Hansol Lim

Prof. Dr. Hansol Lim

Department of building and plant engineering, Hanbat National University, Daejeon, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2018 in Energies
Verified
Journal Article
Open access
PDF file
HLHansol Lim
Hansol Lim
SCSeong-Yong Cheon
Seong-Yong Cheon
JAE-WEON JEONGJAE-WEON JEONG
JAE-WEON JEONG
This study aims to estimate the performance of thermoelectric module (TEM) heat pump for simultaneous liquid cooling and heating and propose empirical models for predicting the heat exchange effectiveness. The experiments were conducted to investigate and collect the performance data of TEM heat pump where the working fluid was water. A total of 57 sets of experimental data were statistically analyzed to estimate the effects of each independent variable on the heat exchange effectiveness using analysis of variance (ANOVA). To develop the empirical model, the six design parameters were measured: the number of transfer units (NTU) of the heat exchangers (i.e., water blocks), the inlet water temperatures and temperatures of water blocks at the cold and hot sides of the TEM. As a result, two polynomial equations predicting heat exchange effectiveness at the cold and hot sides of the TEM heat pump were derived as a function of the six selected design parameters. Also, the proposed models and theoretical model of conventional condenser and evaporator for heat exchange effectiveness were compared with the additional measurement data to validate the reliability of the proposed models. Consequently, two conclusions have been made: (1) the possibility of using the TEM heat pump for simultaneous cooling and heating was examined with the maximum temperature difference of 30 °C between cold and hot side of TEM, and (2) it is revealed that TEM heat pump has difference with the conventional evaporator and condenser from the comparison results between the proposed models and theoretical model due to the heat conduction and Joule effect in TEM.

23 January 2020 in Materials
Verified
Journal Article
Open access
PDF file
HLHansol Lim
Hansol Lim
JAE-WEON JEONGJAE-WEON JEONG
JAE-WEON JEONG
The purpose of this study is to investigate the suitable operation and performance of a thermoelectric radiant panel (TERP) in the heating operation. First, the hypothesis was suggested that the heating operation of TERP can operate without a heat source at the cold side according to theoretical considerations. To prove this hypothesis, the thermal behavior of the TERP was investigated during the heating operation using a numerical simulation based on the finite difference method. The results indicated that it is possible to heat the radiant panel using a thermoelectric module without fan operation via the Joule effect. A mockup model of the TERP was constructed, and the numerical model and hypothesis were validated in experiment 1. Moreover, experiment 2 was performed to evaluate the necessity of fan operation in the heating operation of TERP regarding energy consumption. The results revealed that the TERP without fan operation showed the higher coefficient of performance (COP) in the heating season. After determining the suitable heating operation of the TERP, prediction models for the heating capacity and power consumption of the TERP were developed using the response surface methodology. Both models exhibited good R2 values of >0.94 and were validated within 10% error bounds in experimental cases. These prediction models are expected to be utilized in whole-building simulation programs for estimating the energy consumption of TERPs in the heating mode.

1 March 2016 in Building and Environment
Verified
Journal Article
Closed access
HLHansol Lim
Hansol Lim
MIMuhammad Imran
Muhammad Imran
JJJin Yong Jeon
Jin Yong Jeon

1 June 2023 in Applied Thermal Engineering
Verified
Journal Article
Closed access
HLHansol Lim
Hansol Lim
SCSeong-Yong Cheon
Seong-Yong Cheon
HCHye-Jin Cho
Hye-Jin Cho
JAE-WEON JEONGJAE-WEON JEONG
JAE-WEON JEONG
YSYuehong Su
Yuehong Su

28 June 2024 in Energy and Buildings
Verified
Journal Article
Closed access
JLJae-Hee Lee
Jae-Hee Lee
BKBosun Kim
Bosun Kim
HCHyungwook Chu
Hyungwook Chu
JYJeehoon Yang
Jeehoon Yang
HLHansol Lim
Hansol Lim
JAE-WEON JEONGJAE-WEON JEONG
JAE-WEON JEONG

2 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
SLSoo-Jin Lee
Soo-Jin Lee
HLHansol Lim
Hansol Lim
JAE-WEON JEONGJAE-WEON JEONG
JAE-WEON JEONG
The objective of this study was to modify an existing liquid desiccant and indirect/direct evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS) for humidification operation in winter. The energy benefit of the liquid desiccant-assisted humidification approach during the operation of LD-IDECOAS over the conventional method with a steam humidifier was evaluated through a detailed energy simulation. The humidification and enthalpy effectiveness values of the liquid desiccant humidification measured from laboratory tests were 0.41 and 0.49, respectively, which were applied to the energy simulation for the modified system. Both systems with the proposed and conventional humidification approaches were simulated using an engineering equation solver combined with a TRNSYS 18 energy simulation program. The results demonstrated that the modified LD-IDECOAS consumes less energy for humidification compared to the existing system with a steam humidifier. The proposed system also exhibited considerable heating energy-saving potential. Consequently, modified LD-IDECOAS consumed 42% less primary energy during winter operation after being modified for liquid desiccant-assisted humidification.