Ivan Dimchev

Dr. Ivan Dimchev

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2025 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
Ivan DimchevIvan Dimchev
Ivan Dimchev
ATAngel Terziev
Angel Terziev
MIMartin Ivanov
Martin Ivanov
MVMomchil Vassilev
Momchil Vassilev
Climate change affects air handling units with two-stage recovery since these systems are used for heating, ventilation and air-conditioning. Their parameters are affected by changes in each of the seasons. The parameters analysed for each of the three climate zones (colder, average and warmer) are SCOP and annual COP of the entire AHU working in all available modes. Two factors - increase in global temperature and increase in CO2 concentration. Each of these factors has a different impact on seasonal coefficient of performance. The increase in global temperature leads to SCOP decrease by 2.3 to 3.7%. On the other hand, the increase of CO2 concentration in the outdoor air for the last 20 years by 50 ppm or 13.3% leads to an increase in SCOP by 5.5 to 6.9%. For the colder climate annual COP is increased by 2.4% due to climate change but for the other two climates (average and warmer) it is decreased with 1.7 and 3.4%. In the near future a large part of the existing air-conditioning and ventilations systems will not be able to maintain the same indoor air quality as now and this will lead to a deterioration in the quality people’s life.

1 August 2025 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
Ivan DimchevIvan Dimchev
Ivan Dimchev
KHKaloyan Hristov
Kaloyan Hristov
District heating systems are hierarchical infrastructures comprising heat generation, distribution, and end-use thermal energy consumption. The heat distribution network is designed to deliver thermal energy reliably and efficiently, in alignment with the specific heating demand profiles of connected end-users. In large-scale district heating systems, supply water temperatures in the distribution pipes can exceed 90 °C during periods of low outdoor air temperatures, while return pipe temperatures typically approach 60 °C. The transportation of thermal energy through the network is inherently associated with heat losses, which are directly influenced by the temperature gradient of the heat transfer fluid and the thermal integrity of the pipe insulation. One approach to mitigating these losses involves lowering the temperature of the heat transfer fluid, which can be achieved using heat pump technologies within the district heat supply infrastructure. Moreover, heat pump systems present a promising pathway for the decarbonization of district heating, enabling the use of heat sources with a low temperature profile.


1 August 2025 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
Ivan DimchevIvan Dimchev
Ivan Dimchev
This article investigates potential strategies to enhance the performance of exhaust air-to-air heat pumps (EAHP) with plate heat exchangers when operating in cooling mode. A critical issue affecting the performance of these systems is inadequate airflow through the heat pump’s condenser, which is integrated within the air handling unit. This airflow limitation results in operational efficiencies that are often equivalent to, or even lower than, those of traditional air handling units equipped with DX coil connected to compressor-condensing units operating under outdoor air conditions. By exploring various optimization approaches, this review aims to identify key factors influencing performance and propose solutions to address this efficiency gap, in order to optimize the energy performance of EAHPs in cooling mode.

5 November 2025
Verified
Conference Paper
Closed access
RARadka Atanasova
Radka Atanasova
MIMartin Ivanov
Martin Ivanov
Ivan DimchevIvan Dimchev
Ivan Dimchev
The presented study deals with the use of fabric ducting in air distribution systems. This is a topic of high relevance as fabric ducting solutions are firmly entering the construction of modern HVAC systems, especially in the context of sustainability, reducing the carbon footprint and the green building construction. The textile materials used, the possibilities for using recycled materials and material innovations are analyzed. Attention is paid to the technological and efficiency challenges in the fabric-based ducting. An example is considered, that compares two identical installations in a public building, used as a sporting goods store in Sofia, Bulgaria. It us done, in order to analyze the effect of changing the material of the air ducts from galvanized steel to textile, in terms of investment costs and energy efficiency, the analysis shows a 27.38% lower investment cost when using fabric ducts. As a result, the use of fabric ducts will reduce energy consumption by 3 918 kWh per year for 3 rooftop HVAC units. Considering that the building is open 365 days a year, 7 days a week and 14 hours a day, the annual energy consumption of the building for the fans alone is 58 079 kWh/year, this means that the reduction of the required energy will be about 6.7%. The calculations from an environmental point of view prove a reduction in carbon emissions by almost 75% when using recycled polyester fabric for the textile ducting.

4 August 2026 in Eng
Verified
Journal Article
Open access
PDF file
Ivan DimchevIvan Dimchev
Ivan Dimchev
Penka ZlatevaPenka Zlateva
Penka Zlateva
Angel K. TerzievAngel K. Terziev
Angel K. Terziev
The use of hydrogen for heating is one of the pathways toward zero-emission buildings. Two possibilities for using hydrogen in combination with heat-pump systems were analyzed: an electrically driven heat pump powered by a fuel cell and a mechanically driven heat pump powered by a hydrogen internal combustion engine (ICE). Heat-pump operation was adapted to local climatic conditions using typical meteorological year datasets for 30 representative locations across Bulgaria. The seasonal coefficient of performance (SCOP) values were further adjusted toward actual operating conditions using a field-performance correction factor. The results reveal a thermodynamic transition between the two pathways, defined by a critical seasonal coefficient of performance, SCOPcrit. For the reference ICE heat-recovery fraction of 0.45 and without direct fuel-cell heat recovery, SCOPcrit is 2.53. Above this threshold, the fuel-cell-driven pathway requires less hydrogen, whereas below it, the mechanically driven pathway requires less hydrogen. A strong correlation was identified between pathway dominance and the mean outdoor temperature during the heating period, with a transition temperature of about 2.4 °C. The sensitivity analysis shows that SCOPcrit ranges between 1.40 and 3.52. Overall system efficiencies ranged from approximately 1.2 to 1.8 on a lower heating value (LHV) basis, exceeding typical direct hydrogen-combustion efficiencies.