variability and uncertainty of the estimates for all the scenarios. For N. fowleri, N50 and contact rates contributed the most and α the least to the variability and uncertainty to calculate the concentrations for all the scenarios. The QMRA framework implemented in this research can be used to incorporate more information regarding opportunistic pathogens to inform management decisions, and to prioritize the best interventions regarding estimated reduction in infections caused by opportunistic pathogens.
Buildings are subject to significant stresses due to climate change and design strategies for climate resilient buildings are rife with uncertainties which could make interpreting energy use distributions difficult and questionable. This study intends to enhance a robust and credible estimate of the uncertainties and interpretations of building energy performance under climate change. A four-step climate uncertainty propagation approach which propagates downscaled future weather file uncertainties into building energy use is examined. The four-step approach integrates dynamic building simulation, fitting a distribution to average annual weather variables, regression model (between average annual weather variables and energy use) and random sampling. The impact of fitting different distributions to the weather variable (such as Normal, Beta, Weibull, etc.) and regression models (Multiple Linear and Principal Component Regression) of the uncertainty propagation method on cooling and heating energy use distribution for a sample reference office building is evaluated. Results show selecting a full principal component regression model following a best-fit distribution for each principal component of the weather variables can reduce the variation of the output energy distribution compared to simulated data. The results offer a way of understanding compound building energy use distributions and parsing the uncertain nature of climate projections.
Buildings are subject to many uncertainties ranging from thermophysical performance to user activity. Climate change is an additional source of uncertainty that complicates building performance evaluation. This study aims to quantify the share of uncertainties stemming from building factors, user behavior, and climate uncertainty from boilers, chillers, fans, pumps, total HVAC systems, and total site energy use. A novel method combining Monte Carlo analysis and ANOVA is proposed to partition uncertainties from building energy simulation results under different climate change scenarios. The Monte Carlo method is used to generate distributions of building and user factors as building simulation inputs. Then, simulation results under current and future climate conditions are post-processed using a three-way ANOVA technique to discretize the uncertainties for a reference office building in Philadelphia, PA. The proposed method shows the share in percentages of each input factor (building, user, and climate) in the total uncertainty of building energy simulation output results. Our results indicate that the contribution of climate uncertainty increases from current conditions to future climate scenarios for chillers, boilers, fans, and pumps’ electricity use. User parameters are the dominant uncertainty factor for total site energy use and fans’ electricity use. Moreover, boiler and HVAC energy use are highly sensitive to the shape and range of user and building input factor distributions. We underline the importance of selecting the appropriate distribution for input factors when partitioning the uncertainties of building performance modeling.
The authors regret to report that the paper “Reverse QMRA as a Decision Support Tool: Setting Acceptable Concentration Limits for Pseudomonas aeruginosa and Naegleria fowleri” contains some erroneous computations
Climate change, caused by increased emissions produced by human activities, can make a building deviate from its original design and disrupt building energy operations. Building designs need to account for future climate scenarios and effective adaptation and mitigation measures are needed. However, the future is unknown, and climate models only present a snapshot of what the future climate may look like and have many uncertainties. Building energy operations can also be influenced by users and building thermophysical factors which are dynamic and can change through time. Climate uncertainty adds to this uncertainty and complicates evaluating building energy performance and makes classical deterministic approaches in assessing building energy unreliable. Therefore, there is an urgent need for analytical methods in building design to account for climate change while considering uncertainties. This work investigated a critical gap in our understanding of how to address uncertainties associated with building energy use under competing climate change scenarios over their lifetime. The scientific innovation of this work is the integration of climate change-driven building energy modeling with uncertainty analysis. First, the impact of climate change on building energy use and potential response measures are given. Next, methods to generate future weather files which can be directly incorporated into building energy use are examined. Then, a hybrid method to quantify the share of uncertainties from building factors, users and climate is presented by combining ANOVA and Monte Carlo analysis. Finally, a new method is proposed to propagate climate change uncertainties into building energy use by combining regression analysis and Monte Carlo. It was found that downscaling climate models using weather generators can add to existing uncertainties. Buildings should be designed through a framework of possibilities and vulnerabilities to reflect a range of solutions that best suits the intended design. The uncertainty partitioning method has the potential to show the share of uncertainties from climate, user and building factors for any energy use indicator up to the end century. The method was found to be sensitive to input distributions of uncertainty factors. The uncertainty propagation method can be used to provide valuable insight on interpreting the impact of climate uncertainties on building energy use. It can be used where limited future weather files can be generated and reduces computational needs. Results of this work can be leveraged towards enhancing analytical methods in building designs and simulation tools under climate change and towards overcoming limitations of classical approach.