HAZRUL BIN BASRI

Dr. HAZRUL BIN BASRI

UNIVERSITI MALAYSIA SARAWAK (UNIMAS)

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MAMd Ohirul Qays Joarder Akash
Md Ohirul Qays Joarder Akash
Yonis BuswigYonis Buswig
Yonis Buswig
HBHAZRUL BIN BASRI
HAZRUL BIN BASRI
Ahmed Abu-SiadaAhmed Abu-Siada
Ahmed Abu-Siada
Ahmed Abu-SiadaAhmed Abu-Siada
Ahmed Abu-Siada
S.M. MuyeenS.M. Muyeen
S.M. Muyeen
In a photovoltaic (PV)-battery integrated system, the battery undergoes frequent charging and discharging cycles that reduces its operational life and affects its performance considerably. As such, an intelligent power control approach for a PV-battery standalone system is proposed in this paper to improve the reliability of the battery along its operational life. The proposed control strategy works in two regulatory modes: maximum power point tracking (MPPT) mode and battery management system (BMS) mode. The novel controller tracks and harvests the maximum available power from the solar cells under different atmospheric conditions via MPPT scheme. On the other hand, the state of charge (SOC) estimation technique is developed using backpropagation neural network (BPNN) algorithm under BMS mode to manage the operation of the battery storage during charging, discharging, and islanding approaches to prolong the battery lifetime. A case study is demonstrated to confirm the effectiveness of the proposed scheme which shows only 0.082% error for real-world applications. The study discloses that the projected BMS control strategy satisfies the battery-lifetime objective for off-grid PV-battery hybrid systems by avoiding the over-charging and deep-discharging disturbances significantly.

7 June 2017 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
HBHAZRUL BIN BASRI
HAZRUL BIN BASRI
Saad MekhilefSaad Mekhilef
Saad Mekhilef
This study investigates the experimental validation of finite control set–predictive current control (FCS‐PCC) of a multi‐level four‐leg voltage‐source inverter (VSI) operating under balanced and unbalanced conditions. The proposed topology is a combination of conventional four‐leg VSI with an additional four switches circuit serving as dc voltage synthesiser. Unification of both circuits can supply energy to unbalanced three‐phase loads by providing the path for a zero‐sequence load while maintaining appropriate load voltage to the system. The proposed control strategy takes advantage of the discrete nature of the power converter system to predict the future behaviour of the output current. FCS‐PCC is based on an optimal approach that selects the most accurate switching signals among 48 valid switching states by computing cost function and applying switching state that minimises the tracking error to the next sampling time. The proposed control has been experimentally verified to assert the robustness of the control. The prominent outcomes of the experiments confirm the ability of independent load current reference tracking with harmonics distortion lower than the conventional eight switches VSI.

30 October 2017 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
HBHAZRUL BIN BASRI
HAZRUL BIN BASRI
Saad MekhilefSaad Mekhilef
Saad Mekhilef
This study presents an experimental validation and robustness evaluation of predictive current control and reactive power minimisation strategy for a three‐level three‐phase four‐wire indirect matrix converter. The proposed topology features a unification of conventional four‐leg indirect matrix converter with an additional four switches circuit resembling a back‐to‐back buck circuit to synthesise multi‐level variable dual dc‐link voltage. A systematic rectifier switching strategy is elaborated to ensure positive fictitious dc‐link voltage at any instant. The proposed control and topology have been tested under various transient and steady‐state conditions for comprehensive robustness evaluation. The experimental results reveal an outstanding independent load current reference tracking with low ripple current and the reactive power minimisation has been achieved by tuning the weighting factor. The load current tracking and reactive power minimisation have been achieved by properly tuning the weighting factor. The load current harmonics distortion is recorded <5% during normal operating conditions.

30 May 2022 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
HBHAZRUL BIN BASRI
HAZRUL BIN BASRI
Saad MekhilefSaad Mekhilef
Saad Mekhilef
In this paper, a robustness evaluation of model predictive current control with instantaneous reactive power minimization for a three-level four-leg indirect matrix converter is presented. Unbalanced voltages can be extremely dangerous, especially for motors and other inductive equipment. Unbalanced voltages can have a detrimental effect on equipment and the power system, which is exacerbated by the fact that a small phase voltage imbalance can result in a disproportionately large phase current imbalance. The robustness test is carried out by considering balance and unbalanced input voltages. The proposed control predicts the behavior of the load current and the instantaneous reactive power for every possible 96 switching states. Subsequently, it selects the optimum switching state which fulfils the objectives of the control without the need of modulators. The cost function has been adequately modified to consider the asymmetrical aspect of the input voltage. Experimental validation using a laboratory prototype was conducted by using FPGA under a wide range of input voltage unbalance. The experimental results show high fidelity load current reference tracking while maintaining relatively low instantaneous reactive power during the transient and steady-state condition. The percentage of reactive power after setting the optimal weighting factor, the average reactive power was found to reduce to approximately 10-20%.

8 April 2025 in Progress in Engineering Science
Verified
Journal Article
Closed access
YSYiizzan Suffian
Yiizzan Suffian
AHAhmed M.A. Haidar
Ahmed M.A. Haidar
WAWan Awz Abidin
Wan Awz Abidin
HBHAZRUL BIN BASRI
HAZRUL BIN BASRI

9 February 2024 in e-Prime - Advances in Electrical Engineering, Electronics and Energy
Verified
Journal Article
Open access
KLK. Lias
K. Lias
HBHAZRUL BIN BASRI
HAZRUL BIN BASRI
YBY.M.Y. Buswig
Y.M.Y. Buswig
AJAnnisa Jamali
Annisa Jamali
AKA.M.N.A. Kamaruddin
A.M.N.A. Kamaruddin
SSS.K. Sahari
S.K. Sahari