Andreas Ioannidis

Dr. Andreas Ioannidis


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
GPGeorgios Evaggelos Papadopoulos
Georgios Evaggelos Papadopoulos
INIlias Ninios
Ilias Ninios
SESotirios Evangelou Sotirios Evangelou
Sotirios Evangelou Sotirios Evangelou
AIAndreas Ioannidis
Andreas Ioannidis
ANAthinodoros Nikitopoulos
Athinodoros Nikitopoulos
VNVlasis Ninios
Vlasis Ninios
Background/Objectives: Valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) is a key approach for treating degenerated surgical bioprosthetic valves. The ACURATE neo2 valve, with its advanced sealing technology and optimized coronary access, represents a promising solution for the challenges of ViV TAVI. This study evaluates the procedural and 30-day and 1-year follow-up outcomes of the ACURATE neo2 valve in ViV TAVI. Methods: This single-center, single-operator prospective study included patients with symptomatic bioprosthetic valve dysfunction, classified in New York Heart Association (NYHA) class III or IV, who underwent ViV TAVI with ACURATE neo2 at our center between July 2022 and February 2024. Outcomes were assessed using VARC-3 criteria. Results: Fifty-five patients (51% females, median (IQR) age 76 (8) years) were included. The technical success rate was 98.2%. No patients experienced in-hospital mortality, stroke, MI, bleeding, vascular complications, renal failure, or new pacemaker implantation. Three patients (5.5%) underwent elective chimney stenting for coronary protection. The postprocedural mean aortic gradient was 6.7 ± 1 mmHg, with a mean aortic valve area (AVA) of 2.0 ± 0.1 cm2. Over a median follow-up period of 1.2 years, no deaths (0%) were observed, heart failure hospitalization rate was 3.6%, and NYHA class improved to ≤II in 100% of patients. Conclusions: ACURATE neo2 demonstrated excellent technical success, sustained hemodynamic performance, and significant clinical improvement in ViV TAVI. The absence of major adverse events reinforces its safety, efficacy, and durability as a treatment for degenerated surgical bioprostheses.

27 May 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
GPGeorgios Evaggelos Papadopoulos
Georgios Evaggelos Papadopoulos
INIlias Ninios
Ilias Ninios
SESotirios Evangelou Sotirios Evangelou
Sotirios Evangelou Sotirios Evangelou
AIAndreas Ioannidis
Andreas Ioannidis
ANAthinodoros Nikitopoulos
Athinodoros Nikitopoulos
VNVlasis Ninios
Vlasis Ninios
Background/Objectives: Valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) is a key approach for treating degenerated surgical bioprosthetic valves. The ACURATE neo2 valve, with its advanced sealing technology and optimized coronary access, represents a promising solution for the challenges of ViV TAVI. This study evaluates the procedural and short-to-mid-term outcomes of the ACURATE neo2 valve in ViV TAVI. Methods: This single-center, single-operator prospective study included patients with symptomatic bioprosthetic valve dysfunction, classified in New York Heart Association (NYHA) class III or IV, who underwent ViV TAVI with ACURATE neo2 at our center between July 2022 and February 2024. Outcomes were assessed using VARC-3 criteria. Results: Fifty-five patients (51% females, median (IQR) age 76 (8) years) were included. The technical success rate was 98.2%. No patients experienced in-hospital mortality, stroke, MI, bleeding, vascular complications, renal failure, or new pacemaker implantation. Three patients (5.5%) underwent elective chimney stenting for coronary protection. The post-procedural mean aortic gradient was 6.7 ± 1 mmHg, with a mean aortic valve area (AVA) of 2.0 ± 0.1 cm². Over a median follow-up period of 1.2 years, no deaths (0%) were observed, heart failure hospitalization rate was 3.6%, and NYHA class improved to ≤ II in 100% of patients. Conclusions: ACURATE neo2 demonstrated excellent technical success, sustained hemodynamic performance, and significant clinical improvement in ViV TAVI. The absence of major adverse events reinforces its safety, efficacy, and durability as a treatment for degenerated surgical bioprostheses.

13 September 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
GPGeorgios Evaggelos Papadopoulos
Georgios Evaggelos Papadopoulos
INIlias Ninios
Ilias Ninios
SESotirios Evangelou Sotirios Evangelou
Sotirios Evangelou Sotirios Evangelou
AIAndreas Ioannidis
Andreas Ioannidis
VNVlasis Ninios
Vlasis Ninios
Background: Mitral regurgitation (MR) is a common valvular disorder linked to high morbidity and mortality. For patients unsuitable for surgery, transcatheter mitral edge-to-edge repair (TEER) with the MitraClip® G4 system offers an alternative. This study aims to evaluate procedural, echocardiographic, functional, and quality of life (QoL) outcomes in patients who underwent TEER with the MitraClip® G4 system, along with possible predictors of New York Heart Associa-tion (NYHA) class I at 30 days and 1 year. Methods: Patients with moderate-to-severe (3+) or se-vere (4+) degenerative MR (DMR) or functional MR (FMR), classified as NYHA class III or IV, who underwent TEER with the MitraClip® G4 system at our center between January 2021 and De-cember 2023 were included. Results: A total of 83 patients [71% FMR, 66% male, median (IQR) age 70 (11) years] underwent TEER, with 100% procedural success. MR ≤2+ was achieved in 100% and 98% of patients at 30 days and 1 year, respectively. NYHA class I or II was achieved in 100% and 96.8% of patients at 30 days and 1 year, respectively. The Kansas City Cardiomyopathy Ques-tionnaire (KCCQ) score improved from 51±20 at baseline to 69±15 at 30 days (p< 0.001) and 70.5±15 at 1 year (p< 0.001). Lower baseline N-terminal pro-brain natriuretic peptide (NT-proBNP) pre-dicted achieving NYHA class I at 30 days (HR: 0.63, 95% CI: 0.41–0.95, p = 0.030), while lower Eu-ropean System for Cardiac Operative Risk Evaluation II (EuroSCORE II) and NT-proBNP pre-dicted it at 1 year [(HR: 0.50, 95% CI: 0.28–0.89, p = 0.019), (HR: 0.67, 95% CI: 0.44–0.99, p = 0.049), respectively]. Conclusions: The MitraClip® G4 system provides significant improvements in MR severity, functional class, and QoL. Lower NT-proBNP and EuroSCORE II were strong predictors of achieving optimal functional status (NYHA class I).

Verified
Journal Article
Open access
PDF file
GPGeorgios Evaggelos Papadopoulos
Georgios Evaggelos Papadopoulos
INIlias Ninios
Ilias Ninios
SESotirios Evangelou Sotirios Evangelou
Sotirios Evangelou Sotirios Evangelou
AIAndreas Ioannidis
Andreas Ioannidis
VNVlasis Ninios
Vlasis Ninios
Background: Mitral regurgitation (MR) is a common valvular disorder linked to high morbidity and mortality. For patients unsuitable for surgery, transcatheter mitral edge-to-edge repair (TEER) with the MitraClip® G4 system offers an alternative. This study aims to evaluate procedural, echocardiographic, functional, and quality of life (QoL) outcomes in patients who underwent TEER with the MitraClip® G4 system, along with possible predictors of New York Heart Association (NYHA) class I at 30 days and at 1 year. Methods: Patients with moderate-to-severe (3+) or severe (4+) degenerative MR (DMR) or functional MR (FMR), classified as NYHA class III or IV, and who underwent TEER with the MitraClip® G4 system at our center between January 2021 and December 2023 were included. Results: A total of 83 patients [71% FMR, 66% male, median (IQR) age 70 (11) years] underwent TEER, with 100% procedural success. MR ≤ 2+ was achieved in 100% and 98% of patients at 30 days and 1 year, respectively. NYHA class I or II was achieved in 100% and 96.8% of patients at 30 days and 1 year, respectively. The Kansas City Cardiomyopathy Questionnaire (KCCQ) score improved from 51 ± 20 at baseline to 69 ± 15 at 30 days (p < 0.001) and 70.5 ± 15 at 1 year (p < 0.001). Lower baseline N-terminal pro-brain natriuretic peptide (NT-proBNP) predicted achieving NYHA class I at 30 days (HR: 0.63, 95% CI: 0.41–0.95, p = 0.030), while lower European System for Cardiac Operative Risk Evaluation II (EuroSCORE II) and NT-proBNP predicted it at 1 year [(HR: 0.50, 95% CI: 0.28–0.89, p = 0.019), (HR: 0.67, 95% CI: 0.44–0.99, p = 0.049), respectively]. Conclusions: The MitraClip® G4 system provides significant improvements in MR severity, functional class, and QoL. Lower NT-proBNP and EuroSCORE II were strong predictors of achieving optimal functional status (NYHA class I).

8 August 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
GPGeorgios Evaggelos Papadopoulos
Georgios Evaggelos Papadopoulos
INIlias Ninios
Ilias Ninios
ELEleftherios Leptopoulos
Eleftherios Leptopoulos
KPKonstantinos Papazoglou
Konstantinos Papazoglou
KKKonstantinos Konstantinidis
Konstantinos Konstantinidis
VNVlasis Ninios
Vlasis Ninios
Background: Transcatheter aortic valve replacement (TAVR) is a proven treatment for severe aortic stenosis (AS). Transfemoral access is the most prevalent method, achieved either surgically or percutaneously. This study compares in-hospital outcomes and length of stay between surgical cut-down and fully percutaneous approaches. Methods: This retrospective, propensity-matched study analyzed medical records of all patients who underwent transfemoral TAVR at our center from January 2019 to December 2023. Outcomes were assessed based on Valve Academic Research Consortium-2 (VARC-2) consensus criteria. Results: 251 TAVR patients (77 propensity score matching pairs) were included (55% female) with a median (IQR) age of 80 (11) years. Surgical cut-down showed fewer vascular complications, bleeding, and transfusions. No death, stroke, atrial fibrillation (AF), or need for pacemaker was reported in this group. Fewer mean hospitali-zation days were observed in the total cohort over the years (p< 0.001). This reduction was more pronounced after 2021 when the surgical approach was adopted. Mean hospitalization days were 6.40 ±6.46 for percutaneous and 4.34 ±1.61 for surgical groups (p< 0.001). Conclusions: Surgical cut-down for TAVR femoral access yields superior outcomes and shorter hospital stays compared to fully percutaneous methods.