Ian Dimzon

Dr. Ian Dimzon

Ateneo de Manila University
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2017
Verified
Book Chapter
Open access
PDF file
SKSascha Klein
Sascha Klein
IDIan Dimzon
Ian Dimzon
JEJan Eubeler
Jan Eubeler
TKThomas P. Knepper
Thomas P. Knepper
Synthetic polymers are one of the most significant pollutants in the aquatic environment. Most research focused on small plastic particles, so-called microplastics (particle size, 1–5,000 μm). Compared to macroplastics, the small size complicates their determination in environmental samples and demands for more sophisticated analytical approaches. The detection methods of microplastics reported in the past are highly diverse. This chapter summarizes different strategies for the sampling of water and sediment and sample treatments, including the separation of plastic particles and removal of natural debris that are necessary prior the identification of microplastics. Moreover, the techniques used for the identification of plastics particles are presented in this chapter. With the application of the method described in this chapter, microplastics were detected in freshwater systems, such as rivers and lakes worldwide. The abundance of microplastics reported in the studies varied in more than three orders of magnitude. Furthermore, microplastics are not uniform, as there are many different types of synthetic polymers commercially available. Consequently, a variety of different polymer types is present in the aquatic environment. The knowledge on the type of polymer provides additional information for scientists: the type of polymer dictates its physicochemical properties and the degradation. The environmental degradation of plastics is an important factor for the formation, distribution, and accumulation of microplastics in the aquatic system. Thus, this chapter also summarizes the degradation pathways for synthetic polymers in the environment.

1 January 2015 in International Journal of Biological Macromolecules
Verified
Journal Article
Closed access
IDIan Dimzon
Ian Dimzon
TKThomas P. Knepper
Thomas P. Knepper

30 October 2015 in Journal of the American Society for Mass Spectrometry
Verified
Journal Article
Open access
IDIan Dimzon
Ian Dimzon
XTXenia Trier
Xenia Trier
TFTobias Frömel
Tobias Frömel
RHRick Helmus
Rick Helmus
TKThomas P. Knepper
Thomas P. Knepper
PVPim De Voogt
Pim De Voogt
High resolution mass spectrometry (HRMS) was successfully applied to elucidate the structure of a polyfluorinated polyether (PFPE)-based formulation. The mass spectrum generated from direct injection into the MS was examined by identifying the different repeating units manually and with the aid of an instrument data processor. Highly accurate mass spectral data enabled the calculation of higher-order mass defects. The different plots of MW and the nth-order mass defects (up to n = 3) could aid in assessing the structure of the different repeating units and estimating their absolute and relative number per molecule. The three major repeating units were -C2H4O-, -C2F4O-, and -CF2O-. Tandem MS was used to identify the end groups that appeared to be phosphates, as well as the possible distribution of the repeating units. Reversed-phase HPLC separated of the polymer molecules on the basis of number of nonpolar repeating units. The elucidated structure resembles the structure in the published manufacturer technical data. This analytical approach to the characterization of a PFPE-based formulation can serve as a guide in analyzing not just other PFPE-based formulations but also other fluorinated and non-fluorinated polymers. The information from MS is essential in studying the physico-chemical properties of PFPEs and can help in assessing the risks they pose to the environment and to human health.

1 January 2013 in Carbohydrate Polymers
Verified
Journal Article
Closed access
IDIan Dimzon
Ian Dimzon
JEJürgen Ebert
Jürgen Ebert
TKThomas P. Knepper
Thomas P. Knepper

25 November 2016 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
IDIan Dimzon
Ian Dimzon
JWJoke Westerveld
Joke Westerveld
CGChristoph Gremmel
Christoph Gremmel
TFTobias Frömel
Tobias Frömel
TKThomas P. Knepper
Thomas P. Knepper
PVPim De Voogt
Pim De Voogt
Volatile per- and polyfluoroalkyl substances (PFASs) are often used as precursors in the synthesis of nonvolatile PFASs. The volatile PFASs, which include the perfluoroalkyl iodides (PFAIs), fluorotelomer iodides (FTIs), fluorotelomer alcohols (FTOHs), fluorotelomer olefins (FTOs), fluorotelomer acrylates (FTACs), and fluorotelomer methacrylates (FTMACs), are often produced starting from the telomerization process. These volatile compounds can be present in the air and water environment and can be transformed into highly persistent perfluoroalkyl carboxylic acids. With the exception of FTOHs, which are well studied, the determination of other volatile PFASs is also of prime importance in studying the sources and fate of PFASs. In this study, a method was developed to determine representative precursor compounds that included PFAIs, FTIs, FTOs, FTACs, and FTMACs in wastewater treatment plant (WWTP) air and water samples. The sampling and sample preparation step involved the use of solid-phase extraction (SPE) cartridges with HLB™ material to enrich the analyte. Gas chromatography with mass spectrometry was employed for the detection and quantification of the analytes. Method validation results showed high linearity and sensitivity in the positive electron ionization-selected ion monitoring mode (+EI-SIM). The absolute instrumental limits of detection were in the range of 0.5 to 2 pg. The method detection limit (MDL) in air was 1 ng/m3 with the exception of the FTACs which could be only be detected at concentrations higher than 40 ng/m3. The MDL in water was 10 ng/L. Direct spiking of the cartridges and analyte introduction by volatilization from the glass surface onto the SPE material had recoveries between 86 and 100%. The volatile PFASs were shown to readily partition into the air rather than into water. Consequently, large losses in the amount of PFASs were observed when these were spiked into the water. Wastewater treatment plant air and water samples were passed through HLB™ solid-phase materials. The eluates were injected onto a GC-MS system to simultaneously determine the volatile PFASs.

11 August 2011 in Pure and Applied Chemistry
Verified
Journal Article
Closed access
PDF file
FDFabian M. Dayrit
Fabian M. Dayrit
IDIan Dimzon
Ian Dimzon
MVMelodina F. Valde
Melodina F. Valde
JSJaclyn Elizabeth R. Santos
Jaclyn Elizabeth R. Santos
MGMark Joseph Garrovillas
Mark Joseph Garrovillas
BVBlanca J. Villarino
Blanca J. Villarino
Virgin coconut oil (VCO) is a vegetable oil that is extracted from fresh coconut meat and is processed using only physical and other natural means. VCO was compared to refined, bleached, and deodorized coconut oil (RCO) using standard quality parameters, 31P nuclear magnetic resonance (NMR) spectroscopy, and headspace solid-phase micro-extraction/gas chromatography mass spectrometry (SPME/GCMS). VCO tends to have higher free fatty acids (FFAs), moisture, and volatile matter and lower peroxide value than RCO. However, the range of values overlap and no single standard parameter alone can be used to differentiate VCO from RCO. Using 31P NMR, VCO and RCO can be distinguished in terms of the total amount of diglycerides: VCO showed an average content (w/w %) of 1.55, whereas RCO gave an average of 4.10. There was no overlap in the values found for individual VCO and RCO samples. There are four common methods of producing VCO: expeller (EXP), centrifuge (CEN), and fermentation with and without heat. VCO products prepared using these four methods could not be differentiated using standard quality parameters. Sensory analysis showed that VCO produced by fermentation (with and without heat) could be distinguished from those produced using the EXP and CEN methods; this sensory differentiation correlated with the higher levels of acetic acid and octanoic acid in the VCO produced by fermentation. Studies on physicochemical deterioration of VCO showed that VCO is stable to chemical and photochemical oxidation and hydrolysis. VCO is most susceptible to microbial attack, which leads to the formation of various organic acids, in particular, lactic acid. However, at moisture levels below 0.06 %, microbial action is significantly lessened.