Hareesha Nagarajappa

Dr. Hareesha Nagarajappa

Mangalore University, Mangalore, India
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
Verified
Journal Article
Closed access
Hareesha NagarajappaHareesha Nagarajappa
Hareesha Nagarajappa
JMJ.G. Manjunatha
J.G. Manjunatha
BAB.M. Amrutha
B.M. Amrutha
NSN. Sreeharsha
N. Sreeharsha
SAS.M. Basheeruddin Asdaq
S.M. Basheeruddin Asdaq
KAKhalid Anwer
Khalid Anwer

17 June 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Hareesha NagarajappaHareesha Nagarajappa
Hareesha Nagarajappa
J.G ManjunathaJ.G Manjunatha
J.G Manjunatha
The current study explicates the electro-oxidation behavior of formoterol fumarate (FLFT) in the presence of uric acid (UA) on the surface of poly thiazole yellow-G (TY-G) layered multi-walled carbon nanotube paste electrode (MWCNTPE). The modified (Poly(TY-G)LMWCNTPE) and unmodified (MWCNTPE) electrode materials were characterized through electrochemical impedance spectroscopy (EIS), field emission scanning electron microscopy (FE-SEM), and cyclic voltammetry (CV) approaches. The characterization data confirms the good conducting and electrocatalytic nature with more electrochemical active sites on the Poly(TY-G)LMWCNTPE than MWCNTPE towards the FLFT analysis in the presence of UA. Poly(TY-G)LMWCNTPE easily separates the two drugs (FLFT and UA) even though they both have nearer oxidation peak potential. The electro-catalytic activity of the developed electrode is fast and clear for FLFT electro-oxidation in 0.2 M phosphate buffer (PB) of pH 6.5. The Poly(TY-G)LMWCNTPE offered a well-resolved peak with the highest electro-oxidation peak current at the peak potential of 0.538 V than MWCNTPE. The potential scan rate and oxidation peak growth time studies show the electrode reaction towards FLFT electro-oxidation is continued through a diffusion-controlled step. The variation of concentration of FLFT in the range from 0.2 to 1.5 µM (absence of UA) and 3.0 to 8.0 μM (presence of UA) provides a good linear relationship with increased peak current and a lower limit of detection (LOD) values of 0.0128 µM and 0.0129 µM, respectively. The prepared electrode gives a fine recovery for the detection of FLFT in the medicinal sample with acceptable repeatability, stability, and reproducibility.

4 January 2021 in Journal of Electronic Materials
Verified
Journal Article
Closed access
PDF file
Hareesha NagarajappaHareesha Nagarajappa
Hareesha Nagarajappa
J.G ManjunathaJ.G Manjunatha
J.G Manjunatha
BAB. M. Amrutha
B. M. Amrutha
PPP. A. Pushpanjali
P. A. Pushpanjali
MCM. M. Charithra
M. M. Charithra
NSN. Prinith Subbaiah
N. Prinith Subbaiah

10 November 2020 in Materials Research Innovations
Verified
Journal Article
Closed access
PPPemmatte A. Pushpanjali
Pemmatte A. Pushpanjali
J.G ManjunathaJ.G Manjunatha
J.G Manjunatha
BABalliamada M. Amrutha
Balliamada M. Amrutha
Hareesha NagarajappaHareesha Nagarajappa
Hareesha Nagarajappa
The applicability of Curcumin (CRC) as a medicinal remedy for various health issues and as an anti-inflammatory agent, it is of great importance to develop an effortless, sensitive methodology for its determination. In the present research, CRC was determined electrochemically via voltammetric techniques using poly(L-arginine) modified carbon nanotube paste sensor (PArMCNTPS). Different parameters (pH, scan rate, number of polymerisation cycle) were optimised using cyclic voltammetry. CRC displayed well-defined oxidative and reductive peaks at 0.24 V and 0.16 V, respectively. The efficacy of the electrode towards the concurrent detection of CRC was examined in the presence of Riboflavin and Ascorbic acid. Detection of CRC by PArMCNTPS through differential pulse voltammetry technique was achieved from 2 × 10−7 M to 5 × 10−6 M and it presents adequately low detection (6.62 × 10−8 M) and quantification (2.20 × 10−7 M) limits. Furthermore the developed sensor was employed to determine CRC in turmeric powder to validate its analytical application. Graphical Abstract

1 December 2020 in Journal of Electroanalytical Chemistry
Verified
Journal Article
Closed access
Hareesha NagarajappaHareesha Nagarajappa
Hareesha Nagarajappa
JMJ.G. Manjunatha
J.G. Manjunatha

6 May 2022 in Journal of Electroanalytical Chemistry
Verified
Journal Article
Closed access
Hareesha NagarajappaHareesha Nagarajappa
Hareesha Nagarajappa
JMJ.G. Manjunatha
J.G. Manjunatha
ZAZeid A. Alothman
Zeid A. Alothman
MSMika Sillanpää
Mika Sillanpää