Hans Martin

Dr. Hans Martin

Research, SenseAir (Sweden), Delsbo, Sweden
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2019 in Optics Letters
Verified
Journal Article
Closed access
PDF file
FOFloria Ottonello-Briano
Floria Ottonello-Briano
CECarlos Errando-Herranz
Carlos Errando-Herranz
HRHenrik Rödjegård
Henrik Rödjegård
HMHans Martin
Hans Martin
HSHans Sohlström
Hans Sohlström
KGKristinn Gylfason
Kristinn Gylfason
Carbon dioxide ( C O 2 ) is a gas vital for life on Earth. It is also a waste product of human activities and is widely used in agriculture and industry. Its accurate sensing is therefore of great interest. Optical sensors exploiting the mid-infrared light absorption of C O 2 provide high selectivity, but their large size and high cost limit their use. In this Letter, we demonstrate C O 2 gas sensing at 4.2 µm wavelength using an integrated silicon waveguide, featuring a sensitivity to C O 2 of 44% that of free-space sensing. The suspended waveguide is fabricated on a silicon-on-insulator substrate by a single-lithography-step process, and we route it into a mid-infrared photonic circuit for on-chip-referenced gas measurements. Its demonstrated performance and its simple and scalable fabrication make our waveguide ideal for integration in miniaturized C O 2 sensors for distributed environmental monitoring, personal safety, and medical and high-volume consumer applications.

29 March 2018 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
MKMartin Kunz
Martin Kunz
Jost LavricJost Lavric
Jost Lavric
CGChristoph Gerbig
Christoph Gerbig
PTPieter Tans
Pieter Tans
DNDon Neff
Don Neff
MHMartin Heimann
Martin Heimann
Unmanned aircraft systems (UASs) could provide a cost-effective way to close gaps in the observation of the carbon cycle, provided that small yet accurate analysers are available. We have developed a COmpact Carbon dioxide analyser for Airborne Platforms (COCAP). The accuracy of COCAP's carbon dioxide (CO2) measurements is ensured by calibration in an environmental chamber, regular calibration in the field and by chemical drying of sampled air. In addition, the package contains a lightweight thermal stabilisation system that reduces the influence of ambient temperature changes on the CO2 sensor by 2 orders of magnitude. During validation of COCAP's CO2 measurements in simulated and real flights we found a measurement error of 1.2 µmol mol−1 or better with no indication of bias. COCAP is a self-contained package that has proven well suited for the operation on board small UASs. Besides carbon dioxide dry air mole fraction it also measures air temperature, humidity and pressure. We describe the measurement system and our calibration strategy in detail to support others in tapping the potential of UASs for atmospheric trace gas measurements.

29 October 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
BWBenoit Wastine
Benoit Wastine
CHChristine Hummelgård
Christine Hummelgård
MBMaksym Bryzgalov
Maksym Bryzgalov
HRHenrik Rödjegård
Henrik Rödjegård
HMHans Martin
Hans Martin
SSStephan Schröder
Stephan Schröder
We report on a novel, cost-effective non-dispersive infrared (NDIR) multi-gas sensor aimed at environmental air pollution monitoring. The rugged design of the K96 sensor core combines highest compactness and low-power consumption with our unique multi-channel cell design, featuring the detection of up to three different gases simultaneously, including CO2, CH4, N2O, and H2O. Our sensing platform allows the selection of the target gases as well as the concentration ranges, thus providing highly customizable gas sensor systems targeting application-specific gas monitoring settings. The sensor core comes with an implemented calibration model, and can address in real time any cross-sensitivity between the NDIR gas-sensing channels. We provide an immensely versatile sensing system while ensuring high sensing stability combined with high precision (<0.1 ppm for both CO2 and N2O, <0.5 ppm for CH4). The K96 multi-gas sensor core offers a resilient sensor solution for the increasing demand of compact monitoring systems in the field of environmental monitoring at reasonable costs for medium-to-high volumes.

3 October 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SCSanghoon Chin
Sanghoon Chin
JZJérôme Van Zaen
Jérôme Van Zaen
SDSéverine Denis
Séverine Denis
EMEnric Muntané
Enric Muntané
SSStephan Schröder
Stephan Schröder
SLSteve Lecomte
Steve Lecomte
We demonstrate the successful implementation of an artificial neural network (ANN) to eliminate detrimental spectral shifts imposed in the measurement of laser absorption spectrometers (LASs). Since LASs rely on the analysis of the spectral characteristics of biological and chemical molecules, their accuracy and precision is especially prone to the presence of unwanted spectral shift in the measured molecular absorption spectrum over the reference spectrum. In this paper, an ANN was applied to a scanning grating-based mid-infrared trace gas sensing system, which suffers from temperature-induced spectral shifts. Using the HITRAN database, we generated synthetic gas absorbance spectra with random spectral shifts for training and validation. The ANN was trained with these synthetic spectra to identify the occurrence of spectral shifts. Our experimental verification unambiguously proves that such an ANN can be an excellent tool to accurately retrieve the gas concentration from imprecise or distorted spectra of gas absorption. Due to the global shift of the measured gas absorption spectrum, the accuracy of the retrieved gas concentration using a typical least-mean-squares fitting algorithm was considerably degraded by 40.3%. However, when the gas concentration of the same measurement dataset was predicted by the proposed multilayer perceptron network, the sensing accuracy significantly improved by reducing the error to less than ±1% while preserving the sensing sensitivity.

7 November 2017
Verified
Other
Open access
MKMartin Kunz
Martin Kunz
Jost LavricJost Lavric
Jost Lavric
CGChristoph Gerbig
Christoph Gerbig
PTPieter Tans
Pieter Tans
DNDon Neff
Don Neff
MHMartin Heimann
Martin Heimann

7 November 2017 in EGUsphere
Verified
Preprint
Open access
PDF file
MKMartin Kunz
Martin Kunz
Jost LavricJost Lavric
Jost Lavric
CGChristoph Gerbig
Christoph Gerbig
PTPieter Tans
Pieter Tans
DNDon Neff
Don Neff
MHMartin Heimann
Martin Heimann
Unmanned aircraft systems (UASs) could provide a cost-effective way to close gaps in the observation of the carbon cycle, provided that small yet accurate analysers are available. We have developed a COmpact Carbon dioxide analyser for Airborne Platforms (COCAP). The accuracy of COCAP's carbon dioxide (CO2) measurements is ensured by calibration in an environmental chamber, regular calibration in the field and by chemical drying of sampled air. In addition, the package contains a lightweight thermal stabilisation system that reduces the influence of ambient temperature changes on the CO2 sensor by 2 orders of magnitude. During validation of COCAP's CO2 measurements in simulated and real flights we found a measurement error of 1.2 µmol mol−1 or better with no indication of bias. COCAP is a self-contained package that has proven well suited for the operation on board small UASs. Besides carbon dioxide dry air mole fraction it also measures air temperature, humidity and pressure. We describe the measurement system and our calibration strategy in detail to support others in tapping the potential of UASs for atmospheric trace gas measurements.