Hamish Pope

Dr. Hamish Pope

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2024 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
Hamish PopeHamish Pope
Hamish Pope
The building stock is a large consumer of energy, and measures are being taken to reduce energy use in new construction. However, to reach the world’s net zero goals, significant changes need to be made to existing buildings. There are many different methods that can be used to renovate a building, including partial demolition and rebuilding, interior retrofit, or exterior retrofit. The focus of this review is on prefabricated exterior retrofit projects. The entire process of undergoing industrialized exterior retrofits will be explained, including Initiation and Viability, Building Capture and Imaging, Detailed Design, Manufacturing, Installation, Operation, Maintenance, and Monitoring. Past industrialized retrofit projects will be presented, and their successes and limitations will be discussed. Common issues and barriers to entry/adoption are examined to give an understanding of what is required to make prefabricated industrialized exterior retrofits work in North America.

1 June 2024 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
Hamish PopeHamish Pope
Hamish Pope
MCM Carver
M Carver
BCB Conley
B Conley
There is a need for proven, resilient, scalable building envelope assemblies and construction systems for rapidly decarbonizing and adapting existing Canadian houses and buildings to changing climatic conditions. NRCan’s Prefabricated Exterior Energy Retrofit (PEER) project developed and demonstrated a methodology for mass, deep building retrofit using prefabricated panels. In 2023, CanmetENERGY launched a new project to incorporate promising carbon-storing, but unproven materials into prefabricated retrofit panels. In this paper, carbon-storing materials were evaluated and selected according to a variety of criteria including lifecycle carbon, hygric and thermal properties, constructability, cost, and Canadian availability. The most promising materials were selected and integrated into a panel concept. A panel concept and associated construction details were developed and modelled for embodied carbon and thermal performance. Finally, prototypes were fabricated, and a pilot project was conducted to assess constructability. The modelled thermal resistance of the panel design ranged from RSI 4.65 to 5.04 (depending on insulation material), sufficient to achieve net-zero or passive house performance for typical, existing Canadian homes. Carbon storage potential ranged from 7.6 to 34 kg CO2e/m2. If deployed at scale, such solutions could help to offset the embodied carbon associated with construction of new homes/buildings in Canada each year.

11 October 2025 in Buildings
Verified
Journal Article
Open access
PDF file
Hamish PopeHamish Pope
Hamish Pope
MCMark Carver
Mark Carver
JAJeffrey Kent Armstrong
Jeffrey Kent Armstrong
Deep retrofits are one of the few pathways to decarbonize the existing building stock while simultaneously improving climate resilience. These retrofits improve insulation, airtightness, and mechanical equipment efficiency. NRCan’s Prefabricated Exterior Energy Retrofit (PEER) project developed prefabricated building envelope retrofit solutions to enable net-zero performance. The PEER process was demonstrated on two different pilot projects completed between 2017 and 2023. In 2024, in partnership with industry partners, NRCan developed new low-carbon retrofit panel designs and completed a pilot project to evaluate their performance and better understand resiliency and occupant comfort post-retrofit. The Low-Carbon Climate-Resilient (LCCR) Living Lab pilot retrofit was completed in 2024 in Ottawa, Canada, using low-carbon PEER panels. This paper outlines the design and construction for the pilot, including panel designs, the retrofitting process, and post-retrofit building and envelope commissioning. The retrofitting process included the design and installation of new prefabricated exterior retrofitted panels for the walls and the roof. These panels were insulated with cellulose, wood fibre, hemp, and chopped straw. During construction, blower door testing and infrared imaging were conducted to identify air leakage paths and thermal bridges in the enclosure. The retrofit envelope thermal resistance is RSI 7.0 walls, RSI 10.5 roof, and an RSI 3.5 floor with 0.80 W/m2·K U-factor high-gain windows. The measured normalized leakage area @10Pa was 0.074 cm2/m2. The net carbon stored during retrofitting was over 1480 kg CO2. Monitoring equipment was placed within the LCCR to enable the validation of hygrothermal models for heat, air, and moisture transport, and energy, comfort, and climate resilience models.

1 December 2021 in The Masonry Society Journal
Verified
Journal Article
Open access
PDF file
Hamish PopeHamish Pope
Hamish Pope
EZEhab Zalok
Ehab Zalok
Raked joints are commonly used for aesthetic purposes; however, they have been thought to greatly reduce the fire resistance of masonry. The reason for this is that part of the mortar is removed from the joint, which could cause points of failure and allow for thermal bridging. To determine the effect that raked joints have on the fire resistance, a full-scale concrete masonry wall with raked joints was tested as per the CAN/ULC S101 standard. A wall with standard concave mortar joints was also tested as a control. The walls had supplemental monitoring from thermal imaging and thermocouples throughout the walls in order to record a complete thermal profile. Results showed that the raked joints had a limited impact on the fire resistance of the wall, as the thermocouples and thermal camera showed that the mortar joints were not the most critical parts of the masonry wall. In order to determine the applicability of these findings to other joint types, another test was done with struck joints. The results confirmed that mortar was not the most critical part in terms of the insulation failure, however its effects on integrity were not conclusively determined.

2 December 2020 in The Masonry Society Journal
Verified
Journal Article
Open access
PDF file
Hamish PopeHamish Pope
Hamish Pope
EZEhab Zalok
Ehab Zalok
Masonry blocks are known to be good for thermal insulation. When exposed to the high temperatures of a fire, hollow blocks can still have a significantly long resistance to heat. The effects of conduction, convection, and radiation through hollow blocks have been studied at ambient temperatures to improve the thermal insulation; however, at elevated temperatures the heat transfer methods are not as well studied. Some experiments and models have been created to determine the horizontal heat flow through a block wall at elevated temperatures, and methods to reduce heat flow have been researched. The limitations of these studies are that they do not account for the vertical heat flow inside the cells of the blocks. When a hollow masonry wall is exposed to fire, the top of the wall is hotter than the bottom of the wall due to convection heat transfer. Since most experimental work, in the literature, deals with a single block or small masonry prisms, this vertical heat flow is difficult to study. This paper describes the heat transfer methods in hollow concrete masonry walls and gives an explanation of standardized fire testing. The equivalent thickness method for determining masonry fire resistance is discussed, and its limitations are outlined. The paper focuses on the experimental results of a full-scale test designed to determine the effects of adding a bond beam within a masonry wall, as well as the effects of using reduced web masonry blocks. Heat transfer methods through hollow masonry walls and methods to improve thermal resistance are also discussed. It was found that compartmentalization of hollow masonry blocks and hollow masonry walls played an important role in changing the fire resistance. The compartmentalization reduced the heat transfer via convection and radiation, and allowed for a more uniform temperature distribution. Since hollow masonry blocks are not themselves homogeneous, the surface temperature of the block is different at difference locations. The mortar, the solid web and the hollow cell all transfer heat at a different rate, which causes the surface of the masonry wall to have a non-uniform temperature distribution. It was found that at fire temperatures, heat transferred faster through the hollow cells, which is why finding methods to reduce the temperature in the hollow cells is important for improving the fire resistance of masonry.

1 December 2021 in The Masonry Society Journal
Verified
Journal Article
Open access
PDF file
Hamish PopeHamish Pope
Hamish Pope
EZEhab Zalok
Ehab Zalok
Concrete Masonry has been known to have excellent fire protection properties. Its large thermal mass helps keeping the fire contained and reduces the temperature at the core of the masonry assembly, which allows for a longer time for the loads to be carried. This is important because the mechanical properties of concrete blocks and mortar begin to deteriorate as the material heats up. The main properties that affect the stability and temperature profile of masonry exposed to fire are its thermal expansion, density, thermal conductivity, and specific heat capacity. There can be a large difference in the properties between two concrete mixes, based on factors such as aggregate type, mix design, moisture content, and the addition of supplementary cementitious materials. This paper aims to outline the (a) effects of temperature on the compressive strength of masonry materials and (b) effects of different concrete types on the performance of concrete masonry at fire temperatures. This is done by explaining the chemical and physical changes that concrete undergoes when it is heated, as well as outlining the results from various research work. In conclusion, thermal expansion is an important factor that needs to be taken into account when deciding which materials to use in concrete masonry to reduce negative effects at elevated temperatures and keep the residual compressive strength high. The residual compressive strength of concrete is usually unchanged below 400°C. Above 400°C the strength starts to decrease due to a combination of moisture loss, micro cracks, chemical decomposition, and thermal stresses. The strength loss can be mitigated by using thermal stable aggregate such as lightweight aggregates or certain recycled aggregates. Supplementary cementitious materials can also be used to reduce micro cracking and improve the mechanical properties of concrete at elevated temperatures.