Tracing the root cause of defective products in liquid storage tank (LST) production poses a formidable challenge due to the complex dependencies between production and inspection processes. With associated coupling existing among multiple production processes, and the correspondence between the faults in production processes and inspection links being non-unique, these faults are usually difficult to be directly located via a single inspection process. In this paper, the problem of tracing the root cause of defective LST products, which is caused by process parameter deviations or human operation errors during production, is studied. A root cause tracing method that is based on the dynamic multi-fault diagnosis (DMFD) framework is proposed. First, a factorial hidden Markov model (FHMM) is established to depict the state transition process of the LST product, where its status changes over time and across production processes. This is achieved by considering the product state at each production process as a hidden state and the outcomes of each inspection process as an observation state. Then, the Viterbi algorithm is employed to solve the hidden state transition matrix and diagnostic matrix within the framework of the FHMM. Finally, experimental verification is carried out on a real LST assembly production line, and the influence of imperfect testing on the model accuracy is also considered. The experiment is carried out on an LST assembly line that encompasses three discrete links, including the welding of the upper and lower bodies, the installation of check valves, and the installation of sensors. Experimental results demonstrate that the proposed method achieves significantly more superior performance when compared to existing algorithms.