Imtiaz Alam Shah

Mr. Imtiaz Alam Shah

International Islamic University, Islamabad, Islamabad, Islāmābād, Pakistan
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2024 in Small
Verified
Journal Article
Closed access
USUsman Ali Shah
Usman Ali Shah
AWAo Wang
Ao Wang
MUMuhammad Irfan Ullah
Muhammad Irfan Ullah
MUHAMMAD ISHAQMUHAMMAD ISHAQ
MUHAMMAD ISHAQ
Imtiaz Alam ShahImtiaz Alam Shah
Imtiaz Alam Shah
KSKaiwen Sun
Kaiwen Sun

28 January 2023 in Journal of Engineering Research
Verified
Journal Article
Open access
UIUsama Idrees
Usama Idrees
SASajjad Ahmad
Sajjad Ahmad
Imtiaz Alam ShahImtiaz Alam Shah
Imtiaz Alam Shah
MTMuhammad Talha
Muhammad Talha
RSRehman Shehzad
Rehman Shehzad
SKSeyed Saeid Rahiamin Koloor
Seyed Saeid Rahiamin Koloor

11 March 2022 in Materials
Verified
Journal Article
Open access
PDF file
Imtiaz Alam ShahImtiaz Alam Shah
Imtiaz Alam Shah
RKRafiullah Khan
Rafiullah Khan
Seyed Saeid Rahimian KoloorSeyed Saeid Rahimian Koloor
Seyed Saeid Rahimian Koloor
Michal PetrůMichal Petrů
Michal Petrů
Saeed BadshahSaeed Badshah
Saeed Badshah
MAMuhammad Amjad
Muhammad Amjad
In this study, the ballistic impact behavior of auxetic sandwich composite human body armor was analyzed using finite element analysis. The auxetic core of the armor was composed of discrete re-entrant unit cells. The sandwich armor structure consisted of a front panel of aluminum alloy (Al 7075-T6), UHMWPE (sandwich core), and a back facet of silicon carbide (SiC) bonded together with epoxy resin. Numerical simulations were run on Explicit Dynamics/Autodyne 3-D code. Various projectile velocities with the same boundary conditions were used to predict the auxetic armor response. These results were compared with those of conventional monolithic body armor. The results showed improved indentation resistance with the auxetic armor. Deformation in auxetic armor was observed greater for each of the cases when compared to the monolithic armor, due to higher energy absorption. The elastic energy dissipation results in the lower indentation in an auxetic armor. The armor can be used safely up to 400 m/s; being used at higher velocities significantly reduced the threat level. Conversely, the conventional monolithic modal does not allow the projectile to pass through at a velocity below 300 m/s; however, the back face becomes severely damaged at 200 m/s. At a velocity of 400 m/s, the front facet of auxetic armor was destroyed; however, the back facet was completely safe, while the monolithic panel did not withstand this velocity and was completely damaged. The results are encouraging in terms of resistance offered by the newly adopted auxetic armor compared to conventional monolithic armor.

6 August 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MAMuhammad Amjad
Muhammad Amjad
SBSaeed Badshah
Saeed Badshah
SASajjad Ahmad
Sajjad Ahmad
MBMujahid Badshah
Mujahid Badshah
SJSakhi Jan
Sakhi Jan
TYTabassam Yasmeen
Tabassam Yasmeen
Total hip arthroplasty (THA) is one of the most successful orthopaedic interventions globally, with over 450,000 procedures annually in the U.S. alone. However, issues like aseptic loosening, dislocation, infection and stress shielding persist, necessitating complex, costly revision surgeries. This highlights the need for continued biomaterials innovation to enhance primary implant integrity and longevity. Implant materials play a pivotal role in determining long-term outcomes, with titanium alloys being the prominent choice. However, emerging evidence indicates scope for optimized materials. The nickel-free β titanium alloy Ti-27Nb shows promise with excellent biocompatibility and mechanical properties. Using finite element analysis (FEA), this study investigated the biomechanical performance and safety factors of a hip bone implant made of nickel-free titanium alloy (Ti-27Nb) under actual loading during routine day life activities for different body weights. The FEA modelled physiological loads during walking, jogging, stair ascent/descent, knee bend, standing up, sitting down and cycling for 75 kg and 100 kg body weights. Comparative analyses were conducted between untreated versus 816-hour simulated body fluid (SBF) treated implant conditions to determine in vivo degradation effects. The FEA predicted elevated von Mises stresses in the implant neck for all activities, especially stair climbing, due to its smaller cross-section. Stresses increased substantially with a higher 100 kg body weight compared to 75 kg, implying risks for heavier patients. Safety factors were reduced by up to 58% between body weights, although remaining above the desired minimum value of 1. Negligible variations were observed between untreated and SBF-treated responses, attributed to Ti-27Nb’s excellent biocorrosion resistance. This comprehensive FEA provided clinically relevant insights into the biomechanical behaviour and integrity of the Ti-27Nb hip implant under complex loading scenarios. The results can guide shape and material optimization to improve robustness against repetitive stresses over long-term use. Identifying damage accumulation and failure risks is crucial for hip implants encountering real-world variable conditions. The negligible SBF effects validate Ti-27Nb’s resistance to physiological degradation. Overall, the study significantly advances understanding of Ti-27Nb’s suitability for reliable, durable hip arthroplasties with low revision rates.