Hasanain A. Abdul Wahhab

Dr. Hasanain A. Abdul Wahhab

University of Technology - Iraq
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2024 in Results in Engineering
Verified
Journal Article
Open access
AHAmeer Hasan Hamzah
Ameer Hasan Hamzah
AAAbdulrazzak Akroot
Abdulrazzak Akroot
Hasanain A. Abdul WahhabHasanain A. Abdul Wahhab
Hasanain A. Abdul Wahhab
RGRabeea M. Ghazal
Rabeea M. Ghazal
AAAbdulrahman E J Alhamd
Abdulrahman E J Alhamd
MBMothana Bdaiwi
Mothana Bdaiwi

10 May 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HKHayder Q. A. Khafaji
Hayder Q. A. Khafaji
Hasanain A. Abdul WahhabHasanain A. Abdul Wahhab
Hasanain A. Abdul Wahhab
SASAJDA S. ALSAEDI
SAJDA S. ALSAEDI
WAWisam Abed Kattea Al-Maliki
Wisam Abed Kattea Al-Maliki
Falah AlobaidFalah Alobaid
Falah Alobaid
BEBernd Epple
Bernd Epple
Features of the tubular type of heat exchanger were examined experimentally in the current study. A rig is fitted with a novel insert as a negative heat transfer increase technique. The core fluid used is air under steady heat flux and a turbulent discharge state (6000 ≤ Re ≤ 19,500) conditions. Two heat transfer augmentation inserts are employed; one is the basket turbulators utilized as a turbulator and placed inside the heat exchanger with a constant pitch ratio (PR = 150 mm), and the other is the basket turbulators together with twisted tape that are installed at the core of the basket turbulators. The measurements illustrated that the Nusselt number (Nu) was found to be higher by about 131.8%, 169.5%, 187.7%, and 206.5% in comparison with the plain heat exchanger for basket turbulators and the combined basket–twisted tape inserts with y/w = 6, 3, and 2, respectively. The highest thermal efficiency factor of the increased tubular heat exchanger is 1.63 times more elevated than that of the simple heat exchanger on average, due to a binary basket-quirky strip for a twisting percentage y/w equal to 2 under steady pumping energy. Further, practical correlations for the Nusselt number, as well as friction characteristics, were established and presented.

1 December 2017 in Alexandria Engineering Journal
Verified
Journal Article
Open access
MEM. El-Adawy
M. El-Adawy
MHM.R. Heikal
M.R. Heikal
AAA. Rashid A. Aziz
A. Rashid A. Aziz
MSM.I. Siddiqui
M.I. Siddiqui
Hasanain A. Abdul WahhabHasanain A. Abdul Wahhab
Hasanain A. Abdul Wahhab
In-cylinder air flow structures are known to strongly impact on the performance and combustion of internal combustion engines (ICE). Therefore the aim of this paper is to experimentally study an IC engine in-cylinder flow under steady-state conditions. Different methods can be used to characterize the in-cylinder flow which are optical engines and laser diagnostics, computational fluid dynamic and steady-state flow bench. Here we are concentrating on two different types of flow benches. The first (Ricardo) uses the impulse torque meter method while the other (FEV) uses the paddle wheel technique. The experiments were carried out on the same cylinder head and the same pressure difference across the inlet valves of 600 mmH2O in order to compare the results. The experimental results are presented in terms of the measured air flow rate, flow coefficient, discharge coefficient and non-dimensional rig tumble. Moreover, number of modifications were conducted on the FEV flow bench in order to apply particle image velocimetry measurements on the vertical tumble plane, which passing through the middle of the cylinder at different valve lifts. The results show that a reasonably good level of agreement can be achieved between both methods, providing the methods of calculations of the various parameters are consistent. Keywords: In-cylinder flow, Flow bench, Tumble motion, Flow coefficient, Particle image velocimetr

26 August 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HKHayder Q. A. Khafaji
Hayder Q. A. Khafaji
Hasanain A. Abdul WahhabHasanain A. Abdul Wahhab
Hasanain A. Abdul Wahhab
WAWisam Abed Kattea Al-Maliki
Wisam Abed Kattea Al-Maliki
Falah AlobaidFalah Alobaid
Falah Alobaid
BEBernd Epple
Bernd Epple
In the present experimental work, the energy and exergy for single slope passive solar still with different basin water depths are experimentally investigated under the Baghdad climate condition. The analysis is performed using the governing equations formulated according to the first and second laws of thermodynamics. Compared to solar still with 1 cm water depth, the obtained results indicated that raising the water depth to 2 and 3 cm caused an appreciable drop in water basin temperature, and high levels of water basin reduction were about 4% and 9%, respectively, from 8:00 a.m. to 14:00 p.m., which significantly affects heat and mass transfer and ultimately hinders further water productivity. The maximum evaporation and convection heat transfer coefficients are found (32 W/m2·k) and (2.62 W/m2·k), respectively, while the maximum productivity of solar still is found to be 1468.84 mL/m2 with 1 cm water depth. Conversely, stills with 2 and 3 cm water depth, exhibit an increment of the daily exergy efficiency after 14:00 p.m., this increment was the most for the still with 3 cm water depth. Therefore, we have concluded that the still with 1 cm of water depth attained the highest water productivity, while the still with 3 cm of water depth attained the best exergy efficiency with no additional costs.

28 July 2023 in Results in Engineering
Verified
Journal Article
Open access
MBMothana Bdaiwi
Mothana Bdaiwi
AAAbdulrazzak Akroot
Abdulrazzak Akroot
Hasanain A. Abdul WahhabHasanain A. Abdul Wahhab
Hasanain A. Abdul Wahhab
YAYounus Hamoudi Assaf
Younus Hamoudi Assaf
MNMohammed Y. Nawaf
Mohammed Y. Nawaf
Wadah Talal TalalWadah Talal Talal
Wadah Talal Talal

9 June 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
AKAlaa Fadhil Kareem
Alaa Fadhil Kareem
AAAbdulrazzak Akroot
Abdulrazzak Akroot
Hasanain A. Abdul WahhabHasanain A. Abdul Wahhab
Hasanain A. Abdul Wahhab
Wadah Talal TalalWadah Talal Talal
Wadah Talal Talal
RARabeea M. Ghazal AL-AFFAS
Rabeea M. Ghazal AL-AFFAS
AAALI Isam Yahya Alfaris
ALI Isam Yahya Alfaris
This study focused on exergo–conomic and parametric analysis for Taji station in Baghdad. This station was chosen to reduce the emission of waste gases that pollute the environment, as it is located in a residential area, and to increase the production of electric power, since for a long time, Iraq has been a country that has suffered from a shortage of electricity. The main objective of this work is to integrate the Taji gas turbine’s power plant, which is in Baghdad, with the Rankine cycle and organic Rankine cycle to verify waste heat recovery to produce extra electricity and reduce emissions into the environment. Thermodynamic and exergoeconomic assessment of the combined Brayton cycle–Rankine cycle/Organic Rankin cycle (GSO CC) system, considering the three objective functions of the First- and Second-Law efficiencies and the total cost rates of the system, were applied. According to the findings, 258.2 MW of power is produced from the GSO CC system, whereas 167.3 MW of power is created for the Brayton cycle (BC) under the optimum operating conditions. It was demonstrated that the overall energy and exergy efficiencies, respectively, are 44.37% and 42.84% for the GSO CC system, while they are 28.74% and 27.75%, respectively, for the Brayton cycle. The findings indicate that the combustion chamber has the highest exergy degradation rate. The exergo–economic factor for the entire cycle is 37%, demonstrating that the cost of exergy destruction exceeds the cost of capital investment. Moreover, the cost of the energy produced by the GSO CC system is USD 9.03/MWh, whereas it is USD 8.24/MWh for BC. The results also indicate that the network of the GSO CC system decreases as the pressure ratio increases. Nonetheless, the GSO CC system’s efficiencies and costs increase with a rise in the pressure ratio until they reach a maximum and then decrease with further pressure ratio increases. The increase in the gas turbine inlet temperature and isentropic efficiency of the air compressor and gas turbine enhances the thermodynamic performance of the system; however, a further increase in these parameters increases the overall cost rates.