The ability to measure the degree of cure of epoxy resins is an important prerequisite for making manufacturing processes for fibre-reinforced plastics controllable. Since a number of physical properties change during the curing reaction of epoxy resins, a wide variety of measurement methods exist. In this article, different methods for cure monitoring of epoxy resins are applied to a room-temperature curing epoxy resin and then directly compared. The methods investigated include a structure-borne sound acoustic, a dielectric, an optical and a strain-based observation method, which for the first time are measured simultaneously on one and the same resin sample. In addition, the degree of cure is determined using a kinetic resin model based on temperature measurement data. The comparison shows that the methods have considerable but well-explainable differences in their sensitivity, interference immunity and repeatability. Some measurement methods are only sensitive before and around the gel point, while the strain-based measurement method only reacts to the curing from the gel point onwards. These differences have to be taken into account when implementing a cure monitoring system. For this reason, a multi-sensor node is suitable for component-integrated curing monitoring, measuring several physical properties of the epoxy resin simultaneously.
The increasing use of composite materials has led to a greater demand for efficient curing cycles to reduce costs and speed up production cycles in manufacturing. One method to achieve this goal is in-line cure monitoring to determine the exact curing time. This article proposes a novel method through which to monitor the curing process inside closed tools by employing ultrasonic spectroscopy. A simple experiment is used to demonstrate the change in the ultrasonic spectrum during the cure cycle of an epoxy. The results clearly reveal a direct correlation between the amplitude and state of cure. The glass transition point is indicated by a global minimum of the reflected amplitude.
The increasing demand for low cost consistent quality composite materials, especially of the automotive industry, creates the necessity for fast high quality processes. Pultrusion is one of the processes that can fulfill this demand. While the process is highly automated, manufacturing parameters still have to be chosen manually. The choice of line speed, mould temperature and injection pressure is based on best practice and therefore requires manual optimization that results in cost intensive manufacturing errors and suboptimal machine productivity. This paper presents a possible solution for this problem by providing an on-line cure monitoring approach that allows to overcome this challenge. Resonant Ultrasonic Spectroscopy (RUS) shows a high potential for in-line cure monitoring inside the pultrusion tool. RUS has been adapted for the first time in a pultrusion process. This paper focuses on the successful application of this technique to control the pultrusion process based on the state of cure of the material inside of the tool. As one of the only techniques for in-line cure monitoring which can be used continuously in closed tools despite high abrasion, it provides a new insight into the pultrusion process.
With an ever broadening use of composite materials manufacturers are in high demand of efficient curing cycles to reduce costs and speed up production cycles. One method to to archive this goal is active cure monitoring to determine the exact time of curing needed. This article provides a novel method to measure the cure inside of closed tools by using ultrasonic spectroscopy. For this a simple experiment is used to show the change of the ultrasonic spectrum during the cure of an epoxy. The results clearly show a direct correlation of amplitude and state of cure where the amplitude reaches a global minimum at the glass point.
In the field of cure monitoring, resonant ultrasonic cure monitoring is a unique technique to measure the progression of cure of composites in fully or partially closed tools. It allows for the use of electronic hardware that is less sophisticated than traditional pulse-based ultrasonic systems to obtain accurate results. While this technique is not new, it has been used very rarely. One reason for this is the lack of optimized sensors. Commercially available sensors are optimized for pulse-based ultrasonic testing. This paper establishes a possible optimized sensor design for resonant ultrasound cure monitoring using a multi-parameter FE model.
Controlling complex systems by traditional control systems can sometimes lead to sub-optimal results since mathematical models do often not completely describe physical processes. An alternative approach is the use of a neural network based control algorithm. Neural Networks can approximate any function and as such are able to control even the most complex system. One challenge of this approach is the necessity of a high speed training loop to facilitate enough training rounds in a reasonable time frame to generate a viable control network. This paper overcomes this problem by employing a second neural network to approximate the output of a relatively slow 3D-FE-Pultrusion-Model. This approximation is by orders of magnitude faster than the original model with only minor deviations from the original models behaviour. This new model is then employed in a training loop to successfully train a NEAT based genetic control algorithm.