Ilyas AIT ICHOU

Mr. Ilyas AIT ICHOU

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2026 in Symmetry
Verified
Journal Article
Open access
PDF file
Ilyas AIT ICHOUIlyas AIT ICHOU
Ilyas AIT ICHOU
SESamir Elouaham
Samir Elouaham
BNBoujemaa Nassiri
Boujemaa Nassiri
JIJamal Isknan
Jamal Isknan
Phonocardiogram (PCG) signals offer a non-invasive, low-cost screening tool for cardiovascular diseases. However, their noisy and non-stationary nature makes automated classification challenging, and traditional methods often fail to capture complex spectral-temporal patterns. This study proposes a multimodal deep learning architecture for the binary classification of heart sounds (Healthy vs. Unhealthy). The hybrid model integrates Convolutional Neural Networks (CNNs), Transformer encoders, and Bidirectional Long Short-Term Memory (BiLSTM) networks with an attention mechanism. It utilizes an early-fusion feature extraction pipeline combining MFCCs, Mel-spectrograms, and Chroma descriptors. To ensure robust evaluation and prevent data leakage, SMOTE is applied exclusively to the training folds within a strict zero-leakage, patient-wise 5-fold cross-validation protocol. The proposed framework demonstrates exceptional performance, achieving an average accuracy of 91.67%, a sensitivity of 80.95%, a specificity of 94.46%, and an AUC-ROC of 96.50%. An ablation study confirms that integrating Transformer and BiLSTM modules significantly enhances diagnostic stability over baseline CNNs. Furthermore, with exactly 858,434 parameters (3.27 MB) and interpretable attention maps, this highly optimized model provides a robust assistive solution suitable for deployment in digital stethoscopes and mobile telemedicine systems.

19 August 2026 in AI
Verified
Journal Article
Open access
PDF file
SESamir Elouaham
Samir Elouaham
FBFatima ezzahra BOUAAZA
Fatima ezzahra BOUAAZA
Ilyas AIT ICHOUIlyas AIT ICHOU
Ilyas AIT ICHOU
BNBoujemaa Nassiri
Boujemaa Nassiri
Diabetic retinopathy (DR) is a common complication of diabetes and one of the leading causes of preventable vision loss worldwide. Because the manual grading of color fundus images is slow and depends on the availability of trained specialists, automated screening tools are needed. This study proposes a lightweight channel-wise refinement strategy for automatic five-class DR grading, built on a ResNet50 backbone. Two custom blocks are evaluated: CBR, which applies a 3 × 3 convolution, batch normalization, and a ReLU activation to make the channel representation more compact, and CBS, which applies a 3 × 3 convolution, batch normalization, and a SiLU activation to reinforce local spatial features. On the Diabetic Retinopathy Balanced dataset, the baseline ResNet50 reached an accuracy of 90.77%, a precision of 90.60%, a recall of 90.79%, and an F1-score of 90.64%. In the ablation study, the best configuration was ResNet50 + CBR, with an accuracy of 91.85%, a precision of 91.75%, a recall of 91.88%, and an F1-score of 91.76%. The full CBR-CBS Hybrid ResNet50 was close behind, with an accuracy of 91.81% and an F1-score of 91.71%. The CBR block accounts for most of this improvement, which suggests that channel-wise refinement helps the model separate subtle lesion patterns. These results establish lightweight channel-wise refinement (CBR) as an effective, compact, and interpretable enhancement of ResNet50 for automated five-class DR grading, delivering a consistent multi-metric gain over the baseline and accuracy competitive with the literature, which makes it a promising solution for large-scale screening.