Hamed Shayestehpour

Dr. Hamed Shayestehpour


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2021 in Multibody System Dynamics
Verified
Journal Article
Closed access
PDF file
HSHamed Shayestehpour
Hamed Shayestehpour
John RasmussenJohn Rasmussen
John Rasmussen
PGPavel Galibarov
Pavel Galibarov
CWChristian Wong
Christian Wong

20 September 2017 in Scientia Iranica
Verified
Journal Article
Open access
PDF file
HSHamed Shayestehpour
Hamed Shayestehpour
KNK. Nassiri Nazif
K. Nassiri Nazif
ASA. M. Soufi
A. M. Soufi
MSMohammad Said Saidi
Mohammad Said Saidi
Recently, electrode-based Dielectrophoresis (eDEP) has been used for particle manipulation by means of triangular electrodes. In this theoretical and numerical study, a microchannel with quarter-of-ellipse electrodes is presented and a detailed comparison with triangular electrodes is made. Electric field, resultant DEP force, and particle trajectories for each microchannel are evaluated by means of COMSOL Multiphysics 4.4. Afterwards focusing and separation efficiencies of the systems are assessed and compared. Finally, our proposed model’s separation efficiency of live and dead cells is compared with our previous model published in the literature [1]. It is demonstrated that our proposed model have higher lateral DEP force, responsible for cell separation, compared to the previous triangular-electrode model. This feature is reflected in the 96% focusing efficiency for 10-micron particles and 100% separation efficiency for live and dead mammalian cells.

19 April 2025 in Medical Image Analysis
Verified
Journal Article
Open access
CKChristos Koutras
Christos Koutras
HSHamed Shayestehpour
Hamed Shayestehpour
JPJesús Pérez
Jesús Pérez
CWChristian Wong
Christian Wong
John RasmussenJohn Rasmussen
John Rasmussen
MOMiguel Otaduy
Miguel Otaduy
We present a methodology to personalize the stiffness response of a biomechanical model of the torso and the spine. In high contrast to previous work, the proposed methodology uses controlled force-deformation data that mimic the conditions of spinal bracing for scoliosis, which leads to personalized biomechanical models that are suitable for computational brace design. The novel methodology relies on several technical contributions. First, a prototype system that includes controlled force measurement and low-dose radiographs, with low-encumbrance for its implementation in the clinical protocol. Second, a model of differentiable biomechanics of the torso and the spine, which becomes the key building block for robust parameter estimation. And third, an optimization procedure for parameter estimation from force-deformation data, which relies on differentiability of the biomechanics and the image generation process. We demonstrate the application of the methodology to a cohort of 7 subjects who underwent scoliosis check-ups, and we show quantitative validation of the estimated personalized parameters and the improvement over default parameters from the bibliography.

22 October 2024 in Multibody System Dynamics
Verified
Journal Article
Open access
PDF file
HSHamed Shayestehpour
Hamed Shayestehpour
STSøren Tørholm
Søren Tørholm
MDMichael Damsgaard
Michael Damsgaard
MLMorten Enemark Lund
Morten Enemark Lund
CWChristian Wong
Christian Wong
John RasmussenJohn Rasmussen
John Rasmussen
A reliable and comprehensive multibody musculoskeletal model of the thoracic spine and ribcage can offer valuable insight into the biomechanics of healthy and curved spines. In this study, we developed a generic rigid-body thoracic spine and ribcage model, which is kinematically determinate and controlled by spinal posture. A newly devised averaging constraint was implemented to model the kinematics of individual ribs and the sternum. Rib motion validation confirmed that the movement of adjacent ribs matched measured data across different tasks. We simulated 39 adolescent idiopathic scoliosis subjects aged 7–17 years, with an average (SD) Cobb angle of 15.9 (8.2) degrees. The average errors of multiple scoliosis metrics were less than 4 degrees for angle parameters, 5 mm for displacement parameters, and 3 percent for the ratio parameter. The model is straightforward and can simulate various daily activities (e.g., spinal articulation and breathing) while accurately capturing pathological deformities conforming to experimental data. It is available to the public on the open science platform Zenodo and will also be accessible through the AnyBody Managed Model Repository.