Annular fissures in the intervertebral discs are believed to be closely related to back pain. However, no sensitive non-invasive method exists to detect annular fissures. This study aimed to propose and test a method capable of detecting the presence and position of annular fissures in conventional magnetic resonance (MR) images non-invasively. The method utilizes textural features calculated from conventional MR images combined with attention mapping and artificial intelligence (AI)-based classification models. As ground truth, reference standard computed tomography (CT) discography was used. One hundred twenty-three intervertebral discs in 43 patients were examined with MR imaging followed by discography and CT. The fissure classification model determined the presence of fissures with 100% sensitivity and 97% specificity. Moreover, the true position of the fissures was correctly determined in 90 (87%) of the analyzed discs. Additionally, the proposed method was significantly more accurate at identifying fissures than the conventional radiological high-intensity zone marker. In conclusion, the findings suggest that the proposed method is a promising diagnostic tool to detect annular fissures of importance for back pain and might aid in clinical practice and allow for new non-invasive research related to the presence and position of individual fissures.
In children, non-fractured wrists generally need no treatment and those that are fractured may only require a 3-week cast without any clinical follow-up. The ability to perform a point-of-care triage decision if radiographs are needed could improve patient flow and decrease unnecessary radiographs. The aim of this study was to evaluate the role of ultrasound (US) as a point-of-care triage tool for pediatric wrist injuries with limited training. Physicians with no previous US experience attended a 1.5 h course in the use of US to diagnose distal radius fractures at the Emergency Department (ED). The physicians firstly used US to diagnose a potential fracture and, if the patient had a fracture, grouped the patient according to how they wanted him/her to be treated based on US. The physician then interpreted the subsequent radiographs and decided on a treatment based on this information. Consultant traumatologists and a senior radiologist established a gold standard for correct treatment and radiological diagnosis, respectively. One hundred and sixteen injuries in 115 patients were included. The ED physician identified 75 fractures on radiographs. With the exception of a minimal buckle fracture, all were identified on US. US had a tendency to interpret complete fractures on radiographs as incomplete (n = 7) leading to incorrect treatment decisions. In the hands of an US novice, US examination is comparable with radiographs as a point-of-care tool to distinguish a fractured wrist from a non-fractured one. US is not, however, as good as radiographs for placing fractured wrists into the correct treatment group. Level III. Diagnostic study of non-consecutive patients.
The function of the endplate (EP) is the most important factor influencing nutritional supply to the avascular intervertebral disc (IVD). It is desired to have a non-invasive method to assess functional EP characteristics in vivo. Assessment of functional EP characteristics is important in order to understand its relation to IVD degeneration, which in turn might deepen the understanding of the pathophysiology behind low back pain (LBP). It was hypothesized that, by comparing quantitative MRI of EPs performed with conventional supine MRI (unloaded MRI) with axial loading during MRI (alMRI), dynamical properties of the EP can be displayed. The aim was therefore to investigate the feasibility of axial loading during MRI (alMRI) to instantaneously induce quantitative EP changes. T2 mapping of 55 vertebral EPs (L1-S1) in five LBP patients was performed during conventional supine MRI (unloaded MRI) and subsequent alMRI. With T2 mapping, the cartilaginous EP and bony EP cannot be separated; hence, the visualized EP was termed EP zone (EPZ). Each EPZ was segmented at multiple midsagittal views, generating volumetric regions of interest. EPZs demonstrating signal inhomogeneity and/or adjacent Modic changes (MC) were termed abnormal EPZs. EPZ mean T2 values were compared between unloaded MRI and alMRI, and their relationship with abnormal EPZs was determined. alMRI induced significantly higher (p = 0.01) EPZ mean T2 values compared with unloaded MRI. Significantly higher mean T2 values were seen in inferior EPZs compared with superior EPZs, both with unloaded MRI (35%, p < 0.001) and with alMRI (26%, p = 0.04). Significant difference between unloaded MRI and alMRI was seen in normal (p = 0.02), but not in abnormal EPZs (p = 0.5; n = 12). alMRI induces changes in human EPZ characteristics in vivo. The T2 value significantly increased in normal EPZs, with lack of such in abnormal EPZs. Combining T2 mapping with alMRI provides a clinical feasible, non-invasive method with potential to reveal biochemical behavioral patterns, thus adding another dimension of the EPZs characteristics compared with information obtained with solely unloaded MRI.
Aim: To evaluate the feasibility of multiple ultrasound markers for the non-invasive characterization of fibrosis, inflammation and steatosis in the liver in pediatric patients. Materials and methods: The quantitative ultrasound measures shear wave elastography (SWE), shear wave dispersion (SWD) and attenuation imaging (ATI) were compared and correlated with percutaneous liver biopsies and corresponding measures in a control cohort. Results: The median age of the 32 patients was 12.1 years (range 0.1–17.9), and that of the 15 controls was 11.8 years (range: 2.6–16.6). Results: There was a significant difference in SWE values between histologic grades of fibrosis (p = 0.003), with a positive correlation according to the grade (r = 0.7; p < 0.0001). Overall, a difference in SWD values between grades of inflammation was found (p = 0.009) but with a lack of correlation (r = 0.1; p = 0.67). Comparing inflammation grades 0–1 (median:13.6 m/s kHz [min; max; 8.4; 17.5]) versus grades 2–3 (16.3 m/s kHz [14.6; 24.2]) showed significant differences between the groups (p = 0.003). In the 30 individuals with a steatosis score of 0, ATI was measured in 23 cases with a median value of 0.56 dB/cm/MHz. Conclusion: Comprehensive ultrasound analysis was feasible to apply in children and has the potential to reflect the various components of liver affection non-invasively. Larger studies are necessary to conclude to what extent these image-based markers can classify the grade of fibrosis, inflammation and steatosis.