José Ignacio Contreras Raggio

Mr. José Ignacio Contreras Raggio

Facultad de Ingeniería y Ciencias, Adolfo Ibáñez University, Santiago, Región Metropolitana, Chile
+1
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2022 in Polymers
Verified
Journal Article
Open access
PDF file
José Ignacio Contreras RaggioJosé Ignacio Contreras Raggio
José Ignacio Contreras Raggio
CACarlos Andrés Toro Arancibia
Carlos Andrés Toro Arancibia
CMCarola Millan
Carola Millan
HPHeidi-Lynn Ploeg
Heidi-Lynn Ploeg
AAAmeet Aiyangar
Ameet Aiyangar
JVJuan F. Vivanco
Juan F. Vivanco
Although the architectural design parameters of 3D-printed polymer-based scaffolds—porosity, height-to-diameter (H/D) ratio and pore size—are significant determinants of their mechanical integrity, their impact has not been explicitly discussed when reporting bulk mechanical properties. Controlled architectures were designed by systematically varying porosity (30–75%, H/D ratio (0.5–2.0) and pore size (0.25–1.0 mm) and fabricated using fused filament fabrication technique. The influence of the three parameters on compressive mechanical properties—apparent elastic modulus Eapp, bulk yield stress σy and yield strain εy—were investigated through a multiple linear regression analysis. H/D ratio and porosity exhibited strong influence on the mechanical behavior, resulting in variations in mean Eapp of 60% and 95%, respectively. σy was comparatively less sensitive to H/D ratio over the range investigated in this study, with 15% variation in mean values. In contrast, porosity resulted in almost 100% variation in mean σy values. Pore size was not a significant factor for mechanical behavior, although it is a critical factor in the biological behavior of the scaffolds. Quantifying the influence of porosity, H/D ratio and pore size on bench-top tested bulk mechanical properties can help optimize the development of bone scaffolds from a biomechanical perspective.

1 April 2021 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
RBRaúl Vallejos Baier
Raúl Vallejos Baier
José Ignacio Contreras RaggioJosé Ignacio Contreras Raggio
José Ignacio Contreras Raggio
CACarlos Andrés Toro Arancibia
Carlos Andrés Toro Arancibia
MBMiguel Arturo Bustamante
Miguel Arturo Bustamante
LPLuis Pérez-Pozo
Luis Pérez-Pozo
JVJuan F. Vivanco
Juan F. Vivanco

3 June 2025 in Polymers
Verified
Journal Article
Open access
PDF file
José Ignacio Contreras RaggioJosé Ignacio Contreras Raggio
José Ignacio Contreras Raggio
MPMiguel Pardo
Miguel Pardo
PNPablo Núñez
Pablo Núñez
CMCarola Millan
Carola Millan
GSGilberto Siqueira
Gilberto Siqueira
AAAmeet Aiyangar
Ameet Aiyangar
Direct ink writing (DIW) is an attractive, extrusion-based, additive manufacturing method for fabricating scaffold structures with controlled porosity using custom composite inks. Polycaprolactone–bioactive glass (PCL-BG) inks have gained attention for bone applications, but optimizing the formulation and fabrication of PCL-BG-based inks for improved printability and desired mechano-biological properties remains a challenge. This study employs a two-step design to systematically evaluate the effect of three factors in terms of PCL-BG composite printability and mechano-biological properties: ink preparation (acetone or dichloromethane (DCM) as the solvent, and mechanical compounding), the extrusion temperature (90 °C, 110 °C, and 130 °C), and the BG content (0%, 10%, and 20% BG). Pure PCL was used as the control. Rheological, calorimetric, and thermo-gravimetric analyses were conducted before printing. Cylindrical scaffolds and solid wells were printed to evaluate the printability, mechanical properties, and cytocompatibility. The scaffold porosity and pore size were carefully examined. Mechanical tests demonstrated that composite formulations with added BG and higher printing temperatures increased the elastic modulus and yield strength. However, PCL-DCM-BG combinations exhibited increased brittleness with higher BG content. Despite concerns about the toxic solvent DCM, the cytocompatibility was comparable to pure PCL for all ink preparation methods. The results suggest that the interaction between the ink preparation solvent, the BG content, and the printing temperature is critical for material design and fabrication planning in bone tissue engineering applications, providing insights into optimizing PCL-BG composite ink formulations for 3D printing in bone tissue engineering.

30 November 2023 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
MDMichael J. Dreyer
Michael J. Dreyer
BWBernhard Weisse
Bernhard Weisse
José Ignacio Contreras RaggioJosé Ignacio Contreras Raggio
José Ignacio Contreras Raggio
RZRobert Zboray
Robert Zboray
William R. TaylorWilliam R. Taylor
William R. Taylor
NHNils Horn
Nils Horn
Analysis of polyethylene (PE) wear in knee implants is crucial for understanding the factors leading to revision in total knee arthroplasty. Importantly, current experimental and computational methods for predicting insert wear can only be validated against true in vivo measurements from retrievals. This study quantitatively investigated in vivo PE wear rates in fixed‐bearing (FB) (n = 21) and rotating‐platform (n = 53) implant retrievals. 3D surface geometry of the retrievals was measured using a structured light scanner. Then, a reference surface that included the deformation, but not the wear that the retrievals had experienced in vivo, was constructed using a fully automatic surface reconstruction algorithm. Finally, wear volume was calculated from the deviation between the worn and reconstructed surfaces. The measurement and analysis techniques were validated and the algorithm was found to produce errors of only 0.2% relative to the component volumes. In addition to quantifying cohort‐level wear rates, the effect of mechanical axis limb alignment on mediolateral wear distribution was examined for a subset of the retrievals (n = 14 + 26). Our results show that FB implants produce significantly (p = 0.04) higher topside wear rates (24.6 ± 10.1 mm3/year) than rotating‐platform implants (15.3 ± 8.0 mm3/year). This effect was larger than that of limb alignment, which had a smaller and nonsignificant influence on overall wear rates (+4.5 ± 11.6 mm3/year, p = 0.43). However, increased varus alignment was associated significantly with greater medial compartment wear in both the FB and rotating‐platform designs (+1.7 ± 1.3%/° and +1.8 ± 1.6%/°). Our findings emphasize the importance of implant design and limb alignment on wear outcomes, providing reference data for improving implant performance and longevity.