Hopewell Mlungisi Mnyandu

Mr. Hopewell Mlungisi Mnyandu

Chemistry, University of KwaZulu-Natal, Pietermaritzburg, KwaZulu-Natal, South Africa
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2022 in Separation Science and Technology
Verified
Journal Article
Closed access
HMHopewell Mlungisi Mnyandu
Hopewell Mlungisi Mnyandu
PMPrecious Mahlambi
Precious Mahlambi
An ultrasonic solvent extraction (USE) method followed by liquid chromatography-photodiode array detector has been optimized and applied with and without solid-phase clean-up for analysis of triazines in fruits and vegetables. The correlation coefficient (r2) > 0.999 was obtained for all the analytes at a linear range of 100–1000 µg/L. The recoveries obtained were 75–81% and 86–121% for USE with and without SPE clean-up, respectively, with relative standard deviation <20% implying good accuracy and precision. The detection limits ranged from 1.1–1.8 µg/kg to 0.6–1.0 µg/kg for USE with and without SPE clean-up, respectively. The quantification limits ranged from 3.4–5.2 µg/kg to 1.7–2.9 µg/kg for USE with and without SPE clean-up, respectively. The concentrations of triazines detected in fruits and vegetables ranged from 9 to 222 µg/kg. All the triazines were quantified at levels below the MRLs revealing no threat to human health. It can be concluded that the proposed inexpensive, environmentally friendly method can be effectively employed for regular monitoring of the concentration of the selected triazines fruits and vegetables. Moreover, it can be recommended that ultrasonic solvent extraction can be accurately applied without additional SPE clean-up.

5 June 2026 in Sensors
Verified
Journal Article
Open access
PDF file
HMHopewell Mlungisi Mnyandu
Hopewell Mlungisi Mnyandu
PMPrecious Mahlambi
Precious Mahlambi
MVMun'delanji C. Vestergaard
Mun'delanji C. Vestergaard
Molecularly imprinted polymers (MIPs) have emerged as robust and versatile recognition elements for electrochemical sensing due to their high chemical and mechanical stability, cost-effective fabrication, and excellent selectivity toward target analytes. In recent years, MIP-based electrochemical sensors have gained significant attention for the detection of pharmaceutical contaminants in wastewater, addressing growing environmental and public health concerns. This review provides a comprehensive overview of the fundamental principles of molecular imprinting Emphasis is placed on fabrication strategies and electrochemical detection techniques, including cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectroscopy. Furthermore, it discusses imprinting mechanisms for different classes of contaminants, matrix effects, and other challenges. By critically analyzing recent applications, this work highlights key factors influencing sensor performance, such as sensitivity, selectivity, and detection limits. Finally, we touch on future perspectives, focusing on the development of more reliable, scalable, and environmentally sustainable sensing platforms for real-world wastewater monitoring.