The operation of the three-phase standalone inverter is affected by many factors, such as heavy changes in load, unbalanced loads, nonlinear loads, system uncertainties and external disturbances. These are critical weaknesses for the control system of the three-phase inverter to reach robust optimal performance. This paper proposes an adaptive optimal sliding mode control (AOSMC) scheme for a three-phase nonlinear uncertain inverter. This AOSMC strategy solves the problems of nonlinear optimization by adaptive dynamic programming, one of the techniques of reinforcement learning, and overcomes the uncertainties and disturbance effects by a disturbance observer–based sliding mode controller. This algorithm uses only one neural network to approximate the critic; therefore, the burden of computation is significantly reduced. Both the weight matrix of the critic network and the disturbance observer are asymptotically stable. The overall system is guaranteed to be ultimately uniformly bounded stable via Lyapunov stable theory. The simulation is conducted to validate the insensitivity of the proposed AOSMC algorithm to working conditions. Also, the competitive results are presented to demonstrate the improvement of the proposed AOSMC scheme in comparison to some other existing controllers.
9 September 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
In this paper, a reliable hybrid control scheme for distributed DC microgrid is proposed to maintain both the voltage stabilization and power management in the presence of multiple cyber attacks and voltage sensor fault. A dual Kalman filter which separately estimates the secondary control output and DC-link voltage values is implemented to effectively identify the system abnormalities. As soon as the abnormalities such as cyber attacks or sensor failures are detected, the proposed hybrid control scheme instantly changes the operation of the power agents to appropriate control mode to maintain the stability of DCMG system. The proposed hybrid control scheme requires only unidirectional communication links for distributed DC microgrid, which contributes to achieve the consensus in secondary control output with optimal communicational cost. In addition, an adaptive droop curve is also considered in the primary control to minimize the electricity price. The stability of the proposed hybrid control scheme is mathematically analyzed. The reliability of the proposed strategy is verified through several simulations and experimental results.
In this study, to enhance the system reliability under false data injection (FDI) attacks and DC-link voltage (DCLV) sensor failures, a hybrid control strategy for a DC microgrid (DCMG) based on the Lagrange extrapolation and voltage observer is proposed. Under normal conditions without FDI attacks or DCLV sensor failures, the DCMG system works in a distributed control scheme. To enhance the reliability of the system under the DCLV sensor failure or FDI attack, the DCMG system utilizes a hybrid control strategy that combines distributed control with decentralized control. The hybrid control strategy is achieved by the proposed detection algorithms for FDI attacks and DCLV sensor failures. The detection of FDI attacks is accomplished by comparing the predicted secondary controller output based on the Lagrange extrapolation with the actual one. When a power agent detects an FDI attack, its control mode is switched to decentralized control by using the proposed hybrid control strategy. The DCLV sensor failure detection algorithm to enhance system reliability against DCLV sensor failures is achieved by comparing the estimated DCLV with the measured one from the voltage observer. Upon detecting a DCLV sensor failure, the operation of the power agent is switched to the current control mode to sustain the system operation even under DCLV sensor failures. The proposed detection algorithms are simple, effective, and precise, operating without mutual interference that deteriorates the detection accuracy. Simulation and experiments are carried out under various uncertain test conditions to validate the reliability and effectiveness of the proposed control strategy.
1 September 2025 in Optimal Control Applications and Methods